BS EN 61241-17:2005

$142.49

Electrical apparatus for use in the presence of combustible dust – Inspection and maintenance of electrical installations in hazardous areas (other than mines)

Published By Publication Date Number of Pages
BSI 2005 30
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 61241 is intended to be applied by users and covers factors directly related to the inspection and maintenance of electrical installations within hazardous areas only. It does not include conventional requirements for electrical installations, nor the testing and certification of electrical apparatus. This standard supplements the requirements laid down in IEC 60364-6-61. NOTE: The text is based on IEC 60079-17

PDF Catalog

PDF Pages PDF Title
7 Scope
Normative references
8 Terms and definitions
10 General requirements
Documentation
Qualification of personnel
Inspections
General
11 Types of inspection
Grades of inspection
12 Regular periodic inspections
Continuous supervision by skilled persons
Concept
13 Objectives
Responsibilities
Technical persons with executive function
Skilled personnel
14 Frequency of inspection
Documents
Training
Maintenance requirements
Remedial measures and alterations to apparatus
15 Maintenance of flexible cables
Withdrawal from service
Fastenings and tools
Environmental conditions
16 Isolation of apparatus
Installations other than intrinsically safe circuits
17 Intrinsically safe installations
18 Earthing and equipotential bonding
Conditions of use
Movable apparatus and its connections
Inspection schedules (Tables 1 to 3)
Apparatus is appropriate to area classification
Apparatus maximum surface temperature is correct
Apparatus circuit identification
19 Cable entry devices
Type of cable is appropriate
Sealing
Fault loop impedance or earthing resistance
Insulation resistance
Overloads
Additional inspection schedule requirements
Type of protection “iD” – Intrinsic safety (see Table 2 and
General
20 Documentation
Labelling
Unauthorized modifications
Associated apparatus (safety interface) between intrinsicall
Cables
Cable screens
21 Point-to-point connections
Earth continuity of non-galvanically isolated circuits
Earth connections to maintain the integrity of the intrinsic
Intrinsically safe circuit earthing and/or insulation
Separation between intrinsically safe and non-intrinsically
22 Type of protection “pD” – Pressurized enclosure (see Table 3
Apparatus used in zone 22
Types of protection “mD” (encapsulation)
23 Typical inspection schedules
BS EN 61241-17:2005