Shopping Cart

No products in the cart.

BS EN 61280-2-2:2012:2015 Edition

$142.49

Fibre optic communication subsystem test procedures – Digital systems. Optical eye pattern, waveform and extinction ratio measurement

Published By Publication Date Number of Pages
BSI 2015 32
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This standard specifies a gauging system for metric taper external threads and mating parallel internal threads as specified in DIN 158-1.

Gauging of parallel internal threads is to be carried out as specified in ISO 1502.

PDF Catalog

PDF Pages PDF Title
6 CONTENTS
8 1 Scope
2 Normative references
3 Terms and definitions
9 4 Apparatus
4.1 General
10 4.2 Reference receiver definition
4.3 Time-domain optical detection system
4.3.1 Overview
Figure 1 – Optical eye pattern, waveform and extinction ratio measurement configuration
11 4.3.2 Optical-to-electrical (O/E) converter
4.3.3 Linear-phase low-pass filter
12 4.3.4 Oscilloscope
Figure 2 – Oscilloscope bandwidths commonly used in eye pattern measurements
13 4.4 Overall system response
4.5 Oscilloscope synchronization system
4.5.1 General
Table 1 – Frequency response characteristics
14 4.5.2 Triggering with a clean clock
4.5.3 Triggering using a recovered clock
15 4.5.4 Triggering directly on data
Figure 3 – PLL jitter transfer function and resulting observed jitter transfer function
16 4.6 Pattern generator
4.7 Optical power meter
4.8 Optical attenuator
4.9 Test cord
5 Signal under test
6 Instrument set-up and device under test set-up
17 7 Measurement procedures
7.1 Overview
7.2 Extinction ratio measurement
7.2.1 Configure the test equipment
7.2.2 Measurement procedure
18 7.2.3 Extinction ratio calculation
Figure 4 – Histograms centred in the central 20 % of the eye used to determine the mean logic one and 0 levels, b1 and b0
19 7.3 Eye amplitude
7.4 Optical modulation amplitude (OMA) measurement using the square wave method
7.4.1 General
7.4.2 Oscilloscope triggering
7.4.3 Amplitude histogram, step 1
20 7.4.4 Amplitude histogram, step 2
7.4.5 Calculate OMA
7.5 Contrast ratio (for RZ signals)
7.6 Jitter measurements
Figure 5 – OMA measurement using the square wave method
21 7.7 Eye width
7.8 Duty cycle distortion (DCD)
22 7.9 Crossing percentage
Figure 6 – Construction of the duty cycle distortion measurement
23 7.10 Eye height
7.11 Q-factor/signal-to-noise ratio (SNR)
7.12 Rise time
Figure 7 – Construction of the crossing percentage measurement
24 7.13 Fall time
Figure 8 – Construction of the risetime measurement with no reference receiver filtering
25 8 Eye-diagram analysis using a mask
8.1 Eye mask testing using the ‘no hits’ technique
Figure 9 – Illustrations of several RZ eye-diagram parameters
26 8.2 Eye mask testing using the ‘hit-ratio’ technique
Figure 10 – Basic eye mask and coordinate system
28 9 Test result
9.1 Required information
9.2 Available information
9.3 Specification information
Figure 11 – Mask margins at different sample population sizes
29 Bibliography
BS EN 61280-2-2:2012
$142.49