Shopping Cart

No products in the cart.

BS EN 62386-210:2011

$198.66

Digital addressable lighting interface – Particular requirements for control gear. Sequencer (device type 9)

Published By Publication Date Number of Pages
BSI 2011 66
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weโ€™re here to assist you 24/7.
Email:[email protected]

This International Standard specifies a protocol and test procedures for the control by digital signals of electronic control gear working as automatic sequencers.

PDF Catalog

PDF Pages PDF Title
6 English

CONTENTS
9 INTRODUCTION
10 1 Scope
2 Normative references
3 Terms and definitions
11 4 General description
5 Electrical specifications
6 Interface power supply
7 Transmission protocol structure
8 Timing
9 Method of operation
13 Tables

Table 1 โ€“ Access to the sequencer variables
14 Table 2 โ€“ Sequencer programming example
15 Figures

Figure 1 โ€“ Timing example for an automatic sequence
16 10 Declaration of variables
Table 3 โ€“ Declaration of variables
17 11 Definition of commands
18 Figure 2 โ€“ Application extended configuration command sequence example
25 Table 4 โ€“ Summary of the application extended command set
26 12 Test procedures
Figure 3 โ€“ Test sequence “Physical address allocation”
27 Figure 4 โ€“ Test sequence “QUERY FEATURES”
28 Figure 5 โ€“ Test sequence “Configure POINT N”
Table 5 โ€“ Parameters for test sequence “Configure POINT N”
29 Figure 6 โ€“ Test sequence “Configuration โ€“ sent twice”
Table 6 โ€“ Parameters for test sequence “Configuration โ€“ sent twice”
30 Figure 7 โ€“ Test sequence “Configuration โ€“ time-out”
Table 7 โ€“ Parameters for test sequence “Configuration โ€“ time-out”
31 Figure 8 โ€“ Test sequence “Configuration โ€“ command in-between 1”
Table 8 โ€“ Parameters for test sequence “Configuration โ€“ command in-between 1”
32 Figure 9 โ€“ Test sequence “Configuration โ€“ command in-between 2”
Table 9 โ€“ Parameters for test sequence “Configuration โ€“ command in-between 2”
33 Figure 10 โ€“ Test sequence “COPY TO POINT N”
Table 10 โ€“ Parameters for test sequence “COPY TO POINT N”
34 Figure 11 โ€“ Test sequence “COPY TO POINT N โ€“ sent twice”
Table 11 โ€“ Parameters for test sequence “COPY TO POINT N โ€“ sent twice”
35 Figure 12 โ€“ Test sequence “COPY TO POINT N โ€“ time-out”
Table 12 โ€“ Parameters for test sequence “COPY TO POINT N โ€“ time-out”
36 Figure 13 โ€“ Test sequence “COPY TO POINT N โ€“ command in-between”
Table 13 โ€“ Parameters for test sequence “COPY TO POINT N โ€“ command in-between”
37 Figure 14 โ€“ Test sequence “CHANNEL SELECTION”
38 Figure 15 โ€“ Test sequence “CHANNEL SELECTION โ€“ sent twice / time-out”
39 Figure 16 โ€“ Test sequence “CHANNEL SELECTION โ€“ command in-between”
Table 16 โ€“ Parameters for test sequence “CHANNEL SELECTION โ€“command in-between”
40 Figure 17 โ€“ Test sequence “CONFIGURE CONTROL N”
41 Figure 18 โ€“ Test sequence “CONFIGURE CONTROL N โ€“ sent twice / time-out”
42 Figure 19 โ€“ Test sequence “CONFIGURE CONTROL N โ€“ command in-between”
Table 19 โ€“ Parameters for test sequence “CONFIGURE CONTROL N โ€“command in-between”
43 Figure 20 โ€“ Test sequence “ENABLE DEVICE TYPE: Application extended commands”
Table 20 โ€“ Parameters for test sequence “ENABLE DEVICE TYPE: Application extended commands”
44 Figure 21 โ€“ Test sequence ‘ENABLE DEVICE TYPE: Application extended configuration commands 1’
Table 21 โ€“ Parameters for test sequence ‘ENABLE DEVICE TYPE: Application extended configuration commands 1’
45 Figure 22 โ€“ Test sequence ‘ENABLE DEVICE TYPE: Application extended configuration commands 2’
46 Figure 23 โ€“ Subsequence ‘Configure sequence’
Table 23 โ€“ Parameters for subsequence ‘Configure sequence’
47 Figure 24 โ€“ Test sequence ‘GO TO POINT N’
Table 24 โ€“ Parameters for test sequence ‘GO TO POINT N’
48 Figure 25 โ€“ Test sequence ‘GO TO NEXT POINT’
49 Figure 26 โ€“ Test sequence ‘GO TO PREVIOUS POINT’
50 Figure 27 โ€“ Test sequence ‘Automatic sequence’
Table 27 โ€“ Parameters for test sequence ‘Automatic sequence’
51 Figure 28 โ€“ Timing diagram for test ‘Automatic sequence’
52 Figure 29 โ€“ Test sequence ‘Automatic sequence โ€“ pointer’
Table 29 โ€“ Parameters for test sequence ‘Automatic sequence โ€“ pointer’
53 Figure 30 โ€“ Test sequence ‘Automatic sequence โ€“ number of runs’
Table 30 โ€“ Parameters for test sequence ‘Automatic sequence โ€“ number of runs’
54 Figure 31 โ€“ Test sequence ‘Automatic sequence โ€“ stopped by command’
Table 31 โ€“ Parameters for test sequence ‘Automatic sequence โ€“ stopped by command’
55 Figure 32 โ€“ Test sequence ‘Sequencer performance’
Figure 33 โ€“ Template for ‘Sequencer performance’
56 Figure 34 โ€“ Test sequence ‘START AT POINT N โ€“ number of runs’
Table 34 โ€“ Parameters for test sequence ‘START AT POINT N โ€“ number of runs’
57 Figure 35 โ€“ Test sequence ‘RESET SEQUENCER’
58 Figure 36 โ€“ Test sequence ‘RESET SEQUENCER โ€“ send twice / time-out’
59 Figure 37 โ€“ Test sequence ‘RESET SEQUENCER โ€“ command in-between’
Table 37 โ€“ Parameters for test sequence ‘RESET SEQUENCER โ€“ command in-between’
60 Figure 38 โ€“ Test sequence ‘RESET CONTROL N’
61 Figure 39 โ€“ Test sequence ‘FAULTY CHANNEL’
Table 39 โ€“ Parameters for test sequence ‘FAULTY CHANNEL’
62 Figure 40 โ€“ Test sequence ‘QUERY EXTENDED VERSION NUMBER’
63 Figure 41 โ€“ Test sequence ‘RESERVED APPLICATION EXTENDED COMMANDS’
Table 41 โ€“ Parameters for test sequence ‘RESERVED APPLICATION EXTENDED COMMANDS’
64 Bibliography
BS EN 62386-210:2011
$198.66