ASTM-E1571:2011 Edition
$40.63
E1571-11 Standard Practice for Electromagnetic Examination of Ferromagnetic Steel Wire Rope
Published By | Publication Date | Number of Pages |
ASTM | 2011 | 6 |
1.1 This practice covers the application and standardization of instruments that use the electromagnetic, the magnetic flux, and the magnetic flux leakage examination method to detect flaws and changes in metallic cross-sectional areas in ferromagnetic wire rope products.
1.1.1 This practice includes rope diameters up to 2.5 in. (63.5 mm). Larger diameters may be included, subject to agreement by the users of this practice.
1.2 Units The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology Summary of Practice |
2 | FIG. 1 FIG. 2 FIG. 3 |
3 | Significance and Use Basis of Application Limitations FIG. 4 FIG. 5 |
4 | Apparatus Examination Procedure Reference Standard |
5 | Test Agency Qualification Keywords |