BS 7856:2017 – TC:2020 Edition

$217.84

Tracked Changes. Specification for special design and other features of alternating current watthour meters for active energy for use in the UK (Accuracy Classes A and B)

Published By Publication Date Number of Pages
BSI 2020 78
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
48 Foreword
51 1 Scope
2 Normative references
3 Terms and definitions
52 4 Mechanical features
53 Table 1 — Dimensions and spacing of fixing holes and terminals
54 Figure 1 — Spacing of fixing holes and terminals for single-phase, two-wire meter
55 5 Electrical features
Table 2 — Standard currents for meters of Class A or Class B
57 Figure 2 — Diagrams of connections for a single-phase, two-wire, one-rate meter
58 Figure 3 — Diagrams of connections and graphical symbols for a two-element meter used on three-wire systems
59 Figure 4 — Diagrams of connections and graphical symbols for a two-element meter used on a two-phase, four-wire system
60 Figure 5 — Diagrams of connections and graphical symbols for a three-element meter used on a three-phase, four-wire system
61 6 Other features
62 Annex A (normative)  Test method of a terminal’s ability to safely clamp standard UK cables
63 Figure A.1 — Test arrangement for clamping ability of a meter terminal
64 Annex B (normative)  External rate switching logic for multi-rate meters
Table B.1 — Sequence for multi-rate registers having two to eight rates
65 Annex C (normative)  Long-term overcurrent test requirements
66 Annex D (normative)  Performance criteria for load switches inside meters
Table D.1 — Performance criteria for supply control and load control switches
67 Figure D.1 — Polyphase meter supply control switch test timing
68 Figure D.2 — Contact resistance derived from mV drop measured at meter terminals at Imax
69 Annex E (normative)  Sealing criteria
70 Annex F (informative)  Operational considerations related to switches inside meters
71 Figure F.1 — Typical heating in a 100 AImax meter when subjected to 1.45 * Imax
72 Table F.1 — Thermal stresses on a 100 A SCS protected by various OCPD ratings
73 Table F.2 — Characteristics of OCPDs in common domestic use in the UK
74 Figure F.2 — Current levels for determining OCPD characteristics
76 Bibliography
BS 7856:2017 - TC
$217.84