BS EN 12616:2022 – TC:2023 Edition
$134.27
Tracked Changes. Surfaces for sports areas. Test methods for the determination of vertical water infiltration and horizontal water flow rates
Published By | Publication Date | Number of Pages |
BSI | 2023 | 52 |
This document has two parts. Part 1 specifies four methods for the determination of the vertical water infiltration rate of different types of sports surfacing. Method A is suitable for measuring the vertical water infiltration rate of synthetic, textile and synthetic turf sports surfaces in the laboratory. Method B is suitable for on-site measurements of the Vertical Water Infiltration Rate of synthetic, textile, synthetic turf and bound mineral sports surfaces. Method C is suitable for on-site measurements of the vertical water infiltration rate of natural turf sports surfaces. Method D is suitable for measuring the for on-site measurements of the vertical water infiltration rate of unbound mineral sports surfaces. NOTE For filled synthetic turf and unbound mineral surfaces, laboratory tests are considered to give a more precise indication of how a surface will perform. Part 2 specifies a method for determining the horizontal water flow rate of synthetic, textile and synthetic turf surfaces in the laboratory.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 30471189 |
31 | A-30441585 |
32 | undefined |
36 | 1 Scope 2 Normative references 3 Terms and definitions 4 Part 1 – Determination of vertical water infiltration rate 4.1 Method A – laboratory determination of synthetic turf, textile and synthetic sports surfaces 4.1.1 Principle 4.1.2 Apparatus |
37 | 4.1.3 Test specimen |
38 | 4.1.4 Conditioning 4.1.5 Procedure 4.1.6 Calculation and expression of results 4.1.7 Test report |
39 | 4.2 Method B – on-site determination on synthetic textile, synthetic turf, and bound mineral sports surfaces 4.2.1 Principle 4.2.2 Apparatus |
40 | 4.2.3 Test conditions |
41 | 4.2.4 Number and distribution of test locations on site 4.2.5 Procedure 4.2.6 Calculation and expression of results |
42 | 4.2.7 Test report 4.3 Method C – on-site determination on Natural turf 4.3.1 Apparatus 4.3.2 Number and distribution of test locations 4.3.3 Procedure |
43 | 4.3.4 Calculation and expression of results 4.3.5 Test report 4.4 Method D – on-site determination unbound mineral surfaces 4.4.1 Apparatus 4.4.2 Number and distribution of test locations |
44 | 4.4.3 Procedure 4.4.4 Calculation and expression of results 4.4.5 Test report |
45 | 5 Part 2 – Determination in the laboratory of horizontal water flow rate 5.1 Principle 5.2 Apparatus |
47 | 5.3 Test specimens 5.4 Conditioning 5.5 Procedure 5.5.1 Method |
48 | 5.5.2 Acquisition of values 5.5.3 Test directions 5.5.3.1 Samples with single water flow direction 5.5.3.2 Sample with water direction in both senses (at 90°) 5.6 Calculation and expression of results |
49 | 5.7 Test report |
50 | Annex A (Informative)Sample preparation for the determination in the laboratory of horizontal water flow rate |