{"id":80389,"date":"2024-10-17T18:43:50","date_gmt":"2024-10-17T18:43:50","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c37-14-1999\/"},"modified":"2024-10-24T19:43:21","modified_gmt":"2024-10-24T19:43:21","slug":"ieee-c37-14-1999","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c37-14-1999\/","title":{"rendered":"IEEE C37.14 1999"},"content":{"rendered":"
Revision Standard – Inactive – Superseded. Superseded by C37.14-2002 This standard covers enclosed low-voltage dc power circuit breakers of the stationary or draw-out type of single- or two-pole construction with one or more rated maximum voltages of 300 V, 325 V, 800 V, 1200 V, 1600 V, or 3200 V for applications on dc systems having nominal voltages of 250 V, 275 V, 750 V, 1000 V, 1500 V, or 3000 V, with general-purpose, high-speed, semi-high-speed and rectifier circuit breakers; manually or power-operated; and with or without electro-mechanical or electronic trip devices. It deals with service conditions, ratings, functional components, temperature limitations and classification of insulating materials, dielectric withstand voltage requirements, test procedures, and application.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Title Page <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1. Scope 2. References <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 3. Definitions <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 4. Service conditions 5. Ratings 5.1 Rating information 5.2 Rated maximum voltage 5.2 Rated continuous current <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 5.4 Rated peak current 5.5 Rated short-time current 5.6 Rated short-circuit current 5.7 Rated-control voltage <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 6. Functional components <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 6.1 Nameplate(s) 6.2 Contact position indicator 6.3 Stored energy indicator 6.4 Locking 7. Temperature limitations and classification of insulating materials 7.1 Temperature limits 7.2 Limits of observable temperature rise <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 7.3 Classification of insulating materials 8. Dielectric withstand voltage requirements 8.1 Test values <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 8.2 Test procedures 9. Test requirements 9.1 Classification of tests <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 9.2 Schedule of design tests <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 9.3 Treatment of failures within a test sequence 9.4 Production tests <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 10. Application guide 10.1 Scope 10.2 General <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 10.3 Limiting transient arc voltage <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 10.4 Application limitations relating to mechanism types 10.5 Service conditions affecting circuit breaker applications <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 10.6 Application of general-purpose dc low-voltage power circuit breakers to motor starting and running duty 10.7 Repetitive duty operations and normal maintenance <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 10.8 Application of circuit breakers without enclosures <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Annex A\u2014Technical application guide <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard for Low-Voltage DC Power Circuit Breakers Used in Enclosures<\/b><\/p>\n |