BS ISO 12963:2017+A1:2020:2021 Edition
$167.15
Gas analysis. Comparison methods for the determination of the composition of gas mixtures based on one- and two-point calibration
Published By | Publication Date | Number of Pages |
BSI | 2021 | 34 |
This document provides methods for
-
calibrating an instrument with one or two calibration gas mixtures,
-
determining the composition of a gas sample, and
-
evaluating the uncertainty of the composition of the gas sample in relation to the uncertainty of the composition of the calibration gases used and the contribution of the measurement process.
This document sets requirements to, and acceptance criteria for, the utilization of different measurement calibration designs with a limited (i.e. minimum) number of calibration gas mixtures used in calibration.
The methods in this document are described for amount-of-substance fractions, but are also applicable for other composition quantities (such as mass fractions, volume fractions or concentrations).
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
6 | Foreword |
7 | Introduction |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 Symbols 5 Abbreviated terms |
11 | 6 Principle 6.1 General requirements |
12 | 6.2 Calibration methods 7 Main procedure 7.1 Pre-requisites 7.2 Sequence of operations (overview) |
13 | 7.3 Calibration and measurement designs 7.3.1 General |
14 | 7.3.2 Single-point exact-match calibration (SPEM) 7.3.3 Single-point through origin calibration (SPO) |
15 | 7.3.4 Two-point calibration with a blank (TPB) 7.3.5 Two-point calibration with bracketing (TPC) |
16 | 7.3.6 Multipoint calibration (MPC) 8 Performance evaluation of the measuring system 8.1 General |
18 | 8.2 Sources of performance evaluation data and alternative approach 8.2.1 Performance evaluation other than in-house |
19 | 8.2.2 Alternative for performance evaluation 9 Quality assurance measures 9.1 Validation of the assumptions made 9.2 Drift/stability control of the measuring system |
20 | 10 Report of results 10.1 Calibration gas certificates 10.2 Report of analysis |
21 | Annex A (normative) System-stability check required when using exact-match and bracketing designs |
23 | Annex B (normative) Statistics and sensitivity coefficients used in Clause 7 |
25 | Annex C (normative) Alternative approach to assessing the nonlinearity contribution |
27 | Annex D (informative) Worked-out example |
30 | Annex E (informative) Using the designs without preceding system performance evaluation |
32 | Bibliography |