{"id":258439,"date":"2024-10-19T17:06:32","date_gmt":"2024-10-19T17:06:32","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-20794-22020\/"},"modified":"2024-10-25T12:44:02","modified_gmt":"2024-10-25T12:44:02","slug":"bs-iso-20794-22020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-20794-22020\/","title":{"rendered":"BS ISO 20794-2:2020"},"content":{"rendered":"
This document describes the application layer protocol including the application measurement and control data management, message transfer and fault management.<\/p>\n
The application and application layer contain the following descriptions:<\/p>\n
message structure;<\/p>\n<\/li>\n
communication method;<\/p>\n<\/li>\n
network management (optional);<\/p>\n<\/li>\n
measurement and control data; and<\/p>\n<\/li>\n
error handling.<\/p>\n<\/li>\n<\/ul>\n
This document also specifies:<\/p>\n
the service interface; and<\/p>\n<\/li>\n
the service interface parameters.<\/p>\n<\/li>\n<\/ul>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4 Symbols and abbreviated terms 4.1 Symbols 4.2 Abbreviated terms <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5 Conventions 6 Introduction to application and application layer 6.1 Application properties 6.2 Application layer properties 6.3 Message transmission 6.4 Communication methods <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 6.5 Message types 6.6 Error handling 7 Service interface parameters (SIP) 7.1 SIP \u2014 General 7.2 SIP \u2014 Data type definitions <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 7.3 SIP \u2014 Mtype, message type 7.4 SIP \u2014 ReqId, request identifier 7.5 SIP \u2014 ReqTypeId, request type identifier 7.6 SIP \u2014 PDU, protocol data unit 7.7 SIP \u2014 Length, length of PDU 7.8 SIP \u2014 ev_wakeup_ind, event wake-up indication (optional) <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 7.9 SIP \u2014 cmd_wakeup_req, command wake-up request 7.10 SIP \u2014 NMInfo, network management information <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 7.11 SIP \u2014 SCT, sequence count 7.12 SIP \u2014 Result, result 8 SI \u2014 Service interface (SI) definition to application and lower OSI layers 8.1 SI \u2014 A_Data.req and A_Data.ind service interface <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 8.2 SI \u2014 A_Data.req and A_Data.ind service interface parameter mapping 9 Application (APP) 9.1 APP \u2014 Message exchange 9.2 APP \u2014 Communication methods 9.2.1 APP \u2014 General <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 9.2.2 APP \u2014 Event-triggered method 9.2.3 APP \u2014 Polling method <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 9.3 APP \u2014 Network management (NM) 9.3.1 APP \u2014 General <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 9.3.2 APP \u2014 Normal, standby, and sleep states <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 9.3.3 APP \u2014 Normal state <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 9.3.4 APP \u2014 Sleep state (optional) 9.3.5 APP \u2014 Standby state (optional) 9.3.6 APP \u2014 Wake-up\/sleep function (optional) <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 9.3.7 APP \u2014 Wake-up\/sleep sequence parameter 9.4 APP \u2014 Multi clock master sequence processing <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 9.5 APP \u2014 Measurement and\/or control data 9.5.1 APP \u2014 Publisher and subscriber data <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 9.5.2 APP \u2014 Measurement and\/or control data management 9.5.3 APP \u2014 Measurement and\/or control data types 9.5.4 APP \u2014 Measurement and\/or control data consistency <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 9.5.5 APP \u2014 Assignment of ReqId 9.5.6 APP \u2014 Priority of ReqId <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 9.6 APP \u2014 Error handling 9.6.1 APP \u2014 General 9.6.2 APP \u2014 CXPI network error <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 9.6.3 APP \u2014 Network management information <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 9.6.4 APP \u2014 SCT, sequence count (optional) <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 9.6.5 APP \u2014 Sequence count (SCT) error (optional) 9.6.6 APP \u2014 Transmission prohibition <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 9.6.7 APP \u2014 Retransmission 9.6.8 APP \u2014 Error notification on CXPI network (optional) <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 10 Application layer (AL) 10.1 AL \u2014 Message exchange <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 10.2 AL \u2014 Message structure <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 10.3 AL \u2014 Request protected type identifier field 10.4 AL \u2014 Request protected identifier field 10.4.1 AL \u2014 General 10.4.2 AL \u2014 Judgment of received message 10.5 AL \u2014 Response field (A_PDU) 10.5.1 AL \u2014 General 10.5.2 AL \u2014 A_PDU <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 10.5.3 AL \u2014 Wake-up indication and request 10.6 AL \u2014 Error detection <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Road vehicles. Clock extension peripheral interface (CXPI) – Application layer<\/b><\/p>\n |