Shopping Cart

No products in the cart.

BS EN IEC 61784-1-3:2023

$215.11

Industrial networks. Profiles – Part 1-3. Fieldbus profiles. Communication Profile Family 3

Published By Publication Date Number of Pages
BSI 2023 122
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
2 undefined
5 Annex ZA (normative)Normative references to international publicationswith their corresponding European publications
7 English
CONTENTS
11 FOREWORD
13 INTRODUCTION
14 1 Scope
2 Normative references
15 3 Terms, definitions, abbreviated terms, symbols, and conventions
3.1 Terms and definitions
3.2 Abbreviations and symbols
3.2.1 Common abbreviations and symbols
3.2.2 Other abbreviations and symbols
3.3 Conventions
16 4 CPF 3 (PROFIBUS & PROFINET)
4.1 General overview
Tables
Table 1 – CPF 3: overview of profile sets
17 4.2 CP 3/1 (PROFIBUS DP)
4.2.1 Physical layer
Figure 1 – CP 3/2 Slave devices usable in applications
Table 2 – CP 3/1: PhL selection
19 4.2.2 Data-link layer
Table 3 – CP 3/1: PhL selection of Clause 3
Table 4 – CP 3/1: PhL selection of Clause 4
20 Table 5 – CP 3/1: General DLL service selection
21 Table 6 – CP 3/1: DLL service selection for DP-V0 master (class 1)
22 Table 7 – CP 3/1: DLM service selection for DP-V0 master (class 1)
23 Table 8 – CP 3/1: DLL service selection for DP-V1 master (class 1)
24 Table 9 – CP 3/1: DLM service selection for DP-V1 master (class 1)
Table 10 – CP 3/1: DLL service selection for DP-V0 master (class 2)
25 Table 11 – CP 3/1: DLL service selection for DP-V1 master (class 2)
27 Table 12 – CP 3/1: DLL service selection for DP-V0 slave
28 Table 13 – CP 3/1: DLM service selection for DP-V0 slave
29 Table 14 – CP 3/1: DLL service selection for DP-V1 slave
30 Table 15 – CP 3/1: DLM service selection for DP-V1 slave
31 Table 16 – CP 3/1: General DLL protocol selection
Table 17 – CP 3/1: DLL protocol selection of Clause 5
32 Table 18 – CP 3/1: DLL protocol selection of Clause 6
Table 19 – CP 3/1: DLL protocol selection of Clause 7
33 Table 20 – CP 3/1: Time variable selection for DP-V0 master (class 1)
34 Table 21 – CP 3/1: Timer and counter selection for DP-V0 master (class 1)
Table 22 – CP 3/1: DLPDU selection for DP-V0 master (class 1)
35 Table 23 – CP 3/1: MAC state selection for DP-V0 master (class 1)
36 Table 24 – CP 3/1: Time selection for DP-V1 master (class 1)
37 Table 25 – CP 3/1: Timer and counter selection for DP-V1 master (class 1)
Table 26 – CP 3/1: DLPDU selection for DP-V1 master (class 1)
38 Table 27 – CP 3/1: MAC state selection for DP-V1 master (class 1)
Table 28 – CP 3/1: CS protocol selection for DP-V1 master (class 1)
39 Table 29 – CP 3/1: Time selection for DP-V1 master (class 2)
Table 30 – CP 3/1: Timer and counter selection for DP-V1 master (class 2)
40 Table 31 – CP 3/1: DLPDU selection for DP-V1 master (class 2)
Table 32 – CP 3/1: Time selection for DP-V0 slave
41 Table 33 – CP 3/1: Timer and counter selection for DP-V0 slave
Table 34 – CP 3/1: DLPDU selection for DP-V0 slave
42 Table 35 – CP 3/1: MAC state selection for DP-V0 slave
Table 36 – CP 3/1: Time selection for DP-V1 slave
43 Table 37 – CP 3/1: Timer and counter selection for DP-V1 slave
Table 38 – CP 3/1: DLPDU selection for DP-V1 slave
44 4.2.3 Application layer
Table 39 – CP 3/1: CS protocol selection for DP-V1 slave
Table 40 – CP 3/1, 3/2: AL service selection
45 Table 41 – CP 3/1, 3/2: AL service selection of Clause 6
Table 42 – CP 3/1, 3/2: AL service selection of I/O data ASE
46 Table 43 – CP 3/1, 3/2: AL service selection of Diagnosis ASE
Table 44 – CP 3/1, 3/2: AL service selection of Context ASE
47 Table 45 – CP 3/1, 3/2: AL service selection of Management ASE
48 Table 46 – CP 3/1, 3/2: AL service selection of AR ASE
49 Table 47 – CP 3/1, 3/2: AL service selection of Clause 6
Table 48 – CP 3/1, 3/2: AL service selection of Process data ASE
50 Table 49 – CP 3/1, 3/2: AL service selection of I/O data ASE
Table 50 – CP 3/1, 3/2: AL service selection of Alarm ASE
Table 51 – CP 3/1, 3/2: AL service selection of Context ASE
51 Table 52 – CP 3/1, 3/2: AL service selection of Load region ASE
Table 53 – CP 3/1, 3/2: AL service selection of Function invocation ASE
Table 54 – CP 3/1, 3/2: AL service selection of Time ASE
52 Table 55 – CP 3/1, 3/2: AL service selection of AR ASE
53 Table 56 – CP 3/1, 3/2: AL service selection of Clause 6
Table 57 – CP 3/1, 3/2: AL service selection of I/O data ASE
54 Table 58 – CP 3/1, 3/2: AL service selection of Diagnosis ASE
Table 59 – CP 3/1, 3/2: AL service selection of Context ASE
Table 60 – CP 3/1, 3/2: AL service selection of Management ASE
55 Table 61 – CP 3/1, 3/2: AL service selection of AR ASE
56 Table 62 – CP 3/1, 3/2: AL service selection of Clause 6
Table 63 – CP 3/1, 3/2: AL service selection of Process data ASE
57 Table 64 – CP 3/1, 3/2: AL service selection of Context ASE
Table 65 – CP 3/1, 3/2: AL service selection of Load region ASE
58 Table 66 – CP 3/1, 3/2: AL service selection of Function invocation ASE
Table 67 – CP 3/1, 3/2: AL service selection of Time ASE
59 Table 68 – CP 3/1, 3/2: AL service selection of AR ASE
60 Table 69 – CP 3/1, 3/2: AL service selection of Clause 6
61 Table 70 – CP 3/1, 3/2: AL service selection of I/O data ASE
62 Table 71 – CP 3/1, 3/2: AL service selection of Diagnosis ASE
63 Table 72 – CP 3/1, 3/2: AL service selection of Context ASE
64 Table 73 – CP 3/1, 3/2: AL service selection of AR ASE
65 Table 74 – CP 3/1, 3/2: AL service selection of Clause 6
Table 75 – CP 3/1, 3/2: AL service selection of Process data ASE
66 Table 76 – CP 3/1, 3/2: AL service selection of I/O data ASE
Table 77 – CP 3/1, 3/2: AL service selection of diagnosis ASE
67 Table 78 – CP 3/1, 3/2: AL service selection of Alarm ASE
Table 79 – CP 3/1, 3/2: AL service selection of Context ASE
68 Table 80 – CP 3/1, 3/2: AL service selection of Load region ASE
Table 81 – CP 3/1, 3/2: AL service selection of Function invocation ASE
Table 82 – CP 3/1, 3/2: AL service selection of Time ASE
69 Table 83 – CP 3/1, 3/2: AL service selection of AR ASE
70 Table 84 – CP 3/1, 3/2: AL protocol selection
Table 85 – CP 3/1, 3/2: AL protocol selection of Clause 4 to 11
72 Table 86 – CP 3/1, 3/2: AL protocol selection of APDUs
73 Table 87 – CP 3/1, 3/2: AL protocol selection of FSPM services primitives
74 Table 88 – CP 3/1, 3/2: AL protocol selection of DMPM services primitives
Table 89 – CP 3/1, 3/2: AL protocol selection of Clause 4 to 11
76 Table 90 – CP 3/1, 3/2: AL protocol selection of APDUs
77 Table 91 – CP 3/1, 3/2: AL protocol selection of FSPM services primitives
79 Table 92 – CP 3/1, 3/2: AL protocol selection of DMPM services primitives
Table 93 – CP 3/1, 3/2: AL protocol selection of Clause 4 to 6
81 Table 94 – CP 3/1, 3/2: AL protocol selection of APDUs
82 Table 95 – CP 3/1, 3/2: AL protocol selection of FSPM services primitives
Table 96 – CP 3/1, 3/2: AL protocol selection of DMPM services primitives
83 Table 97 – CP 3/1, 3/2: AL protocol selection of Clause 4 to 11
85 Table 98 – CP 3/1, 3/2: AL protocol selection of APDUs
87 Table 99 – CP 3/1, 3/2: AL protocol selection of FSPM services primitives
88 Table 100 – CP 3/1, 3/2: AL protocol selection of DMPM services primitives
Table 101 – CP 3/1, 3/2: AL protocol selection of Clause 4 to 11
90 Table 102 – CP 3/1, 3/2: AL protocol selection of APDU selection
91 Table 103 – CP 3/1, 3/2: AL protocol selection of FSPM services primitives
92 Table 104 – CP 3/1, 3/2: AL protocol selection of DMPM services primitives
Table 105 – CP 3/1, 3/2: AL protocol selection of Clause 4 to 11
94 Table 106 – CP 3/1, 3/2: AL protocol selection of APDUs
96 Table 107 – CP 3/1, 3/2: AL protocol selection of FSPM services primitives
98 Table 108 – CP 3/1, 3/2: AL protocol selection of DMPM services primitives
100 4.3 CP 3/2 (PROFIBUS PA)
4.3.1 Physical layer
Table 109 – CP 3/2: PhL selection
102 Table 110 – CP 3/2: PhL selection of Clause 12 for devices and their MAUs
103 Table 111 – CP 3/2: PhL selection of recommended IS parameters
Table 112 – CP 3/2: PhL selection of Clause 21 for devices and their MAUs
104 4.3.2 Data-link layer
105 Table 113 – CP 3/2: General DLL protocol selection
Table 114 – CP 3/2: DLL protocol selection of Clause 4
106 Table 115 – CP 3/2: DLL protocol selection of Clause 5
Table 116 – CP 3/2: DLL protocol selection of Clause 6
107 Table 117 – CP 3/2: DLL protocol selection of Clause 7
108 Table 118 – CP 3/2: Time variable selection for DP-V0 master (class 1)
Table 119 – CP 3/2: Timer and counter selection for DP-V0 master (class 1)
109 Table 120 – CP 3/2: DLPDU selection for DP-V0 master (class 1)
110 Table 121 – CP 3/2: Time variable selection for DP-V1 master (class 1)
111 Table 122 – CP 3/2: Timer and counter selection for DP-V1 master (class 1)
Table 123 – CP 3/2: DLPDU selection for DP-V1 master (class 1)
112 Table 124 – CP 3/2: Time variable selection for DP-V1 master (class 2)
113 Table 125 – CP 3/2: Timer and counter selection for DP-V1 master (class 2)
Table 126 – CP 3/2: DLPDU selection for DP-V1 master (class 2)
114 Table 127 – CP 3/2: Time variable selection for DP-V0 slave
Table 128 – CP 3/2: Timer and counter selection for DP-V0 slave
115 Table 129 – CP 3/2: DLPDU selection for DP-V0 slave
Table 130 – CP 3/2: Time variable selection for DP-V1 slave
116 4.3.3 Application layer
Table 131 – CP 3/2: Timer and counter selection for DP-V1 slave
Table 132 – CP 3/2: DLPDU selection for DP-V1 slave
117 Annex A (informative)CPF 3 (PROFIBUS & PROFINET) communication concepts
A.1 Basic characteristics
A.1.1 General
A.1.2 PROFIBUS DP
118 A.2 Physical layer profiles
A.3 Communication feature list (GSD)
120 Bibliography
BS EN IEC 61784-1-3:2023
$215.11