ISO 16889:2022
$44.85
Hydraulic fluid power – Filters – Multi-pass method for evaluating filtration performance of a filter element
Published By | Publication Date | Number of Pages |
ISO | 2022-01 | 50 |
This document describes the following:
āĀ Ā Ā a multi-pass filtration performance test with continuous contaminant injection for hydraulic fluid power filter elements;
NOTE 1Ā Ā For the background interlaboratory study used to verify the test methodology, see AnnexĀ D.
āĀ Ā Ā a procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics;
āĀ Ā Ā a test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes =Ā 25Ā Āµm(c), and a final reservoir gravimetric level of less than 200Ā mg/L;
NOTE 2Ā Ā It is necessary to determine by validation the range of flow rates and the lower particle size limit that can be used in test facilities.
āĀ Ā Ā a test using ISO medium test dust (ISO MTD) contaminant and a test fluid in accordance with AnnexĀ A.
This document is intended to provide a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge.
This document applies to three test conditions:
āĀ Ā Ā test conditionĀ 1, with a base upstream gravimetric level of 3Ā mg/L;
āĀ Ā Ā test conditionĀ 2, with a base upstream gravimetric level of 10Ā mg/L;
āĀ Ā Ā test conditionĀ 3, with a base upstream gravimetric level of 15Ā mg/L.