{"id":253283,"date":"2024-10-19T16:43:49","date_gmt":"2024-10-19T16:43:49","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60320-12015-2\/"},"modified":"2024-10-25T12:04:51","modified_gmt":"2024-10-25T12:04:51","slug":"bs-en-60320-12015-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60320-12015-2\/","title":{"rendered":"BS EN 60320-1:2015"},"content":{"rendered":"
This part of lEC 60320 sets the general requirements for appliance couplers for two poles and two poles with earth contact and for the connection of electrical devices for household and similar onto the mains supply.<\/p>\n
This part of lEC 60320 is also valid for appliance inlets\/appliance outlets integrated or incorporated in appliances.<\/p>\n
The rated voltage does not exceed 250 V (a.c.) and the rated current does not exceed 16 A.<\/p>\n
Appliance couplers complying with this part of lEC 60320 are suitable for normal use at ambient temperatures not normally exceeding +40 \u00b0C, but their average over a period of 24 h does not exceed +35 \u00b0C, with a lower limit of the ambient air temperature of \u20135 \u00b0C.<\/p>\n
Appliance couplers are not suitable for<\/p>\n
use in place of plug and socket-outlet systems according to IEC 60884-1.<\/p>\n<\/li>\n
use in place of devices for connecting luminaires (DCLs) according to IEC 61995 or luminaire supporting couplers (LSCs).<\/p>\n<\/li>\n<\/ul>\n
\nNOTE Requirements for d.c. are under consideration.<\/p>\n<\/blockquote>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n National foreword <\/td>\n<\/tr>\n \n 4<\/td>\n European foreword
Endorsement notice <\/td>\n<\/tr>\n\n 7<\/td>\n CONTENTS <\/td>\n<\/tr>\n \n 11<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 13<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 14<\/td>\n 3 Terms and definitions <\/td>\n<\/tr>\n \n 15<\/td>\n Figures
Figure 1 \u2013 Intended use of appliance couplers <\/td>\n<\/tr>\n\n 17<\/td>\n 4 General requirements <\/td>\n<\/tr>\n \n 18<\/td>\n 5 General notes on tests
5.1 General
5.2 Test samples
5.3 Failures
5.4 Routine tests <\/td>\n<\/tr>\n\n 19<\/td>\n 6 Standard ratings
7 Classification of appliance couplers
8 Marking
8.1 General
8.2 Additional markings <\/td>\n<\/tr>\n\n 20<\/td>\n 8.3 Appliance couplers for class II equipment
8.4 Symbols or alphanumeric notations
8.5 Legibility of markings
8.6 Terminal markings and wiring instructions <\/td>\n<\/tr>\n\n 21<\/td>\n 8.7 Durability
8.8 Test and inspection
9 Dimensions and compatibility
9.1 General
9.2 Single\u2010pole connections
9.3 Compatibility <\/td>\n<\/tr>\n\n 22<\/td>\n 9.4 Dimensions for standardized appliance couplers
9.5 Dimensions for non-standardized appliance couplers
10 Protection against electric shock
10.1 Accessibility of live parts <\/td>\n<\/tr>\n\n 23<\/td>\n 10.2 Protection against single pole connection
10.3 Protection against access to live parts
10.4 External parts
10.5 Shrouds
11 Provision for earthing
12 Terminals and terminations
12.1 General <\/td>\n<\/tr>\n\n 24<\/td>\n 12.2 Rewirable appliance couplers
12.3 Non\u2010rewirable appliance couplers
13 Construction
13.1 Risk of accidental contact
13.2 Contact positions
13.3 Parts covering live parts
Tables
Table 1 \u2013 Position of contacts <\/td>\n<\/tr>\n\n 25<\/td>\n 13.4 Pin construction
13.4.1 Prevention of rotation
13.4.2 Pin retention
13.4.3 Non\u2010solid pins <\/td>\n<\/tr>\n\n 26<\/td>\n 13.5 Contact pressure
13.6 Enclosure
13.6.1 General
13.6.2 Rewirable connectors\/plug connectors
Figure 2 \u2013 Device for testing non-solid pins <\/td>\n<\/tr>\n\n 27<\/td>\n 13.6.3 Non-rewirable connectors\/plug connectors
13.7 Earth connection <\/td>\n<\/tr>\n\n 28<\/td>\n 13.8 Location of terminals and terminations
13.8.1 General
13.8.2 Free wire test for rewirable accessories
13.8.3 Free wire test for non-rewirable non-moulded-on accessories <\/td>\n<\/tr>\n\n 29<\/td>\n 13.8.4 Free wire verification for non-rewirable moulded-on accessories
13.9 Connectors\/plug connectors without earthing contact
13.10 Fuses, relays, thermostats, thermal cut-outs and switches
14 Moisture resistance <\/td>\n<\/tr>\n\n 30<\/td>\n 15 Insulation resistance and electric strength
15.1 General <\/td>\n<\/tr>\n\n 31<\/td>\n 15.2 Insulation resistance
Table 2 \u2013 Maximum diameters of the cords <\/td>\n<\/tr>\n\n 32<\/td>\n 15.3 Dielectric strength
Table 3 \u2013 Minimum insulation resistance
Table 4 \u2013 Dielectric strength <\/td>\n<\/tr>\n\n 33<\/td>\n 16 Forces necessary to insert and to withdraw the connector\/appliance outlet
16.1 General
16.2 Verification of the maximum withdrawal force
Table 5 \u2013 Maximum and minimum withdrawal forces <\/td>\n<\/tr>\n\n 34<\/td>\n Figure 3 \u2013 Apparatus for checking the withdrawal force <\/td>\n<\/tr>\n \n 35<\/td>\n 16.3 Verification of the minimum withdrawal force
Figure 4 \u2013 Gauge for verification of the minimum withdrawal force <\/td>\n<\/tr>\n\n 36<\/td>\n 17 Operation of contacts
18 Resistance to heating of appliance couplers for hot conditions or very hot conditions
18.1 General
18.2 Heating test for connectors\/plug connectors <\/td>\n<\/tr>\n\n 37<\/td>\n 18.3 Heating test for appliance inlets\/appliance outlets
19 Breaking capacity <\/td>\n<\/tr>\n\n 38<\/td>\n Figure 5 \u2013 Circuit diagram for breaking capacity and normal operation tests
Table 6 \u2013 Ratings for the tests of Clause 19 <\/td>\n<\/tr>\n\n 39<\/td>\n 20 Normal operation
21 Temperature rise
Table 7 \u2013 Ratings for the tests of Clause 20 <\/td>\n<\/tr>\n\n 40<\/td>\n 22 Cords and their connection
22.1 Cords for non-rewirable connectors\/plug connectors
Table 8 \u2013 Cords and conductors for the tests of Clause 21 <\/td>\n<\/tr>\n\n 41<\/td>\n 22.2 Cord anchorage
22.2.1 General
22.2.2 Additional requirements for rewirable connectors\/plug connectors
Table 9 \u2013 Type and nominal cross-sectional area of cords <\/td>\n<\/tr>\n\n 42<\/td>\n 22.2.3 Pull test for cable anchorage
Figure 6 \u2013\u00a0Apparatus for testing the cord anchorage <\/td>\n<\/tr>\n\n 43<\/td>\n Table 10 \u2013 Types of cord for the rewirable connector\/plug connector test <\/td>\n<\/tr>\n \n 44<\/td>\n 22.3 Flexing test <\/td>\n<\/tr>\n \n 45<\/td>\n Figure 7 \u2013\u00a0Apparatus for the flexing test <\/td>\n<\/tr>\n \n 46<\/td>\n 23 Mechanical strength
23.1 General <\/td>\n<\/tr>\n\n 47<\/td>\n 23.2 Free fall test
23.3 Lateral pull test <\/td>\n<\/tr>\n\n 48<\/td>\n Figure 8 \u2013 Example of apparatus for pulling test <\/td>\n<\/tr>\n \n 49<\/td>\n 23.4 Impact test
23.5 Deformation test
Table 11 \u2013 Values for the lateral pulls applied <\/td>\n<\/tr>\n\n 50<\/td>\n 23.6 Torque and pull test
24 Resistance to heat and ageing
24.1 Resistance to heat
Table 12 \u2013 Values for torque and pull forces <\/td>\n<\/tr>\n\n 51<\/td>\n 24.2 Resistance to ageing
24.2.1 General
24.2.2 Ageing test for elastomeric materials
24.2.3 Ageing test for thermoplastic materials
24.2.4 Ageing test assessment <\/td>\n<\/tr>\n\n 52<\/td>\n 25 Screws, current-carrying parts and connections
25.1 General <\/td>\n<\/tr>\n\n 53<\/td>\n 25.2 Electrical connections
25.3 Securement of connections
25.4 Metallic parts
Table 13 \u2013 Torque applied for the tightening and loosening test <\/td>\n<\/tr>\n\n 54<\/td>\n 26 Clearances, creepage distances and solid insulation
26.1 General
26.2 Clearances
26.2.1 Dimensioning <\/td>\n<\/tr>\n\n 55<\/td>\n 26.2.2 Minimum values for clearances
Table 14 \u2013 Rated impulse withstand voltage for appliance couplersenergized directly from the low voltage mains <\/td>\n<\/tr>\n\n 56<\/td>\n 26.3 Creepage distances
26.3.1 Dimensioning
26.3.2 Minimum creepage distances
Table 15 \u2013 Minimum clearances for basic insulation <\/td>\n<\/tr>\n\n 57<\/td>\n 26.4 Solid insulation
Table 16 \u2013 Minimum creepage distances for basic and functional insulation <\/td>\n<\/tr>\n\n 58<\/td>\n 27 Resistance of insulating material to heat, fire and tracking
27.1 Resistance to heat and fire
27.1.1 General
27.1.2 Object of the test
27.1.3 General description of the test
27.1.4 Description of test apparatus
27.1.5 Degree of severity <\/td>\n<\/tr>\n\n 59<\/td>\n 27.1.6 Verification of the thermocouple
27.1.7 Preconditioning
27.1.8 Initial measurements
27.1.9 Test procedure
27.1.10 Observations and measurements
27.1.11 Evaluation of test results
27.2 Resistance to tracking
28 Resistance to rusting <\/td>\n<\/tr>\n\n 60<\/td>\n 29 Electromagnetic compatibility (EMC) requirements
29.1 Immunity \u2013 Accessories not incorporating electronic components
29.2 Emission \u2013 Accessories not incorporating electronic components <\/td>\n<\/tr>\n\n 61<\/td>\n Annexes
Annex A (normative) Proof tracking test <\/td>\n<\/tr>\n\n 62<\/td>\n Annex B (normative) Routine tests for factory wired appliance couplers related to safety
B.1 General
B.2 Polarized systems: Phase (L) and neutral (N) \u2013 Correct connection
Table B.1 \u2013 Test overview <\/td>\n<\/tr>\n\n 63<\/td>\n B.3 Earth (PE) continuity
B.4 Short-circuit\/wrong connection and reduction in creepage distance and clearance
B.4.1 Accessible surface safety check
B.4.2 Short-circuit\/wrong connection <\/td>\n<\/tr>\n\n 64<\/td>\n Annex C (normative) Test schedule
Table C.1 \u2013 Test schedule <\/td>\n<\/tr>\n\n 66<\/td>\n Annex D (informative) Comparison of typical conductor cross-sectional areas
Table D.1 \u2013 Comparison of conductor sizes <\/td>\n<\/tr>\n\n 67<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Appliance couplers for household and similar general purposes – General requirements<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2019<\/td>\n 68<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":253289,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[509,2641],"product_tag":[],"class_list":{"0":"post-253283","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-120-30","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/253283","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/253289"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=253283"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=253283"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=253283"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}