Shopping Cart

No products in the cart.

BS ISO 10349-13:2002

$86.31

Photography. Photographic-grade chemicals. Test methods – Determination of pH

Published By Publication Date Number of Pages
BSI 2002 12
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of ISO 10349 specifies a general test method for the determination of pH of solutions of photographic-grade chemicals to within ± 0,1 pH units.

This method is not intended to monitor the pH of formulated solutions used directly in photographic processing, e.g. developers.

PDF Catalog

PDF Pages PDF Title
3 TitlePage – Photography�— Photographic-grade chemicals�— Test methods�—
5 TableofContent – Contents Page
6 Foreword – Foreword
7 Scope – 1��� Scope
NormativeReference – 2��� Normative reference
Clause1 – 4��� Hazards
Clause1 – 5��� Reagents
UntitledSubclause2 – 5.1��� Calibration buffers
UntitledSubclause3 – 5.1.1��� pH�4,0 buffer solution
8 UntitledSubclause3 – 5.1.2��� pH�7,0 buffer solution
UntitledSubclause3 – 5.1.3��� pH�10,0 buffer solution
Clause1 – 6��� Apparatus
UntitledSubclause2 – 6.1��� pH meter
UntitledSubclause2 – 6.2��� Electrodes
UntitledSubclause2 – 6.3��� Constant temperature water-bath
Clause1 – 7��� Sampling
Clause1 – 8��� Procedure
Subclause2 – 8.1��� Calibration and standardization
UntitledSubclause3 – 8.1.1��� Consult the manufacturer’s instruction manual for proper set-up and…
UntitledSubclause3 – 8.1.2��� Rinse the electrodes (
9 UntitledSubclause3 – 8.1.3��� Rinse the electrodes with water and blot dry.
UntitledSubclause3 – 8.1.4��� Rinse the electrodes with water; blot dry and proceed with sample m…
UntitledSubclause3 – 8.1.5��� Calibration of the pH meter shall be done just prior to sample meas…
UntitledSubclause3 – 8.1.6��� Calibration buffers (
Subclause2 – 8.2��� pH measurement
UntitledSubclause3 – 8.2.1��� After temperature equilibration and calibration of the pH meter for…
UntitledSubclause3 – 8.2.2��� Weigh the test portion specified in the appropriate International S…
UntitledSubclause3 – 8.2.3��� Rinse the electrodes with water and blot dry. Immerse the electrode…
UntitledSubclause3 – 8.2.4��� Record the pH of the solution to the nearest 0,1�pH units.
Clause1 – 9��� Test report
10 AnnexInformative – Electrode care
Clause1 – A.1��� Storage
Clause1 – A.2��� pH electrodes�— Preconditioning/rejuvenation
Clause1 – A.3��� Reference electrode�— Care/rejuvenation
Subclause2 – A.3.1��� Calomel reference electrode
Subclause2 – A.3.2��� Silver/silver chloride electrodes
BS ISO 10349-13:2002