{"id":416703,"date":"2024-10-20T06:12:11","date_gmt":"2024-10-20T06:12:11","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-501872022-tc\/"},"modified":"2024-10-26T11:31:32","modified_gmt":"2024-10-26T11:31:32","slug":"bs-en-501872022-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-501872022-tc\/","title":{"rendered":"BS EN 50187:2022 – TC"},"content":{"rendered":"
This document applies to pressurized gas-filled compartments of AC switchgear and controlgear with rated voltages above 1 kV and up to and including 52 kV for indoor or outdoor installations, where the gas or gas mixture is being used principally for its dielectric and\/or arc-quenching properties and where the gases or gas mixtures in the compartment can be considered in conditions being chemically stable over its lifetime and non-corrosive to the material of the pressurized compartment in the conditions that prevail inside.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 30466326 <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | A-30427220 <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 4 Normal and special service conditions 5 Design and construction 5.1 General 5.2 Materials 5.3 Corrosion allowance 5.4 Manholes and inspection openings 5.5 Design pressure 5.6 Design temperature <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 5.7 Design of compartments 5.7.1 General 5.7.2 Calculation methods <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 5.8 Pressure relief devices 6 Manufacturing and workmanship 7 Quality assurance 8 Inspection and testing 8.1 Type tests 8.1.1 General <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 8.1.2 Pressure withstand test for gas-filled compartments with pressure relief devices 8.1.3 Pressure withstand test for gas-filled compartments without pressure relief devices <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 8.2 Routine tests 9 Certification and marking 9.1 Design specification, drawings and data sheets 9.2 Certificates 9.3 Marking 9.4 Final Inspection 10 Transport <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Annex A (informative)A-deviations <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. High-voltage switchgear and controlgear. Gas-filled compartments of AC switchgear and controlgear with rated voltages above 1 kV up to and including 52 kV<\/b><\/p>\n |