PDF Pages PDF Title
8 1 Scope
2 Normative references
3 Terms and definitions
10 4 Constructional requirements
4.1 Heating capacity
4.2 Materials
11 4.3 Combustion chamber
4.4 Filter
4.5 Oil regulator
4.6 Marking of operating settings
4.7 Safety device
4.8 Fan for the supply of combustion air
4.9 Fuel lines
12 4.10 Storage tank
4.11 Oil-level indicator
4.12 Drip tray
4.13 Flue outlet
4.14 Damper
4.15 Draught regulators and combustion air limiters
13 4.16 Assembly
4.17 Maintenance
4.18 Additional requirements for appliances with automatic burners
4.19 Dangerous substances
14 5 Performance and operating requirements
5.1 Maximum oil flow
5.2 Minimum oil flow
5.3 Ignition
5.4 Appliance classes for efficiency and emissions
15 5.5 Smoke number
5.6 Flue gas temperature
5.7 Carbon monoxide content of the flue gas
5.8 Oil temperature
5.9 Floor temperature
5.10 Wall temperature
5.11 Temperature of the control knobs
16 5.12 Draught regulator
5.13 NOX and unburnt hydrocarbons (CnHm) in the flue gases
6 Test methods
6.1 Test apparatus
6.1.1 General
17 6.1.2 Testing of stoves having several possible outlet connections
6.2 Test fuel
18 6.3 Verification of construction
6.4 Testing of leak-tightness of the fuel circuit
6.5 Operational tests
6.5.1 Short-term tests
6.5.1.1 Maximum oil flow rate
19 6.5.1.2 Change from the maximum to the minimum oil flow rate
6.5.1.3 Minimum oil flow rate
6.5.1.4 Change from the minimum to the maximum oil flow rate
20 6.5.1.5 Maximum oil flow rate (Repeat tests)
6.5.2 Long-term tests
6.5.2.1 Maximum oil flow rate
21 6.5.3 Additional tests
6.5.3.1 Intermediate oil flow rates
22 6.5.3.2 Test with burner flooded
6.5.3.3 Stoves fitted with combustion fans
6.5.3.4 Stoves with two burners
6.5.4 Measurement methods
6.5.4.1 Ambient temperature
6.5.4.2 Smoke number and oil derivatives
6.5.4.3 Temperature of the fuel in the storage tank
6.5.4.4 Surface temperatures
6.6 Calculations from the measurements
6.6.1 Efficiency
23 6.6.1.1 Losses of sensible heat in the flue gases
6.6.1.2 Efficiency as a percentage
6.6.2 Heating capacities
6.6.3 Carbon monoxide content of the flue gases
24 6.6.4 NOX in the flue gas
6.6.5 Unburnt hydrocarbons in the flue gas
25 6.6.6 Flue gas mass flow rate
6.6.7 Symbols and units
26 6.7 Test report
27 7 Marking and instructions
7.1 General
7.2 Installation instructions
28 7.3 User operating instructions
29 7.4 Marking
7.5 Documentation for the production
8 Assessment and verification of constancy of performance – AVCP
8.1 General
30 8.2 Type testing
8.2.1 General
8.2.2 Test samples, testing and compliance criteria
31 8.2.3 Test reports
8.2.4 Shared other party results
32 8.2.5 Cascading determination of the product type results
33 8.3 Factory production control (FPC)
8.3.1 General
8.3.2 Requirements
8.3.2.1 General
34 8.3.2.2 Equipment
8.3.2.2.1 Testing
8.3.2.2.2 Manufacturing
8.3.2.2.3 Raw materials and components
35 8.3.2.3 Traceability and marking
8.3.2.4 Controls during manufacturing process
8.3.2.5 Product testing and evaluation
8.3.2.5.1 General
8.3.2.5.2 Product inspection
8.3.2.5.3 Materials and components checks
36 8.3.2.5.4 Manufacturing checks on construction and dimensions
8.3.2.5.5 Other checks
8.3.2.6 Non-complying products
37 8.3.2.7 Corrective action
8.3.2.8 Handling, storage and packaging
8.3.3 Product specific requirements
38 8.3.4 Procedure for modifications
8.3.5 One-off products, pre-production products (e.g. prototypes) and products produced in very low quantity
39 Annex A (normative) Measuring method for determining the smoke number
A.1 Equipment required for the determination of the smoke number
A.1.1 Pump
A.1.2 Sampling tube
A.1.3 Filter paper
A.1.4 Grey scale
A.2 Determination of the smoke number
41 Annex B (normative) Fluid method for detecting oil derivatives
B.1 Equipment required for the detection of oil derivatives
B.1.1 Pump
B.1.2 Sampling tube
B.1.3 Filter paper
B.1.4 Fluid
B.1.5 Sampling
B.1.6 Procedure and evaluation
52 Annex C (normative) Measurement of nitrogen oxides
C.1 General objective and applicability
C.2 General procedure
53 C.3 Measuring principles of analysers
C.3.1 Chemoluminiscence method
54 C.3.2 Non-dispersive infrared (NDIR) method
55 Annex D (normative) Measurement of total hydrocarbons (THC)
D.1 General objective and applicability
D.2 General procedure
D.3 Equipment
56 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Directive
ZA.1 Scope and relevant characteristics
57 ZA.2 Procedure for AVCP of flued oil stoves with vaporizing burners
ZA.2.1 System(s) of AVCP
58 ZA.2.2 Declaration of performance (DoP)
ZA.2.2.1 General
ZA.2.2.2 Content
59 ZA.2.2.3 Example of DoP
62 ZA.3 CE marking and labelling
BSI 13/30277394 DC