BS EN ISO 13934-1:2013
$142.49
Textiles. Tensile properties of fabrics – Determination of maximum force and elongation at maximum force using the strip method
Published By | Publication Date | Number of Pages |
BSI | 2013 | 24 |
This part of ISO 13934 specifies a procedure to determine the maximum force and elongation at maximum force of textile fabrics using a strip method.
NOTE ISO 13934-2 describes the method known as the grab method. For informative references, see Bibliography.
The method is mainly applicable to woven textile fabrics, including fabrics which exhibit stretch characteristics imparted by the presence of an elastomeric fibre, mechanical, or chemical treatment. It can be applicable to fabrics produced by other techniques. It is not normally applicable to geotextiles, nonwovens, coated fabrics, textile-glass woven fabrics, and fabrics made from carbon fibres or polyolefin tape yarns (see Bibliography).
The method specifies the determination of the maximum force and elongation at maximum force of test specimens in equilibrium with the standard atmosphere for testing, and of test specimens in the wet state.
The method is restricted to the use of constant rate of extension (CRE) testing machines.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | Foreword |
7 | Introduction |
9 | Section sec_1 Section sec_2 Section sec_3 1 Scope 2 Normative references 3 Terms and definitions |
11 | Table tab_a Figure fig_1 Section sec_4 4 Principle |
12 | Section sec_5 Section sec_6 Section sec_6.1 Section sec_6.1.1 Section sec_6.1.2 Section sec_6.1.3 Section sec_6.1.4 Section sec_6.1.5 Section sec_6.1.6 5 Sampling 6 Apparatus 6.1 CRE machine |
13 | Section sec_6.2 Section sec_6.3 Section sec_6.4 Section sec_6.5 Section sec_7 Section sec_8 Section sec_8.1 Section sec_8.2 Section sec_8.3 7 Atmosphere for conditioning and testing 8 Preparation of test specimen 8.1 General 8.2 Dimensions 8.3 Preparation of test specimens |
14 | Section sec_8.4 Section sec_8.4.1 Section sec_8.4.2 Section sec_9 Section sec_9.1 Section sec_9.2 Table tab_1 Section sec_9.3 Section sec_9.3.1 8.4 Wet test specimens 9 Procedure 9.1 Gauge length 9.2 Rate of extension or elongation 9.3 Mounting of test specimens |
15 | Section sec_9.3.2 Section sec_9.4 Section sec_9.4.1 Section sec_9.4.2 9.4 Operation |
16 | Section sec_9.5 Section sec_10 Section sec_11 9.5 Tests on wet test specimens 10 Calculation and expression of results 11 Test report |
18 | Annex sec_A Annex sec_A.1 Table tab_A.1 Annex sec_A.2 Annex A (informative) Suggested procedure for sampling |
19 | Annex sec_B Table tab_f Figure fig_B.1 Annex B (informative) Locations of test specimens cut from a laboratory sample |
20 | Reference ref_1 Reference ref_2 Reference ref_3 Reference ref_4 Reference ref_5 Reference ref_6 Reference ref_7 Bibliography |