Shopping Cart

No products in the cart.

ASME CSD 1 09:2009 Edition

$98.04

ASME CSD 1 Control and Safety Devices for Automatically Fired Boilers

Published By Publication Date Number of Pages
ASME 2009 66
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

None

PDF Catalog

PDF Pages PDF Title
6 FOREWORD
7 COMMITTEE ROSTER
8 CORRESPONDENCE WITH THE CSDAFB COMMITTEE
9 SUMMARY OF CHANGES
12 Part CG General
CG-100 GENERAL REQUIREMENTS
CG-110 Scope
CG-120 Service Limitations
CG-130 Exclusions
CG-140 Acceptance by Other Listings
CG-150 Jurisdictional Adoption of CSD-1
CG-160 Metric SI Units
13 CG-200 GENERAL PROVISIONS
CG-210 General Provisions
CG-220 Installation
CG-230 Observation Ports
CG-240 Guarding
CG-250 Annunciator Systems
CG-260 Combustion Air
CG-300 MATERIAL REQUIREMENTS
CG-310 Components
CG-400 TESTING AND MAINTENANCE
CG-410 Cleaning
CG-420 Testing
CG-430 Maintenance
CG-440 Operational Testing
14 CG-500 CERTIFICATION AND REPORTING
CG-510 Certification and Reporting
CG-600 OPERATION
CG-610 Lockout
CG-700 DEFINITIONS
18 Fig. 1 Sediment Trap
19 Part CM Testing and Maintenance
CM-100 PERIODIC TESTING AND MAINTENANCE
CM-110 General
CM-120 Familiarity With Equipment and Procedures
CM-130 Periodic Maintenance and Testing
20 Part CE Electrical
CE-100 ELECTRICAL REQUIREMENTS
CE-110 General
CE-120 Overcurrent Protection
CE-130 Motors
21 CE-140 Ignition System
CE-150 Wiring
CE-160 Bonding and Grounding
22 Part CW Steam and Waterside Control
CW-100 AUTOMATIC LOW-WATER FUEL CUTOFF AND/OR COMBINED WATER FEEDING DEVICE
CW-110 General Requirements for Water Level Controls for All Boilers
CW-120 Requirements for Water Level Controls for Low-Pressure Steam or Vapor System Boilers
23 CW-130 Requirements for Water Level Controls for Hot-Water Heating Boilers
CW-140 Requirements for Water Level Controls for High-Pressure Steam Boilers
24 CW-150 Requirements for Operating and Safety Controls for Electrically Heated Boilers
CW-200 AUTOMATIC FUEL CUTOFF FOR FORCED CIRCULATION BOILERS
CW-210 Requirements for Flow or Temperature-Sensing Devices for Forced Circulation Boilers
CW-300 PRESSURE CONTROLS
CW-310 Requirements for Pressure Controls for Steam Boilers
25 CW-400 TEMPERATURE CONTROLS
CW-410 Requirements for Temperature Controls for Hot-Water Heating and Supply Boilers
CW-500 SAFETY AND SAFETY RELIEF VALVES
CW-510 Requirements for Steam and Hot-Water Heating Boilers
CW-520 Requirements of Hot-Water Supply Boilers
CW-600 MODULAR BOILERS
CW-610 Water Level Controls for Modular Steam Heating Boilers
CW-620 Pressure Controls for Modular Steam Heating Boilers
26 CW-630 Water Level Controls for Modular Hot-Water Boilers
CW-640 Temperature Controls for Modular Hot-Water Heating Boilers
27 Part CF Combustion Side Control
CF-100 GAS-FIRED BOILER UNITS, EQUIPMENT
CF-110 Burner Assemblies and Boiler Units
CF-120 Fuel Train
CF-130 Filters or Strainers
CF-140 Sediment Traps and Drips
CF-150 Manually Operated Gas Shutoff Valves
28 Table CF-1 400,000 Btu/hr (117 228 W) and Smaller (Gas — Natural Draft)
29 Table CF-2 400,000 Btu/hr (117 228 W) and Smaller (Power Gas Burners and MechanicalDraft Atmospheric Gas Burners), 3 gph (11.4 L/h) and Smaller (Oil)
30 CF-160 Gas-Pressure Regulators
CF-161 Overpressure Protection
CF-162 Pressure Switches
31 Table CF-3 Safety Controls for Automatically Fired Units: Power Gas Burners and Mechanical Draft Atmospheric Gas Burners
32 Table CF-4 Safety Controls for Automatically Fired Units: Atmospheric Gas Burners — Natural Draft
33 CF-170 Control Valves
CF-180 Safety Shutoff Valves
CF-190 Atmospheric Vents and Gas Vent, Bleed, or Relief Lines
34 CF-200 GAS-FIRED BOILER UNITS, PURGING
CF-210 Preignition Purging See Table CF-3 or CF-4
CF-220 Control
CF-300 GAS-FIRED BOILER UNITS, SAFETY CONTROLS
CF-310 Primary Safety Control
35 CF-320 Automatic Ignition Devices
CF-330 Action on Flame Failure Refer to Tables CF-1 Through CF-4
CF-400 OIL-FIRED BOILER UNITS, EQUIPMENT
CF-410 Burner Assemblies
36 CF-420 Fuel Train
CF-430 Filters or Strainers
CF-440 Relief Valves
CF-450 Pressure and Temperature Switches
CF-460 Safety Shutoff Valves
CF-470 Oil-Fired Boiler Units, Purging See Table CF-5
CF-480 Combustion Air Proving Refer to Table CF-5
37 Table CF-5 Safety Controls for Automatically Fired Units: Oil-Fired Burners
38 CF-500 OIL-FIRED BOILER UNITS, SAFETY CONTROLS
CF-510 Primary Safety Control
CF-520 Automatic Ignition Devices
CF-530 Action on Flame Failure Refer to Tables CF-2 and CF-5
CF-600 LOW FIRE START, GAS- OR OIL-FIRED BOILER UNITS
CF-610 Low Fire Start
CF-700 COMBINATION GAS- AND OIL-FIRED UNITS
CF-710 Burner Assemblies
CF-800 ELECTRICALLY HEATED BOILERS
CF-810 General
CF-900 COMBUSTION SIDE CONTROLS FOR MODULAR BOILERS
CF-910 Gas Modular Boilers
39 CF-920 Oil Modular Boilers
CF-930 Electric Modular Boilers
40 NONMANDATORY APPENDIX A COMPARISON OF THIS STANDARD AND ANSI Z21.13/CSA 4.9
41 NONMANDATORY APPENDIX B TYPICAL FUEL TRAINS
47 NONMANDATORY APPENDIX C MANUFACTURERŒS/INSTALLING CONTRACTORŒS REPORT FOR ASME CSD-1
50 NONMANDATORY APPENDIX D RECOMMENDED PREVENTIVE MAINTENANCE SCHEDULE
D-1 DAILY
D-2 WEEKLY
D-3 MONTHLY
D-4 SEMI-ANNUALLY
D-5 ANNUALLY
D-6 AS REQUIRED
54 NONMANDATORY APPENDIX E REFERENCES
55 NONMANDATORY APPENDIX F GUIDANCE FOR THE USE OF U.S. CUSTOMARY AND SI UNITS IN CSD-1
F-1 USE OF UNITS IN EQUATIONS
F-2 GUIDELINES USED TO DEVELOP SI EQUIVALENTS
57 F-3 SOFT CONVERSION FACTORS
58 INDEX
ASME CSD 1 09