Shopping Cart

No products in the cart.

BS EN 60130-9:2011

$198.66

Connectors for frequencies below 3 MHz – Circular connectors for radio and associated sound equipment

Published By Publication Date Number of Pages
BSI 2011 58
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weโ€™re here to assist you 24/7.
Email:[email protected]

IEC 60139-9:2011 relates to circular connectors for radio and associated sound equipment. This fourth edition cancels and replaces the third edition of IEC 60130-9, published in 2000, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – the scope has been amended to clarify its separation through its field of application, from IEC 61076-2-106; – 8-pole connector styles 60130-9 IEC-22 through 60130-9 IEC-25 with screw locking have been deleted as obsolete and overlapping with some styles of IEC 61076-2-106; – application and connections in Table 1 have been deleted because of referencing obsolete sound equipment. Titles of the dimension sheets and the clause headlines of Annex A have been amended accordingly; – the reference to safety requirements according to IEC 60065 has been deleted.

PDF Catalog

PDF Pages PDF Title
7 English

CONTENTS
10 1 Scope
2 Normative references
11 3 Technical information
3.1 IEC type designation
12 Tables

Table 1 โ€“ Type designation
13 3.2 Contact arrangements and connections
4 Dimensional information
15 Figures

Figure 1 โ€“ Free connector 60130-9 IEC-01
Table 2 โ€“ Free connector 60130-9 IEC-01
16 Figure 2 โ€“ Fixed connector 60130-9 IEC-02
Table 3 โ€“ Fixed connector 60130-9 IEC-02
17 Figure 3 โ€“ Free connector 60130-9 IEC-03
Table 4 โ€“ Free connector 60130-9 IEC-03
18 Figure 4 โ€“ Fixed connector 60130-9 IEC-04
Table 5 โ€“ Fixed connector 60130-9 IEC-04
19 Figure 5 โ€“ Free connector 60130-9 IEC-05
Table 6 โ€“ Free connector 60130-9 IEC-05
20 Figure 6 โ€“ Fixed connector 60130-9 IEC-06
Table 7 โ€“ Fixed connector 60130-9 IEC-06
21 Figure 7 โ€“ Fixed connector 60130-9 IEC-07
Table 8 โ€“ Fixed connector 60130-9 IEC-07
22 Figure 8 โ€“ Fixed connector 60130-9 IEC-08
Table 9 โ€“ Fixed connector 60130-9 IEC-08
23 Figure 9 โ€“ Free connector 60130-9 IEC-09
Table 10 โ€“ Free connector 60130-9 IEC-09
24 Figure 10 โ€“ Free connector 60130-9 IEC-10
Table 11โ€“ Free connector 60130-9 IEC-10
25 Figure 11 โ€“ Fixed connector 60130-9 IEC-11
Table 12 โ€“ Fixed connector 60130-9 IEC-11
26 Figure 12 โ€“ Free connector 60130-9 IEC-12
Table 13 โ€“ Free connector 60130-9 IEC-12
27 Figure 13 โ€“ Fixed connector 60130-9 IEC-13
Table 14 โ€“ Fixed connector 60130-9 IEC-13
28 Figure 14 โ€“ Free connector 60130-9 IEC-14
Table 15 โ€“ Free connector 60130-9 IEC-14
29 Figure 15 โ€“ Fixed connector 60130-9 IEC-15
Table 16 โ€“ Fixed connector 60130-9 IEC-15
30 Figure 16 โ€“ Fixed connector 60130-9 IEC-15a
Table 17 โ€“ Fixed connector 60130-9 IEC-15a
31 Figure 17โ€“ Free connector 60130-9 IEC-16
Table 18โ€“ Free connector 60130-9 IEC-16
32 Figure 18 โ€“ Fixed connector 60130-9 IEC-17
Table 19 โ€“ Fixed connector 60130-9 IEC-17
33 Figure 19 โ€“ Free connector 60130-9 IEC-18
Table 20 โ€“ Free connector 60130-9 IEC-18
34 Figure 20 โ€“ Fixed connector 60130-9 IEC-19
Table 21 โ€“ Fixed connector 60130-9 IEC-19
35 Figure 21 โ€“ Free connector 60130-9 IEC-20
Table 22 โ€“ Free connector 60130-9 IEC-20
36 Figure 22 โ€“ Fixed connector 60130-9 IEC-21
Table 23 โ€“ Fixed connector 60130-9 IEC-21
37 Figure 23 โ€“ Fixed connector 60130-9 IEC-26
Table 24 โ€“ Fixed connector 60130-9 IEC-26
38 Figure 24 โ€“ Free connector 60130-9 IEC-27
Table 25 โ€“ Free connector 60130-9 IEC-27
39 Figure 25 โ€“ Free connector 60130-9 IEC-28
Table 26 โ€“ Free connector 60130-9 IEC-28
40 Figure 26 โ€“ Fixed connector 60130-9 IEC-29
Table 27 โ€“ Fixed connector 60130-9 IEC-29
41 Figure 27 โ€“ Fixed connector 60130-9 IEC-30
Table 28 โ€“ Fixed connector 60130-9 IEC-30
42 Figure 28 โ€“ Free connector 60130-9 IEC-31
Table 29 โ€“ Free connector 60130-9 IEC-31
43 5 Gauges
5.1 Gauges for checking dimensions
Figure 29 โ€“ Gauge for connector types 60130-9 IEC-02, 04, 07, 08, 09, 11, 13, 15, 17, 18, 21
Figure 30 โ€“ Gauge for connector types60130-9 IEC-07, 08 and 09
Table 30 โ€“ Dimensions of gauges for checking dimensions
44 5.2 Gauges for measuring contact resistance
5.3 Gauges for measuring retention force
Figure 31 โ€“ Gauge for connectortypes 60130-9 IEC-02, 04, 07, 08, 09, 11, 13, 15, 17, 18, 21
Figure 32 โ€“ Gauge for connector types 60130-9 IEC-07, 08 and 09
Table 31 โ€“ Dimensions of gauges for measuring retention force
45 5.4 Gauge for voltage proof and insulation resistance testsof connectors 60130-9 IEC-08
Figure 33 โ€“ Gauge for voltage proof and insulation resistance testsof connectors 60130-9 IEC-08
Table 32 โ€“ Dimensions of gauge for voltage proof and insulation resistance tests of connectors 60130-9 IEC-08
46 5.5 Gauge for voltage proof and contact resistance tests of connectors 60130-9 IEC-08
Figure 34 โ€“ Gauge for voltage proof and contact resistance testsof connectors 60130-9 IEC-08
Table 33 โ€“ Dimensions of gauge for voltage proof and contact resistance tests of connectors 601309 IEC08
47 6 Characteristics
6.1 Rated values
6.2 Climatic category
7 Schedule for type tests
Table 34 โ€“ Climatic category
Table 35 โ€“ Test group for all specimens
48 Table 36 โ€“ Test group for the first lot
49 Table 37 โ€“ Test group for the second and third lot
50 Table 38 โ€“ Test group for the fourth lot
Table 39 โ€“ Test group for switches in 60130-9 IEC-08
51 Annex A (normative)
Description of the connectors
54 Annex B (normative)
Measurement of individual contacts (resilient contacts only)
55 Annex C (informative)
Examples of circuitry of connector with switch
Figure C.1 โ€“ Free connector 60130-9 IEC-05 inserted in position A
Figure C.2 โ€“ Free connector 60130-9 IEC-05 inserted in position B
56 Bibliography
BS EN 60130-9:2011
$198.66