ASTM-C1280:2012 Edition(Redline)
$23.40
C1280-12a Standard Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing (Redline)
Published By | Publication Date | Number of Pages |
ASTM | 2012 | 5 |
This specification covers the minimum requirements for and the methods of application of gypsum sheathing for use as a substrate for exterior wall cladding. Gypsum sheathing board is a substrate that shall be covered by an exterior cladding or other weather-resistive barrier and is not intended for long-term exposure. Framing members shall be installed so that the surface will be in an even plane, unless otherwise specified, after the gypsum sheathing has been applied. The gypsum sheathing shall be cut by scoring and breaking or by sawing, working from the face side. The cut edges and ends of gypsum sheathing shall be trimmed to obtain neat fitting joints when installed. Gypsum sheathing shall be fitted snugly around all window and door openings. Control joints, other accessories, and metal plaster base shall be fastened through gypsum sheathing to framing members. Where fire resistance or shear resistance is not required, and when metal lath and Portland cement plaster are to be applied as the exterior cladding over gypsum sheathing installed over framing members and the metal lath shall be installed after the gypsum sheathing, the gypsum sheathing shall be permitted to be applied and fastening of the gypsum sheathing shall be completed with the attachment of the self-furred metal lath.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This specification covers the minimum requirements for and methods of application of exterior gypsum panel products that are specifically designed for use as a substrate for exterior cladding.
1.1.1 This specification does not cover gypsum panel products that are specifically designed for interior applications.
1.2 Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing laboratories.
1.2.1 This specification shall govern where it is more stringent (size or thickness of framing and size and spacing of fasteners) than the fire-rated construction.
1.3 Where sound control is required for a gypsum panel product assembly, the details of construction shall be in accordance with the acoustical test report of an assembly that has met the required acoustical value(s).
1.3.1 This specification shall govern where it is more stringent (size or thickness of framing and size and spacing of fasteners) than the sound-rated construction.
1.4 Where resistance to racking loads or shear is required for a gypsum panel product assembly, the details of construction shall be in accordance with the racking or shear test report of an assembly that has met the required racking or shear value(s).
1.4.1 This specification shall govern where it is more stringent (size or thickness of framing and size and spacing of fasteners) than the racking or shear-tested construction.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6 The text of this standard references notes which provide explanatory material. These notes shall not be considered as requirements of the standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C11 Terminology Relating to Gypsum and Related Building Materials and Systems C954 Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 in. (0.84 mm) to 0.112 in. (2.84 mm) in Thickness C955 Specification for Load-Bearing (Transverse and Axial) Steel Studs, Runners (Tracks), and Bracing or Bridging for Screw Application of Gypsum Panel Products and Metal Plaster Bases C1002 Specification for Steel Self-Piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs C1007 Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories C1063 Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster C1177/C1177M Specification for Glass Mat Gypsum Substrate for Use as Sheathing C1278/C1278M Specification for Fiber-Reinforced Gypsum Panel C1396/C1396M Specification for Gypsum Board
U.S. Department of Commerce Publication
PS20 American Softwood Lumber Standard Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700 Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
Keywords
exterior walls; gypsum; gypsum panel products; sheathing;
ICS Code
ICS Number Code 91.060.10 (Walls. Partitions. Facades); 91.100.10 (Cement. Gypsum. Lime. Mortar)
DOI: 10.1520/C1280-12A ASTM International is a member of C