1.1 This specification establishes the requirements for electrolytic copper cathode; electrorefined and electrowon.

1.2 UnitsThe values stated in inch-pound units are the standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Note 1

Cathode produced to this specification corresponds to the designation ‘Cath’ as defined in Classification B 224 and may be used to produce all other coppers listed in Classification B 224 that are normally produced from ‘Cath’ copper.

Note 2

Grade 1 cathode conforms to the chemical compositional requirements of Copper UNS No. C11040, except for oxygen, and is suitable for the manufacture of wire rod as designated in Specification B 49.

The following hazard caveat applies to the test methods described in of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
Ordering Information
Chemical Composition
Physical Property Requirements
2 Dimensions, Mass, and Permissible Variations
Workmanship, Finish, and Appearance
Sampling
Number of Tests and Retests
Specimen Preparation
Test Methods
Significance of Numerical Limits
Inspection
Rejection and Rehearing
TABLE 1
3 Packaging and Package Marking
Keywords
A1. SAMPLING AND SPECIMEN PREPARATION OF ELECTROLYTIC CATHODE COPPER FOR DETERMINATION OF COMPLIANCE WITH SPECIFICATION REQUIREMENTS
A1.1 Scope
A1.2 Terminology
A1.3 Selection of Cathode
A1.4 Sample Preparation
4 FIG. A1.1
5 FIG. A1.2
6 A1.5 Specimen Preparation
A2. TEST METHODS FOR DETERMINATION OF COMPLIANCE WITH CHEMICAL COMPOSITION REQUIREMENTS FOR ELECTROLYTIC COPPER CATHODE
A2.1 Scope
A2.2 Significance and Use
A2.3 Apparatus
A2.4 Reagents and Material
A2.5 Sampling
A2.6 Rounding Calculated Values
A2.7 Scope
A2.8 Summary of Test Method A
A2.9 Significance and Use
7 A2.10 Interferences
A2.11 Hazards
A2.12 Apparatus
A2.13 Reagents and Materials
TABLE A2.1
8 A2.14 Calibration
A2.15 Procedure
A2.16 Calculations
A2.17 Precision and Bias
A2.18 Scope
A2.19 Summary of Test Method B
A2.20 Interferences
TABLE A2.2
9 A2.21 Apparatus
A2.22 Reagents and Material
A2.23 Hazards
A2.24 Preparation of Apparatus
A2.25 Sample Preparation
A2.26 Calibration
A2.27 Procedure
A2.28 Calculations
A2.29 Precision and Bias
ASTM-B115