Shopping Cart

No products in the cart.

ASTM-B280 2008(Redline)

$26.65

B280-08 Standard Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service (Redline)

Published By Publication Date Number of Pages
ASTM 2008 12
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

Abstract

This specification covers the requirements for seamless UNS C10200, C12000, or C12200 copper alloy tubes used for connection, repairs, or alternations of field air conditioning or refrigeration units. Materials in the form of billets, bars, or tubes should be used to produce a homogeneous uniform wrought structure by either hot or cold working. Each tube should be cold drawn to the finished size and wall thickness. Coiled lengths with soft annealed tempers should be bright annealed after coiling then dehydrated and either capped, plugged, crimped, or otherwise closed at both ends. Straight lengths with hard drawn tempers should be cleaned and either capped, plugged, or otherwise closed at both ends. The grain sizes, tensile properties, and eddy-current and cleanness test results should conform to the values listed herein.

This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

1. Scope

1.1 This specification establishes the requirements for seamless copper tube intended for use in the connection, repairs, or alternations of air conditioning or refrigeration units in the field.

Note 1ā€”Fittings used for soldered or brazed connections in air conditioning and refrigeration systems are described in ASME Standard B16.22.

Note 2ā€”The assembly of copper tubular systems by soldering is described in Practice B 828.

Note 3ā€”Solders for joining copper tubular systems are described in Specification B 32. The requirements for acceptable fluxes for these systems are described in Specification B 813.

1.2 The tube shall be produced from the following coppers, and the manufacturer has the option to supply any one of them, unless otherwise specified:

1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.4 The following hazard statement pertains only to the test method described in Section 18.2.4 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM Standards

B32 Specification for Solder Metal B153 Test Method for Expansion (Pin Test) of Copper and Copper-Alloy Pipe and Tubing B577 Test Methods for Detection of Cuprous Oxide (Hydrogen Embrittlement Susceptibility) in Copper B601 Classification for Temper Designations for Copper and Copper Alloys–Wrought and Cast B813 Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube B828 Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings B900 Practice for Packaging of Copper and Copper Alloy Mill Products for U.S. Government Agencies E3 Guide for Preparation of Metallographic Specimens

ASTM-B280 2008