{"id":26015,"date":"2024-10-17T00:35:54","date_gmt":"2024-10-17T00:35:54","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/nfpa-53-2011\/"},"modified":"2024-10-24T13:43:44","modified_gmt":"2024-10-24T13:43:44","slug":"nfpa-53-2011","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/nfpa\/nfpa-53-2011\/","title":{"rendered":"NFPA 53 2011"},"content":{"rendered":"
Control hazards to protect lives and property with the 2011 NFPA 53: Recommended Practice on Materials, Equipment, and Systems Used in Oxygen-Enriched Atmospheres.<\/em><\/strong><\/p>\n The 2011 NFPA 53<\/em> is your single-source for the latest criteria for the safe use of oxygen (liquid\/gaseous) and the design of systems for use in oxygen and oxygen-enriched atmospheres (OEAs). Information is provided for the selection of materials, components, and design criteria that can be used safely in oxygen and OEAs.<\/p>\n Applications of NFPA 53<\/em> include:<\/strong><\/p>\n This document also provides actual reports of fire experience in OEAs<\/p>\n Recommended Practice on Materials, Equipment, and Systems Used in Oxygen-Enriched Atmospheres<\/b><\/p>\n\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n Important Notices and Disclaimers
Important Notices and Disclaimers <\/td>\n<\/tr>\n\n 3<\/td>\n Additional Notices and Disclaimers
Additional Notices and Disclaimers <\/td>\n<\/tr>\n\n 4<\/td>\n 2.1 General
2.1 General
2.2 NFPA Publications
2.2 NFPA Publications <\/td>\n<\/tr>\n\n 7<\/td>\n Chapter 1 Administration
Chapter 1 Administration
1.1 Scope
1.1 Scope
1.2 Purpose
1.2 Purpose
1.3 Application
1.3 Application
1.4 Interpretations
1.4 Interpretations
Chapter 2 Referenced Publications
Chapter 2 Referenced Publications
2.3 Other Publications
2.3 Other Publications <\/td>\n<\/tr>\n\n 8<\/td>\n 2.4 References for Extracts in Recommendations Sections
2.4 References for Extracts in Recommendations Sections
Chapter 3 Definitions
Chapter 3 Definitions
3.1 General
3.1 General
3.2 NFPA Official Definitions
3.2 NFPA Official Definitions
3.3 General Definitions
3.3 General Definitions <\/td>\n<\/tr>\n\n 9<\/td>\n Chapter 4 Types of Systems Used in Oxygen-Enriched Atmospheres
Chapter 4 Types of Systems Used in Oxygen-Enriched Atmospheres
4.1 General
4.1 General
Chapter 5 Materials Selection
Chapter 5 Materials Selection
5.1 General
5.1 General <\/td>\n<\/tr>\n\n 10<\/td>\n 5.2 Nonmetals
5.2 Nonmetals
5.3 Metals
5.3 Metals
Chapter 6 Component Selection
Chapter 6 Component Selection
6.1 Material Recommendations
6.1 Material Recommendations
6.2 General Design Recommendations
6.2 General Design Recommendations
6.3 Specific Component Design Guidelines
6.3 Specific Component Design Guidelines <\/td>\n<\/tr>\n\n 11<\/td>\n 6.4 Components
6.4 Components
Chapter 7 System Design
Chapter 7 System Design
7.1 Design Considerations
7.1 Design Considerations
7.2 Worst-Case Conditions
7.2 Worst-Case Conditions
7.3 Fire-Stopping Techniques
7.3 Fire-Stopping Techniques <\/td>\n<\/tr>\n\n 12<\/td>\n 7.4 Personnel Qualifications
7.4 Personnel Qualifications
7.5 Oxygen Transmission
7.5 Oxygen Transmission
7.6 Shutoff
7.6 Shutoff
7.7 Electrical Equipment
7.7 Electrical Equipment
7.8 Cleaning for Oxygen Service
7.8 Cleaning for Oxygen Service
7.9 Combustibles
7.9 Combustibles
7.10 Applicable Standards
7.10 Applicable Standards <\/td>\n<\/tr>\n\n 13<\/td>\n Chapter 8 Fire Extinguishment
Chapter 8 Fire Extinguishment
8.1 Oxygen Supply
8.1 Oxygen Supply
8.2 Extinguishing Systems
8.2 Extinguishing Systems
8.3 Fixed Systems
8.3 Fixed Systems
8.4 Water Hose
8.4 Water Hose
8.5 Diluents
8.5 Diluents
8.6 Limiting Fire Spread
8.6 Limiting Fire Spread
8.7 Nontoxic Agents
8.7 Nontoxic Agents
8.8 Wetting
8.8 Wetting
8.9 Instructions and Drills
8.9 Instructions and Drills
Annex A Explanatory Material
Annex A Explanatory Material <\/td>\n<\/tr>\n\n 17<\/td>\n Annex B Training and Education
Annex B Training and Education
Annex C Utilization of Oxygen-Enriched Atmospheres
Annex C Utilization of Oxygen-Enriched Atmospheres <\/td>\n<\/tr>\n\n 21<\/td>\n Annex D Fire Experience
Annex D Fire Experience <\/td>\n<\/tr>\n\n 30<\/td>\n Annex E Fundamentals of Ignition and Combustion in Oxygen-Enriched Atmospheres
Annex E Fundamentals of Ignition and Combustion in Oxygen-Enriched Atmospheres <\/td>\n<\/tr>\n\n 35<\/td>\n Annex F Materials for Use in Oxygen-Enriched Atmospheres
Annex F Materials for Use in Oxygen-Enriched Atmospheres <\/td>\n<\/tr>\n\n 54<\/td>\n Annex G Informational References
Annex G Informational References <\/td>\n<\/tr>\n\n 56<\/td>\n Index
Index <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n NFPA<\/b><\/a><\/td>\n 2011<\/td>\n 60<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":26016,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2638],"product_tag":[],"class_list":{"0":"post-26015","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-nfpa","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/26015","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/26016"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=26015"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=26015"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=26015"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}