Electric vehicle wireless power transfer (WPT) systems – Specific requirements for communication between electric road vehicle (EV) and infrastructure

Published By Publication Date Number of Pages
BSI 2020 90
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weโ€™re here to assist you 24/7.
Email:[email protected]

This Part of IEC 61980, which is a Technical Specification, applies to communication between electric road vehicle (EV) and wireless power transfer (WPT) systems when connected to the supply network, at standard supply voltages per IEC 60038 up to 1000 V AC and up to 1500 V DC.

This document also applies to wireless power transfer equipment supplied from on-site storage systems (e.g. buffer batteries) at standard supply voltages per IEC 60038 up to 1000 V AC and up to 1500 V DC.

The aspects covered in this document include

  • standards for operational characteristics and functional characteristics of the WPT communication subsystem,

  • communication requirements for WPT system while driving, which are under consideration,

  • communication requirements for two- and three-wheel vehicles, which are under consideration, and

  • communication requirements for bidirectional power transfer are under consideration

This document does not apply to

  • safety aspects related to maintenance, and

  • trolley buses, rail vehicles and vehicles designed primarily for use off-road.

PDF Catalog

PDF Pages PDF Title
2 undefined
7 CONTENTS
12 FOREWORD
14 INTRODUCTION
15 1 Scope
2 Normative references
16 3 Terms and definitions
19 4 Abbreviated terms
5 Communication of WPT systems
5.1 General
5.2 System architecture
20 Figures
Figure 1 โ€“ Possible elements of combination in a communication subsystem
21 5.3 General system requirements
5.3.1 General
5.3.2 Interoperability requirements
5.3.3 System configuration
Figure 2 โ€“ WPT site with a single supply device
22 5.3.4 Communication security
5.3.5 Timing
6 Power transfer process with respect to communication
6.1 General
6.2 Overview of operation process activities
Figure 3 โ€“ Operation process of activities for the WPT
23 6.3 Activities
6.3.1 Communication setup and service selection
6.3.2 Reject WPT session
6.3.3 Fine positioning
24 6.3.4 Pairing
6.3.5 Final compatibility check
25 6.3.6 Initial alignment check
6.3.7 Prepare power transfer
26 6.3.8 Time scheduled power transfer (informative)
27 6.3.9 Perform power transfer
28 6.3.10 Stop power transfer
29 6.3.11 WPT session
6.3.12 EV leaves WPT spot
6.3.13 Safety monitoring and diagnostics
30 6.3.14 Terminate communication
6.3.15 Terminate safety monitoring and diagnostics
6.3.16 Wake-up after power outage
31 7 Control process states
7.1 Supply device state definitions
7.1.1 Supply device state diagram
Figure 4 โ€“ Supply device state diagram
32 7.1.2 Stand by (WPT_S_SB)
7.1.3 Service initiated (WPT_S_SI)
Figure 5 โ€“ Activity communication setup
33 7.1.4 WPT session rejected
Figure 6 โ€“ Activity service selection
34 7.1.5 Awaiting alignment (WPT_S_AA)
Figure 7 โ€“ Activity reject WPT session
35 Figure 8 โ€“ Activity from fine positioning to initial alignment check
36 7.1.6 Idle (WPT_S_IDLE)
Figure 9 โ€“ Activity prepare power transfer
37 7.1.7 Power transfer (WPT_S_PT)
Figure 10 โ€“ Activity terminate WPT session
Figure 11 โ€“ Activity Sleep
38 7.1.8 Service terminated occupied (WPT_S_STO)
Figure 12 โ€“ Activity stop power transfer
39 7.1.9 Out of service (WPT_S_OOS)
7.1.10 Sleep mode WPT_S_SLP
Figure 13 โ€“ Activity EV leaves WPT spot
40 7.2 Supply device state transitions
Figure 14 โ€“ Activity wake-up
Tables
Table 1 โ€“ Supply device state transitions
41 7.3 EV device state definitions
7.3.1 EV device state diagram
42 7.3.2 Stand by (WPT_V_SB)
Figure 15 โ€“ EV device state diagram
43 7.3.3 Service initiated (WPT_V_SI)
Figure 16 โ€“ Activity communication setup (EV device state)
Figure 17 โ€“ Activity service selection (EV device state)
44 7.3.4 Awaiting alignment (WPT_V_AA)
Figure 18 โ€“ Activity from fine positioning to initial alignment check (EV device state)
45 7.3.5 Idle (WPT_V_IDLE)
7.3.6 Power transfer active (WPT_V_PT)
7.3.7 Off (WPT_V_OFF)
7.4 EV state transitions
Figure 19 โ€“ Activity prepare power transfer (EV device state)
46 7.5 Exception handling
7.5.1 General
7.5.2 Supply device exception handling (WPT_S_ERR)
7.5.3 EV device exception handling (WPT_V_ERR)
Table 2 โ€“ EV device state transitions
47 7.5.4 Exception descriptions
8 Communication parameter for WPT systems
8.1 General
8.2 General parameters
8.3 Communication setup
Table 3 โ€“ Exception handling
48 8.4 Service selection
Table 4 โ€“ Service selection EVCC request parameters
Table 5 โ€“ Service selection SECC response parameters
49 Table 6 โ€“ Method list for fine positioning
50 8.5 Fine positioning
8.5.1 General
8.5.2 Starting fine positioning
8.5.3 Fine positioning data exchange
Table 7 โ€“ Method list for pairing
Table 8 โ€“ Method list for initial alignment
Table 9 โ€“ Fine positioning response
51 8.5.4 Terminating fine positioning
8.6 Pairing
8.6.1 General
8.6.2 Start pairing
Table 10 โ€“ Pairing start request
Table 11 โ€“ Pairing start response
52 8.7 Initial alignment check
8.7.1 General
8.7.2 Initial alignment check request/response
Table 12 โ€“ Pairing confirmation request
Table 13 โ€“ Pairing confirmation response
Table 14 โ€“ Initial alignment check request
Table 15 โ€“ Initial alignment check response
53 8.8 Prepare power transfer
8.8.1 General
8.8.2 Final compatibility check
Table 16 โ€“ Final compatibility check request parameters
Table 17 โ€“ Final compatibility check response parameters
54 8.9 Perform power transfer
Table 18 โ€“ Perform power transfer request parameters
Table 19 โ€“ Perform power transfer response parameters
55 8.10 Stop power transfer
8.11 Terminate communication
8.12 Exception handling
Table 20 โ€“ Error request parameters
Table 21 โ€“ Error respond parameters
56 9 Message sequences of communication with WLAN
9.1 General
9.2 Messages of communication for power transfer
9.3 Communication setup
9.4 Service selection
57 9.5 Fine positioning
9.6 Pairing
9.7 Final compatibility check
9.8 Initial alignment check
58 9.9 Prepare power transfer
9.10 Perform power transfer
59 9.11 Stop power transfer
9.12 Terminate communication
60 Annex A (informative) Use cases
A.1 General
Figure A.1 โ€“ Use cases particularly for wireless power transfer
61 Figure A.2 โ€“ Use cases from ISO 15118-1 reusable for WPT systems
62 A.2 Use case descriptions
A.2.1 UC select supply device
Table A.1 โ€“ UC select supply device
63 Figure A.3 โ€“ Activity diagram for UC select supply device
64 A.2.2 UC service selection
Table A.2 โ€“ UC service selection
65 A.2.3 UC fine positioning
Table A.3 โ€“ UC fine positioning
66 Figure A.4 โ€“ Activity diagram for UC fine positioning
67 A.2.4 UC prepare power transfer
Table A.4 โ€“ UC prepare power transfer
68 Figure A.5 โ€“ Activity diagram for UC prepare power transfer
69 A.2.5 UC safety monitoring and diagnostics
A.2.6 UC perform power transfer
Table A.5 โ€“ UC safety monitoring and diagnostics
Table A.6 โ€“ UC perform power transfer
70 A.2.7 UC stop power transfer
Figure A.6 โ€“ Activity diagram for UC perform power transfer
Table A.7 โ€“ UC stop power transfer
71 Figure A.7 โ€“ Activity diagram for UC stop power transfer
72 A.2.8 UC sleep mode (optional)
Table A.8 โ€“ UC sleep mode
73 Figure A.8 โ€“ Activity diagram for UC sleep mode
74 Annex B (informative)Physical definition of links and signals
B.1 General
B.2 System architecture
B.3 WLAN
B.4 SR signal
75 B.5 LF signal (EV device to supply device)
76 Figure B.1 โ€“ Example arrangement of the auxiliary LF antennas for the primary device (left) and the vehicle (right)
77 B.6 Magnetic vector (EV device to supply device)
B.7 LPE (supply device to EV device)
Figure B.2 โ€“ Example arrangement of the auxiliary LF antennas for the primary device (left) and the EV (right)
78 Annex C (informative)Usage of supplemental signals
C.1 General
C.2 Fine positioning
C.2.1 General
C.2.2 Manual
C.2.3 Low power excitation (LPE)
79 C.2.4 LF signal
Table C.1 โ€“ Data of the antenna arrangement at EV to send to SECC
80 Table C.2 โ€“ Data of the antenna arrangement at primary device to send to EVCC
81 Figure C.1 โ€“ Explanation of parameters for LF fine positioning
Table C.3 โ€“ Data exchanged between EVCC and SECC during fine positioning
82 C.2.5 Magnetic vector
C.3 Pairing
C.3.1 General
C.3.2 Coding pattern specification
83 C.3.3 Low power excitation (LPE)
Figure C.2 โ€“ Coding pattern timing and examples
84 C.3.4 SR signal
C.3.5 LF signal
C.3.6 Magnetic vector
85 C.4 Initial alignment check
C.4.1 General
C.4.2 LPE target current check
86 C.4.3 RSSI method
Figure C.3 โ€“ Symmetrical antenna configuration for signal comparison with zero natural offset
87 C.5 Continuous alignment check
C.5.1 General
C.5.2 System anomaly check
Figure C.4 โ€“ Symmetrical antenna configuration for signal comparison with given natural offset
88 C.5.3 SR signal
C.6 Emergency shutdown
C.6.1 General
C.6.2 RF signal
C.6.3 Power termination
89 Bibliography