BSI PD CEN ISO/TR 22930-1:2021

$198.66

Evaluating the performance of continuous air monitors – Air monitors based on accumulation sampling techniques

Published By Publication Date Number of Pages
BSI 2021 62
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The use of a continuous air monitor (CAM) is mainly motivated by the need to be alerted quickly and in the most accurate way possible with an acceptable false alarm rate when a significant activity concentration value is exceeded, in order to take appropriate measures to reduce exposure of those involved.

The performance of this CAM does not only depend on the metrological aspect characterized by the decision threshold, the limit of detection and the measurement uncertainties but also on its dynamic capacity characterized by its response time as well as on the minimum detectable activity concentration corresponding to an acceptable false alarm rate.

The ideal performance is to have a minimum detectable activity concentration as low as possible associated with a very short response time, but unfortunately these two criteria are in opposition. It is therefore important that the CAM and the choice of the adjustment parameters and the alarm levels be in line with the radiation protection objectives.

The knowledge of a few factors is needed to interpret the response of a CAM and to select the appropriate CAM type and its operating parameters.

Among those factors, it is important to know the half-lives of the radionuclides involved, in order to select the appropriate detection system and its associated model of evaluation.

CAM using filter media accumulation sampling techniques are usually of two types:

  1. fixed filter;

  2. moving filter.

This document first describes the theory of operation of each CAM type i.e.:

  • the different models of evaluation considering short or long radionuclides half-lives values,

  • the dynamic behaviour and the determination of the response time.

In most case, CAM is used when radionuclides with important radiotoxicities are involved (small value of ALI). Those radionuclides have usually long half-life values.

Then the determination of the characteristic limits (decision threshold, detection limit, limits of the coverage interval) of a CAM is described by the use of long half-life models of evaluation.

Finally, a possible way to determine the minimum detectable activity concentration and the alarms setup is pointed out.

The annexes of this document show actual examples of CAM data which illustrate how to quantify the CAM performance by determining the response time, the characteristics limits, the minimum detectable activity concentration and the alarms setup.

PDF Catalog

PDF Pages PDF Title
2 undefined
5 European foreword
Endorsement notice
7 Foreword
8 Introduction
10 1 Scope
11 2 Normative references
3 Terms and definitions
13 4 Symbols
15 5 Measuring principle
16 6 Fixed-media filter monitor
6.1 Preliminary note
6.2 Study of the dynamic behaviour
6.2.1 General
17 6.2.2 Short half-life model of evaluation of the activity concentration
20 6.2.3 Long half-life radionuclide activity concentration model of evaluation
23 6.2.4 Intermediate half-life radionuclide activity concentration model of evaluation
24 6.2.5 Comparison of the three fixed filter models of evaluation
26 7 Moving filter monitor
7.1 Preliminary note
7.2 Study of the dynamic behaviour
29 7.3 Activity concentration model of evaluation
32 8 Evaluation of the characteristic limits
8.1 General
33 8.2 Fixed media filter model of evaluation
8.2.1 General
8.2.2 Definition of the model
8.2.3 Standard uncertainty
34 8.2.4 Decision threshold
35 8.2.5 Detection limit
8.2.6 Limits of the coverage interval
37 8.3 Moving filter model of evaluation
8.3.1 Definition of the measurand
8.3.2 Standard uncertainty
38 8.3.3 Decision threshold
8.3.4 Detection limit
8.3.5 Limits of the coverage interval
9 Alarms setup, minimum detectable activity concentration and PME
41 Annex A (informative) Numerical example of gross beta emitting activity concentration measurement on fixed filter
46 Annex B (informative) Numerical example of gross alpha emitting activity concentration measurement on moving filter
50 Annex C (informative) Numerical example of iodine 131 activity concentration gamma spectrometry measurement on fixed charcoal cartridge
53 Annex D (informative) Determination of the detectable activity concentration and its associated response time by the use a linear regression and statistical test method
61 Bibliography