AS/NZS 61459:2000

$33.80

Low-voltage fuses – Coordination between fuses and contactors/motor-starters – Application guide

Published By Publication Date Number of Pages
AS 2000-12-06 22
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Provides guidance to assist in selecting a fuse-link to ensure coordination with contactors or motor-starters (contactors with overload relay). This Standard is identical with and is reproduced from IEC 61459:1996.

Scope

The information given in this technical report provides guidance to assist in selecting a fuse-link to ensure coordination with contactors or motor-starters (contactors with overload relay).
The coordination between motor-starters and the fuses which protect them is covered in IEC standards by test requirements such as those in IEC 60947, in particular parts 1 and 4.
Overcurrent protection of other equipment, such as motors, conductors, etc., is not covered by this technical report.
Tests are specified at three levels of prospective current, according to IEC 60947-4-1:
a) in the region of the current Ic (see clause 5). Tests are made at 0,75Ic when the
starter shall disconnect the current without damage and the fuse does not operate, and at 1,25 Ic when the fuse shall operate before the starter (see annex A, figure A.1);
b) at the appropriate value of prospective current "r" shown in IEC 60947-4-1, table XI (see table A.1 in annex A);
c) at the rated conditional short-circuit current Iq, if higher than the test current "r".
The fuse selected is capable of absorbing the surge of current on starting the motor and is normally selected from the recommendations of the manufacturer or by compliance with national installation codes and wiring rules.
Studies carried out by IEC committee "Fuses" in collaboration with motor-starter manufacturers worldwide have revealed that there is no major difficulty in achieving satisfactory coordination at the most exacting of the levels of type of coordination using selected fuses according to IEC 60269-2 in coordination with modern contactors. A survey is presented in annex B of the rated currents, I²t values and cut-off currents of fuses correctly chosen according to the ratings of the starters they protect, based on the results of successful type testing throughout the world.
Examples of suitable fuse-links used for motor protection are also given in annex B.