Shopping Cart

No products in the cart.

BS EN 61158-4-18:2012

$167.15

Industrial communication networks. Fieldbus specifications – Data-link layer protocol specification. Type 18 elements

Published By Publication Date Number of Pages
BSI 2012 40
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weโ€™re here to assist you 24/7.
Email:[email protected]

IEC 61158-4-18:2010 specifies the protocol which provides communication opportunities to all participating data-link entities in a synchronously-starting cyclic manner, according to a pre-established schedule, and in a cyclic or acyclic asynchronous manner, as requested each cycle by each of those data-link entities. The described procedures are applicable to instances of communication between systems which support time-critical communications services within the data-link layer of the OSI or fieldbus reference models, and which require the ability to interconnect in an open systems interconnection environment. Profiles provide a simple multi-attribute means of summarizing an implementation’s capabilities, and thus its applicability to various time-critical communications needs. This bilingual version (2012-08) corresponds to the monolingual English version, published in 2010-08. This second edition cancels and replaces the first edition published in 2007 and constitutes a technical revision. The main changes with respect to the previous edition are: Editorial improvements and Addition of cyclic data segmenting.

PDF Catalog

PDF Pages PDF Title
6 CONTENTS
9 INTRODUCTION
10 1 Scope
1.1 General
1.2 Specifications
1.3 Procedures
11 1.4 Applicability
1.5 Conformance
2 Normative references
3 Terms, definitions, symbols, abbreviations and conventions
3.1 Reference model terms and definitions
12 3.2 Type 18: Symbols
3.3 Type 18: Additional conventions
4 DL-protocol overview
4.1 Introduction
13 4.2 Polled DLE classes
4.3 Packed DLE classes
5 DLPDU encoding and transmission
5.1 DL โ€“ PhL interface
14 5.2 DLPDU transmission encoding
Figure 1 โ€“ HDLC flag
15 Tables
Table 1 โ€“ HDLC convention summary
16 6 DLPDU โ€“ basic structure
6.1 Overview
6.2 Address field
Table 2 โ€“ HDLC exception summary
Table 3 โ€“ Master-polled DLE address octet 0
17 6.3 Status field
Table 4 โ€“ Slave-polled DLE address octet 0
Table 5 โ€“ Master-packed DLE address octet 0
18 Table 6 โ€“ Master-polled DLE status octet 0
Table 7 โ€“ Master-polled DLE status octet 1
19 6.4 Data field
Table 8 โ€“ Slave-polled DLE status octet 0
Table 9 โ€“ slave-polled DLE status octet 1
Table 10 โ€“ Slave-packed DLE status
20 Table 11 โ€“ DLPDU โ€“ Master-polled DLE acyclic data field
21 7 DLPDU โ€“ Detailed structure, segmenting and reassembly
Table 12 โ€“ DLPDU โ€“ Slave-polled DLE acyclic data field
22 Table 13 โ€“ Example master-polled DLE RY contiguous data field
Table 14 โ€“ Example slave-polled DLE RX contiguous data field
Table 15 โ€“ Example master-polled DLE RWw contiguous data field
Table 16 โ€“ Example slave-polled DLE RWr contiguous data field
23 Table 17 โ€“ Bit-oriented segment header
24 Table 18 โ€“ Polled DLE acyclic segment number field
Table 19 โ€“ Slave-polled DLE acyclic data type and sequence field
25 8 Data transmission methods
8.1 Overview
8.2 Master-polled method
Table 20 โ€“ DLPDU โ€“ Polled class poll with data
Table 21 โ€“ Slave-polled DLE response timeout
26 8.3 Level A slave-polled method
Table 22 โ€“ DLPDU โ€“ Poll
Table 23 โ€“ DLPDU โ€“ End of cycle
Table 24 โ€“ slave-polled DLE request timeout
27 8.4 Level B slave-polled method
8.5 Level C slave-polled method
Table 25 โ€“ DLPDU โ€“ Level A poll response
Table 26 โ€“ DLPDU โ€“ Level B poll response
28 8.6 Master-packed method
Table 27 โ€“ DLPDU โ€“ Level C poll response
Table 28 โ€“ DLPDU โ€“ Packed class poll with data
Table 29 โ€“ Slave-packed DLE response timeout
29 8.7 Slave-packed method
Table 30 โ€“ Slave-packed DLE request timeout
Table 31 โ€“ DLPDU โ€“ Packed class poll response
30 9 DL-management โ€“ procedures
9.1 Overview
9.2 Establish master-polled DLE procedure
Table 32 โ€“ Slave-packed DLE time constraints
Table 33 โ€“ DLPDU โ€“ Poll with test data
31 9.3 Establish slave-polled DLE procedure
Table 34 โ€“ Slave-polled DLE response timeout
Table 35 โ€“ DLPDU โ€“ Poll test
Table 36 โ€“ Slave-polled DLE request timeout
32 Table 37 โ€“ DLPDU โ€“ Poll test response
Table 38 โ€“ Slave-polled DLE configuration parameter
33 9.4 Establish master-packed DLE procedure
Table 39 โ€“ DLPDU โ€“ Baud rate synchronization
Table 40 โ€“ DLPDU โ€“ Poll test
Table 41 โ€“ Slave-packed DLE response timeout
34 9.5 Establish slave-packed DLE procedure
Table 42 โ€“ Slave-packed DLE number of occupied DLE station slots
Table 43 โ€“ Slave-packed DLE baud rate synchronization timeout
35 9.6 Release connection procedure
9.7 Suspend connection procedure
9.8 Resume connection procedure
Table 44 โ€“ Slave-packed DLE Master timeout
Table 45 โ€“ DLPDU โ€“ Packed poll test response
36 9.9 Activate standby Master procedure
37 Bibliography
BS EN 61158-4-18:2012