PDF Pages PDF Title
49 Submittal of Technical Inquiries to the Boiler and Pressure Vessel Standards Committees
53 IWA-1600-1 Referenced Standards and Specifications
57 IWA-2211-1 Visual Examinations
60 IWA-2322-1 Near‐Distance Acuity Test Distances and Character Heights
65 IWA-3310-1 Surface Planar Flaws Oriented in Plane Normal to Pressure Retaining Surface
67 IWA-3320-1 Subsurface Planar Flaws Oriented in Plane Normal to Pressure Retaining Surface
68 IWA-3320-2 Successive Examination Surface Proximity Rule for Class 1 and Class 2 Vessels
69 IWA-3330-1 Multiple Planar Flaws Oriented in Plane Normal to Pressure Retaining Surface
70 IWA-3340-1 Nonplanar Elliptical Subsurface Flaws
71 IWA-3350-1 Parallel Planar Flaws
72 IWA-3360-1 Laminar Flaws
73 IWA-3380-1 Nonaligned Coplanar Flaws in Plane Normal to Pressure Retaining Surface
74 IWA-3390-1 Multiple Aligned Planar Flaws (1/2 in. = 13 mm)
75 IWA-3400-1 Linear Surface Flaws
86 IWA-4461.1-1 Minimum Preheat Temperature, °F (°C)
91 IWA-4623.1-1 Temper Bead Welding and Weld Temper Bead Reinforcement
92 IWA-4623.2-1 Automatic or Machine (GTAW) Temper Bead Welding
94 IWA-4633.1-1 Temper Bead Welding and Weld Temper Bead Reinforcement of Dissimilar Metal Welds or Buttering
95 IWA-4633.2-1 Automatic or Machine (GTAW) Temper Bead Welding of Dissimilar Metal Welds or Buttering
97 IWA-4643.2-1 Automatic or Machine (GTAW) Temper Bead Welding of Cladding
100 IWA-4652.4-1 Temper Bead Technique
101 IWA-4652.4-2 Illustration of the Temper Bead Technique for Reinforcement of Existing Fillet Welds
102 IWA-4655-1 Welding Techniques for Improper Temper Bead Spacing
103 IWA-4655-2 Example of Weld Undercut Welding Technique
104 IWA-4662.1-1 Depth Limitations for Underwater Welding Qualification
105 IWA-4663.1-1 Carbon Equivalency Calculation
IWA-4662.1-2 Procedure and Performance Qualification – Position Limitations
110 IWA-4712.2-1 Examples of Extension and Recess of Tube and Plug
116 IWA-5210-1
128 IWB-2411-1 Inspection Program
132 IWB-2500-1 (B-A) Examination Category B-A, Pressure Retaining Welds in Reactor Vessel
133 IWB-2500-1 (B-B) Examination Category B-B, Pressure Retaining Welds in Vessels Other Than Reactor Vessels
135 IWB-2500-1 (B-D) Examination Category B-D, Full Penetration Welded Nozzles in Vessels
136 IWB-2500-1 (B-F) Examination Category B-F, Pressure Retaining Dissimilar Metal Welds in Vessel Nozzles
137 IWB-2500-1 (B-G-1) Examination Category B-G-1, Pressure Retaining Bolting, Greater Than 2 in. (50 mm) in Diameter
140 IWB-2500-1 (B-G-2) Examination Category B-G-2, Pressure Retaining Bolting, 2 in. (50 mm) and Less in Diameter
141 IWB-2500-1 (B-J) Examination Category B-J, Pressure Retaining Welds in Piping
143 IWB-2500-1 (B-K) Examination Category B-K, Welded Attachments for Vessels, Piping, Pumps, and Valves
145 IWB-2500-1 (B-L-2, B-M-2) Examination Categories B-L-2, Pump Casings; B-M-2, Valve Bodies
146 IWB-2500-1 (B-N-1, B-N-2, B-N-3) Examination Categories B-N-1, Interior of Reactor Vessel; B-N-2, Welded Core Support Structures and Interior Attachments to Reactor Vessels; B-N-3, Removable Core Support Structures
147 IWB-2500-1 (B-O) Examination Category B-O, Pressure Retaining Welds in Control Rod Drive and Instrument Nozzle Housings
148 IWB-2500-1 (B-P) Examination Category B-P, All Pressure Retaining Components
149 IWB-2500-1 (B-Q) Examination Category B-Q, Steam Generator Tubing
150 IWB-2500-1 Vessel Shell Circumferential Weld Joints
151 IWB-2500-2 Vessel Shell Longitudinal Weld Joints
152 IWB-2500-3 Spherical Vessel Head Circumferential and Meridional Weld Joints
153 IWB-2500-4 Shell‐to‐Flange Weld Joint
154 IWB-2500-5 Head‐to‐Flange Weld Joint
155 IWB-2500-6 Typical Tubesheet‐to‐Head Weld Joints
156 IWB-2500-7(a) Nozzle in Shell or Head
157 IWB-2500-7(b) Nozzle in Shell or Head
158 IWB-2500-7(c) Nozzle in Shell or Head
159 IWB-2500-7(d) Nozzle in Shell or Head
160 IWB-2500-8 Similar and Dissimilar Metal Welds in Components, Nozzles, and Piping
163 IWB-2500-9 Pipe Branch Connection
164 IWB-2500-10 Pipe Branch Connection
165 IWB-2500-11 Pipe Branch Connection
166 IWB-2500-12 Closure Stud and Threads in Flange Stud Hole
167 IWB-2500-13 Welded Attachment
168 IWB-2500-14 Welded Attachment
169 IWB-2500-15 Welded Attachment
170 IWB-2500-18 Control Rod Drive and Instrument Nozzle Housing Welds
171 IWB-2500-20 Extent of Weld Examination
175 IWB-3410-1 Acceptance Standards
176 IWB-3510-1 Allowable Planar Flaws
IWB-3510-2 Allowable Laminar Flaws
177 IWB-3510-3 Allowable Linear Flaws
IWB-3512-1 Allowable Planar Flaws
178 IWB-3512-2 Component Thickness Vs Flaw Location
179 IWB-3514-1 Allowable Planar Flaws
180 IWB-3514-2 Allowable Linear Flaws
IWB-3514-3 Allowable Laminar Flaws
181 IWB-3514-4 Allowable Linear Flaws
182 IWB-3515-1 Allowable Planar Flaws
184 IWB-3519.2-1 Allowable Planar Flaws
185 IWB-3519.2-2 Allowable Planar Flaws
187 IWB-3610-1 Characterization and Proximity Rules for Analytical Evaluation of Clad Components
189 IWB-3662-1 Definition of Circumferential Orientation for Flaw Characterization
190 IWB-3663-1 Reactor Vessel Head Penetration Nozzle Acceptance Criteria
191 IWB-5230-1 Test Pressure
194 IWC-2411-1 Inspection Program
197 IWC-2500-1 (C-A) Examination Category C-A, Pressure Retaining Welds in Pressure Vessels
198 IWC-2500-1 (C-B) Examination Category C-B, Pressure Retaining Nozzle Welds in Pressure Vessels
199 IWC-2500-1 (C-C) Examination Category C-C, Welded Attachments for Pressure Vessels , Piping, Pumps, and Valves
200 IWC-2500-1 (C-D) Examination Category C-D, Pressure Retaining Bolting Greater Than 2 in. (50 mm) in Diameter
201 IWC-2500-1 (C-F-1) Examination Category C-F-1, Pressure Retaining Welds in Austenitic Stainless Steel or High Alloy Piping
202 IWC-2500-1 (C-F-2) Examination Category C-F-2, Pressure Retaining Welds in Carbon or Low Alloy Steel Piping
204 IWC-2500-1 (C-H) Examination Category C-H, All Pressure Retaining Components
205 IWC-2500-1 Vessel Circumferential Welds
206 IWC-2500-2 Typical Tubesheet‐to‐Shell Circumferential Welds
207 IWC-2500-3 Nozzle‐to‐Vessel Welds
208 IWC-2500-4 Nozzle‐to‐Vessel Welds
211 IWC-2500-5 Welded Attachments
212 IWC-2500-6 Pressure Retaining Bolting
213 IWC-2500-7 Welds in Piping
215 IWC-2500-9 Branch Connection Welds
216 IWC-2500-10 Pipe Branch Connection
217 IWC-2500-11 Pipe Branch Connection
218 IWC-2500-12 Pipe Branch Connection
219 IWC-2500-13 Pipe Branch Connection
222 IWC-3410-1 Acceptance Standards
223 IWC-3510-1 Allowable Planar Flaws
IWC-3510-2 Allowable Laminar Flaws
224 IWC-3510-3 Allowable Linear Flaws
IWC-3511-1 Allowable Planar Flaws
225 IWC-3511-2 Allowable Linear Flaws
IWC-3513-1 Allowable Planar Flaws
227 IWC-3514-1 Allowable Planar Flaws
233 IWD-2411-1 Inspection Program
236 IWD-2500-1 (D-A) Examination Category D-A, Welded Attachments for Pressure Vessels , Piping, Pumps, and Valves
237 IWD-2500-1 (D-B) Examination Category D-B, All Pressure Retaining Components
238 IWD-2500-1 Welded Attachments
240 IWD-3410-1 Acceptance Standards
247 IWE-2411-1 Inspection Program
249 IWE-2500-1 (E-A) Examination Category E-A, Containment Surfaces
250 IWE-2500-1 (E-C) Examination Category E-C, Containment Surfaces Requiring Augmented Examination
251 IWE-2500-1 (E-G) Examination Category E-G, Pressure Retaining Bolting
252 IWE-2500-1 Examination Areas for Moisture Barriers
258 IWF-1300-1 Illustrations of Typical Support Examination Boundaries
260 IWF-2410-1 Inspection Program
262 IWF-2500-1 (F-A) Examination Category F-A, Supports
270 IWL-2500-1 (L-A) Examination Category L‐A, Concrete
271 IWL-2500-1 (L-B) Examination Category L‐B, Unbound Post-Tensioning System
273 IWL-2521-1 Number of Tendons for Examination
274 IWL-2521-2 Augmented Examination Requirements Following Post‐Tensioning System Repair/Replacement Activities
276 IWL-2525-1 Corrosion Protection Medium Analysis
293 NIS-1 Owner’s Report for Inservice Inspections
296 NIS-2 Owner’s Report for Repair/Replacement Activity
571 RRA-1 Report of Contracted Repair/Replacement Activity
602 FOREWORD
INTRODUCTION
609 INTERPRETATIONS Volume 62