ASME BPVC IV 2017
$377.00
ASME BPVC – IV -2017 BPVC Section IV, Rules for Construction of Heating Boilers
Published By | Publication Date | Number of Pages |
ASME | 2017 | 305 |
None
PDF Catalog
PDF Pages | PDF Title |
---|---|
56 | HG-307 Some Acceptable Types of Unstayed Flat Heads and Covers |
60 | HG-309 Spherically Dished Steel Plate Covers With Bolting Flanges |
62 | HG-312.4 Acceptable Type of Ring-Reinforced Furnace |
63 | HG-312.7 Connection Between Plain and Corrugated Furnace |
64 | HG-312.8 Acceptable Type of Semicircular Furnace Reinforcement |
66 | HG-321 Chart for Determining Values of F HG-321 Values of Spherical Radius Factor K1 |
68 | HG-326.1 Some Representative Configurations Describing the Reinforcement Dimension, te, and the Finished Opening Dimension, d |
69 | HG-326.2 Nomenclature and Formulas for Reinforced Openings |
72 | HG-340.1 Pitch of Staybolts Adjacent to Upper Corners of Fireboxes HG-340.2 Acceptable Proportions for Ends of Through‐Stays HG-340.3 Examples of Acceptable Corner Welds for Pressures Not Over 30 psi |
74 | HG-340 Allowable Pitch of Stays, in. (mm) (Limited by HG-340.3) |
75 | HG-343 Details of Installation of Diagonal Stays |
77 | HG-345.1(a) Sketch Showing Application of HG-345.1 to the Staying of Boilers |
78 | HG-345.1(b) Sketch Showing Application of HG-345.1 to the Staying of Boilers |
79 | HG-350.1 Example of Tube Spacing With Pitch of Holes Equal in Every Row HG-350.2 Example of Tube Spacing With Pitch of Holes Unequal in Every Second Row |
80 | HG-350.3 Example of Tube Spacing With Pitch of Holes Varying in Every Second and Third Row HG-350.4 Example of Tube Spacing With Tube Holes on Diagonal Lines |
81 | HG-360 Permitted O‐Ring Materials HG-370 Minimum Thickness of Material for Threaded Connections to Boilers |
85 | HG-402 Official Certification Mark to Denote the American Society of Mechanical Engineers’ Standard |
94 | HG-530.1 Official Certification Mark to Denote the American Society of Mechanical Engineers’ Standard |
95 | HG-530.2 Steam and Water Boilers Form of Marking on Completed Boilers or Their Nameplates |
96 | HG-530.3 Boilers Suitable for Water Only HG-530.4 Steam and Water Boilers |
97 | HG-530.5 Boilers Suitable for Water Only HG-530.6 Boilers Suitable for Water Only HG-530.7 Steam and Water Boilers |
98 | HG-530.8 Boilers Suitable for Water Only |
107 | HG-703.1(a) Steam Boilers in Battery — Pumped Return — Acceptable Piping Installation |
108 | HG-703.1(b) Steam Boilers in Battery — Gravity Return — Acceptable Piping Installation |
109 | HG-703.2 Hot Water Boilers in Battery — Acceptable Piping Installation |
111 | HG-709.2 Expansion Tank Capacities for Forced Hot Water Systems |
112 | HG-715 Size of Bottom Blowoff Piping, Valves, and Cocks |
113 | HG-725(a) Spacing and Weld Details for Supporting Lugs in Pairs on Horizontal‐Return Tubular Boiler |
114 | HG-725(b) Welded Bracket Connection for Horizontal‐Return Tubular Boiler |
121 | HF-300.1 Maximum Allowable Stress Values for Ferrous Materials, ksi |
128 | HF-300.1M Maximum Allowable Stress Values for Ferrous Materials, MPa |
136 | HF-300.2 Maximum Allowable Stress Values for Nonferrous Materials, ksi |
141 | HF-300.2M Maximum Allowable Stress Values for Nonferrous Materials, MPa |
149 | HW-701.1 Butt Welding of Plates of Unequal Thickness |
151 | HW-701.3 Some Forms of Attachments of Pressure Parts to Flat Plates to Form a Corner Joint (Tee Joint) |
152 | HW-710.4(a) Some Acceptable Types of Diagonal Stays for Installation by Welding HW-710.4(b) Unacceptable Types of Diagonal Stays for Installation by Welding |
154 | HW-715.1 Heads Attached to Shells HW-713 Firetube Extension Through Tubesheets for Welded Construction |
156 | HW-731 Some Acceptable Types of Welds for Fittings, Nozzles, and Other Connections to Shells, Drums, and Headers |
159 | HW-740 Three‐Ply Joint Assemblies |
161 | HW-745 Two‐Ply Joint Assemblies |
171 | HB-1305 Recommended Joint Clearances at Brazing Temperature |
176 | HC-204.1 Dimensions of Tensile Test Specimen HC-205.1 Cast Test Bars |
178 | HC-212 Correction Factors for Transverse Test Bars HC-214 Pipe Plug Size for Minimum Wall Thickness |
180 | HC-300 Maximum Allowable Stress Values in Tension for Cast Iron, ksi (MPa) |
181 | HC-311 Spherically Shaped Covers With Bolting Flanges |
206 | HLW-300 Maximum Allowable Stress Values in Tension for Lined Water Heater Materials, ksi (MPa) |
208 | HLW-301 Maximum Allowable Stress Values in Tension for Unlined Water Heater Materials, ksi (MPa) |
212 | HLW-401.1 Butt Welding of Plates of Unequal Thickness |
213 | HLW-401.2 Typical Corner Joints HLW-401.3-1 Alignment Tolerance |
215 | HLW-411 Typical Water Heater Welded Joints |
217 | HLW-413 Tubes Attached by Welding |
218 | HLW-415 Heads Attached to Shells |
220 | HLW-431.1 Some Acceptable Types of Welds for Fittings, Nozzles, and Other Connections to Shells and Head |
221 | HLW-431.5 Some Acceptable Types of Welds for Fittings, Nozzles, and Other Connections to Shells and Head |
223 | HLW-432.1 Some Acceptable Types of Brazed Fittings, Nozzles, and Other Connections to Copper‐Lined Shells and Heads |
230 | HLW-602.1 Official Symbol to Denote The American Society of Mechanical Engineers’ Standard HLW-602.2 Form of Stamping on Completed Water Heaters |
234 | HLW-809.1 Expansion Tank Capacities for a Water Heater |
235 | HLW-809.1 A Typical Acceptable Piping Installation for Storage Water Heaters in Battery |
236 | HLW-809.2 A Typical Acceptable Piping Installation for Flow Through Water Heater With Provisions for Piping Expansion |
237 | 2-100 Codes, Standards, and Specifications Referenced in Text |
242 | 4-1 Guide for the Preparation of Section IV Manufacturer’s Data Report Forms |
245 | H-2 Manufacturer’s Data Report for All Types of Boilers Except Watertube and Those Made of Cast Iron |
247 | H-3 Manufacturer’s Data Report for Watertube Boilers |
249 | H-4 Manufacturer’s Partial Data Report |
251 | H-5 Manufacturer’s Master Data Report for Boilers Constructed from Cast Iron |
253 | H-5A Manufacturer’s Master Data Report for Boilers Constructed from Cast Aluminum |
255 | H-6 Manufacturer’s Data Report Supplementary Sheet |
256 | HC-1 Manufacturer’s Material Certificate of Conformance for Cast Iron Boiler Sections |
257 | HC-2 Manufacturer’s Material Certificate of Conformance for Hydrostatic Testing of Cast Iron Boiler Sections |
258 | HC-3 Manufacturer’s Report for the Application of Nameplates on Cast Iron Boilers |
259 | HA-1 Manufacturer’s Material Certificate of Conformance for Cast Aluminum Boiler Sections |
260 | HA-2 Manufacturer’s Material Certificate of Conformance for Hydrostatic Testing of Cast Aluminum Boiler Sections |
261 | HA-3 Manufacturer’s Report for the Application of Nameplates on Cast Aluminum Boilers |
262 | HLW-6 Manufacturer’s Data Report for Water Heaters or Storage Tanks |
264 | HLW-7 Manufacturer’s Partial Data Report for Water Heaters and Storage Tanks |
266 | HLW-8 Manufacturer’s Master Data Proof Test Report for Water Heaters or Storage Tanks |
269 | 6-1 Standard Units for Use in Equations |
273 | 8-1 Certificate of Conformance for Reapplication of the Certification Mark |
274 | 8-200-1 Guide for Completing the Certificate of Conformance for Reapplication of the Certification Mark |
278 | A-100 Guide for Estimating Steaming Capacity Based on Heating Surface |
283 | D-100 Computation of Typical Pad Reinforcement |
284 | D-101 Computation of a Typical Nozzle Fitting |
295 | K-1 Sample Certificate of Authorization |
300 | N-1 Guide for the Preparation of Section IV Manufacturer’s Certificate of Conformance Form HV-1 |
301 | HV-1 Manufacturer’s Certificate of Conformance for Pressure Relief Valves |