BS ISO 17089-1:2019

$215.11

Measurement of fluid flow in closed conduits. Ultrasonic meters for gas – Meters for custody transfer and allocation measurement

Published By Publication Date Number of Pages
BSI 2019 126
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document specifies requirements and recommendations for ultrasonic gas flowmeters (USMs), which utilize the transit time of acoustic signals to measure the flow of single phase homogenous gases in closed conduits.

This document applies to transit time ultrasonic gas flowmeters used for custody transfer and allocation metering, such as full-bore, reduced-area, high-pressure, and low-pressure meters or any combination of these. There are no limits on the minimum or maximum sizes of the meter. This document can be applied to the measurement of almost any type of gas, such as air, natural gas, and ethane.

Included are flow measurement performance requirements for meters of two accuracy classes suitable for applications such as custody transfer and allocation measurement.

This document specifies construction, performance, calibration, diagnostics for meter verification, and output characteristics of ultrasonic meters for gas flow measurement and deals with installation conditions.

NOTE

It is possible that national or other regulations apply which can be more stringent than those in this document.

PDF Catalog

PDF Pages PDF Title
2 National foreword
8 Foreword
9 Introduction
11 1 Scope
2 Normative references
3 Terms, definitions and symbols
3.1 Terms and definitions
12 3.1.1 Quantities
3.1.2 Meter design
13 3.1.3 Thermodynamic conditions
3.1.4 Statistics
15 3.2 Symbols and subscripts
17 3.3 Abbrevations
4 Principles of measurement
4.1 Basic formulae
19 4.2 Factors affecting the performance
4.3 Description of generic types
4.3.1 General
4.3.2 Transducers
20 4.3.3 Meter body and acoustic path configurations
22 4.3.4 Average velocity calculation
23 4.4 Contributions to the uncertainty in measurement
4.5 Reynolds number
4.6 USM classification
24 5 Meter characteristics
5.1 Operating conditions
5.1.1 Flow rates and gas velocities
5.1.2 Pressure
5.1.3 Temperature
5.1.4 Gas quality
25 5.2 Meter body, materials, and construction
5.2.1 Materials
5.2.2 Meter body
5.2.3 Connections
5.2.4 Dimensions
26 5.2.5 Ultrasonic transducer ports
5.2.6 Pressure tappings
5.2.7 Anti-roll provision
27 5.2.8 Flow conditioner
5.2.9 Markings
28 5.2.10 Corrosion protection
5.3 Transducers
5.3.1 Specification
5.3.2 Rate of pressure change
5.3.3 Transducer characterization
5.3.4 Path configuration
5.3.5 Marking
5.3.6 Cable
29 5.3.7 Robustness
5.4 Electronics
5.4.1 General requirements
5.4.2 Display
5.4.3 Power supply
5.4.4 Signal detection method
5.4.5 Sampling or pulsating flow
5.4.6 Signal-to-noise ratio
5.4.7 Alarm signal
5.4.8 Processing of data
30 5.4.9 Output
5.4.10 Cable jackets and insulation
5.4.11 Marking
5.5 Software
5.5.1 Firmware
31 5.5.2 MODBUS communication data specification
5.5.3 Discontinuity
5.5.4 Marking and version management
5.5.5 Monitoring and recording of measuring and diagnostic data
5.5.6 Correction functions and parameters
32 5.5.7 Inspection and verification functions
5.6 Exchange of components
5.7 Secondary measurements
5.7.1 General
5.7.2 Pressure measurement
5.7.3 Temperature measurement
34 5.8 Performance requirements
5.8.1 General
5.8.2 Accuracy requirements
35 5.8.3 Influence of pressure, temperature, and gas composition
36 5.9 Operation and installation requirements
5.9.1 General
5.9.2 Operational requirements
37 5.9.3 Installation requirements
40 5.9.4 Manual handling and transportation
5.10 Documentation
5.10.1 General
5.10.2 Generic meter documentation
41 5.10.3 Particular meter documentation
6 Test and calibration
6.1 Pressure testing and leakage testing
6.2 Individual testing — Static testing
6.2.1 General
6.2.2 Timing and time delays
6.2.3 Zero flow verification test
42 6.3 Individual testing — Flow calibration
6.3.1 General
6.3.2 Laboratory flow calibration
45 6.3.3 Judging the measurement performance of the meter
6.3.4 Adjustment and records
47 7 Type testing
7.1 General
48 7.2 Accuracy
7.3 Installation conditions
49 7.4 Path failure simulation and exchange of components
7.5 Electronics design testing
50 8 Audit trail and diagnostics for meter verification
8.1 General
8.2 USM Lifecycle Process
52 8.3 Production and Factory Acceptance Test
8.4 Initial Flow Calibration
53 8.5 Site installation and site acceptance test
8.6 Operation
54 8.7 Diagnostic warning and alarm levels in operation
8.7.1 MSOS and MSOS ratios warning & alarm levels
55 8.7.2 Velocity ratios warning & alarm levels
8.7.3 S/N ratios warning & alarm levels
8.8 Service and recalibration
8.8.1 General
56 8.8.2 Service Related Diagnostics
57 8.9 Diagnostic parameters
8.9.1 Speed of sound
59 8.9.2 Automatic gain control
8.9.3 Signal-to-noise ratio (S/N)
60 8.9.4 Acoustic signal acceptance
8.9.5 Flow profile
8.9.6 Standard deviation/turbulence
61 9 Operational practice
9.1 Temperature and pressure correction
9.1.1 Correction for the temperature
63 9.1.2 Correction for the pressure
68 Annex A (informative) Registration of error bands
69 Annex B (informative) Derivation and correction of USM errors
73 Annex C (informative) Valve characterization and noise in a metering and regulating station
84 Annex D (informative) The calibration time of ultrasonic flow meters
90 Annex E (informative) Detailed calculation of geometry-related temperature and pressure corrections
112 Annex F (normative) MODBUS communication data specification
118 Annex G (informative) Disturbance tests
120 Bibliography
BS ISO 17089-1:2019
$215.11