ASTM-D6383 2005
$35.75
D6383-99(2005) Standard Practice for Time-to-Failure (Creep-Rupture) of Adhesive Joints Fabricated from EPDM Roof Membrane Material
Published By | Publication Date | Number of Pages |
ASTM | 2005 | 3 |
ASTM D6383-99-Reapproved2005
Historical Standard: Standard Practice for Time-to-Failure (Creep-Rupture) of Adhesive Joints Fabricated from EPDM Roof Membrane Material
ASTM D6383
Scope
1.1 This practice covers sample preparation temperatures, test parameters, and specimen exposure conditions that are applicable when Test Method D 5405 is used for conducting time-to-failure (creep-rupture) tests of adhesive joints fabricated from ethylene-propylene-diene terpolymer (EPDM) roof membrane material.
1.2 This practice is applicable to joints fabricated in the laboratory from EPDM roof membrane materials and adhesives received from suppliers, and to joints prepared from EPDM seams sampled from field installations.
1.3 The joints are bonded using preformed tape or liquid-based adhesives, and EPDM roof membrane materials that are non-reinforced, fabric- or scrim-reinforced, and fabric backed. Primers are also used as recommended for the specific adhesive.
1.4 This practice contains notes that are explanatory and are not part of the mandatory requirements of this practice.
1.5 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of the regulatory limitations prior to use.
Keywords
adhesive testings; creep; EPDM; joints; laboratory exposure; practice; roofing; seams; test conditions; time-to-failure
ICS Code
ICS Number Code 91.060.20 (Roofs)
DOI: 10.1520/D6383-99R05
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology Summary of Practice Significance and Use |
2 | Test Specimen Number of Test Specimens and Bonded Strength TABLE 1 |
3 | Loads Artificial Exposure Before Conducting Time-to-Failure Tests Procedure Report Keywords |