BS 5911-1:2002+A2:2010

$142.49

Concrete pipes and ancillary concrete products – Specification for unreinforced and reinforced concrete pipes (including jacking pipes) and fittings with flexible joints (complementary to BS EN 1916:2002)

Published By Publication Date Number of Pages
BSI 2010 26
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

BS EN 1916 specifies requirements and describes test methods for precast concrete pipes and fittings, unreinforced, steel fibre and reinforced, with flexible joints and nominal sizes not exceeding DN 1750 or WN/HN 1200/1800, for which the main intended use is the conveyance of sewage, rainwater and surface water under gravity or occasionally at low head of pressure in pipelines that are generally buried. The scope includes pipes (collectively referred to as “jacking pipes”) intended to be installed by pipe jacking, microtunnelling or other trenchless technology.

This part of BS 5911 specifies complementary requirements to those in BS EN 1916 for unreinforced and reinforced concrete pipes and fittings, as provided for in that European Standard, with nominal sizes not exceeding DN 1500 for circular pipes with base and WN/HN 800/1200 for egg-shaped pipes. Full requirements for reinforced concrete circular trench and jacking pipes with nominal sizes greater than DN 1750, but not exceeding DN 3000, are also specified.

In addition to pipes and fittings having a circular cross-section, BS EN 1916 also covers circular pipes with base and egg-shaped pipes, neither of which are within the scope of BS 5911‑100. However, these products are now manufactured in the United Kingdom and so they have been included in this part of BS 5911.

Steel fibre concrete jacking pipes are not manufactured in the United Kingdom and so are excluded from this part of BS 5911. BS EN 752 , BS EN 1295‑1 and BS EN 1610 deal with the planning, design, installation and testing of drains and sewers. The Pipe Jacking Association’s “Guide to best practice for the installation of pipe jacks and microtunnels” [3] is a source of advice on the use of jacking pipes.

Contains requirements from BS 5911-100 and BS 5911-120 that could not be agreed upon for inclusion in BS EN 1916.

PDF Catalog

PDF Pages PDF Title
1 BRITISH STANDARD
2 Committees responsible for this British�Standard
3 Contents
5 1 Scope
2 Normative references
6 3 Terms and definitions
cementitious content
circular unit
circular pipe with base
egg-shaped
Typical geometric form for an egg-shaped bore
7 lifting anchorage
manufacturing diameter
4 Symbols
Symbols
5 General requirements
5.1 Application
5.2 Concrete
8 Cementitious content
9 Cement or combination groups�
10 5.3 Finish
5.4 Geometrical characteristics
11 Nominal sizes and tolerances of units with a circular bore, for use in a trench
Nominal sizes and tolerances of egg-shaped units
12 Nominal sizes, internal manufacturing diameter and tolerances of jacking pipes
13 Tolerances on the squareness of ends of jacking pipes
5.5 Durability of joints
5.6 Crushing strength
14 Minimum crushing loads for strength class 120 units with a circular bore for use in a trench
15 Minimum crushing loads for strength class 150 egg�shaped units
Minimum crushing loads for strength class 120 jacking pipes
5.7 Lifting anchorages
5.8 Bends
16 6 Special requirements
6.1 Reinforced concrete units
7 Conformity evaluation
7.1 Application
7.2 Finish
7.3 Geometrical characteristics
7.4 Lifting anchorages
8 Marking
17 Annex A (informative) Information to be supplied in an enquiry or order
Annex B (normative) British Standards relevant to BS EN 1916:2002
British Standards relevant to BS EN 1916:2002
18 Annex C (normative) Surface finish tests
Surface evenness test
Principle
Apparatus
Gauge for assessing surface evenness
Procedure
Expression of result
Surface void test
Principle
Apparatus
19 Gauge for assessing surface voids
Procedure
Expression of result
Annex D (normative) Dimensional tests
Internal dimensions test
Principle
Apparatus
Procedure
Expression of results
External diameter test for jacking pipes
Principle
Apparatus
20 Procedure
Expression of results
Wall thickness test
Principle
Apparatus
Procedure
Expression of results
Straightness test
Principle
Apparatus
Gauge for measuring deviation from straightness
21 Procedure
Expression of result
Internal barrel length and squareness of ends tests for jacking pipes
Internal barrel length and squareness across a diameter test
Measurement of internal lengths and diagonals of a jacking pipe
22 Squareness of ends across a diameter of a jacking pipe
Squareness across the wall thickness test
23 Annex E (normative) Lifting anchorage pull-out test
Principle
Apparatus
Testing machine
Diagram of typical anchorage pull-out testing machine on longitudinal section of unit wall
Preparation
Procedure
Place the apparatus on the unit and connect it to the lifting anchorage.
Apply the load at a uniform rate of between 150�kN/min and 250�kN/min, or in increments of not mo…
Expression of result
BS 5911-1:2002+A2:2010