BSI PD CLC/TS 50625-3-1:2015
$142.49
Collection, logistics & treatment requirements for WEEE – Specification for de-pollution. General
Published By | Publication Date | Number of Pages |
BSI | 2015 | 32 |
This Technical Specification is intended to be used in conjunction with the WEEE Treatment Standard EN 50625‑1 for most types of WEEE (other documents will be developed to define requirements for specific WEEE requiring more specialised treatment).
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | Foreword |
8 | 1 Scope 2 Normative references 3 Terms and definitions |
9 | 4 De-pollution monitoring 4.1 Introduction 4.2 Target value methodology |
10 | 4.3 Mass Balance methodology 4.4 Analysis methodology |
12 | 5 Overview of the applicable methodologies — Applicable methodologies |
13 | 6 Large appliances 6.1 Introduction 6.2 Target value methodology 6.3 Analysis methodology |
14 | 7 Cooling and freezing appliances 7.1 Introduction 7.2 Target values methodology 7.3 Mass balance methodology 7.4 Analysis methodology |
15 | 8 CRT display /FPD appliances 8.1 Introduction 8.2 CRT display appliances – Target value methodology 8.3 CRT display appliances – Analysis methodology |
16 | 8.4 FPD appliances – Mass balance methodology 8.5 FPD appliances – Analysis methodology 9 Lamps — Introduction and analysis methodology 10 Small appliances 10.1 Introduction |
17 | 10.2 Target value methodology 10.3 Analysis methodology |
18 | 11 Protocol for components removed during a batch process 11.1 General procedure 11.2 Capacitors |
19 | 11.3 Batteries |
20 | Annex A (normative) Sampling protocol for the physically smallest non-metallic mechanical treatment fraction A.1 Introduction A.2 Sampling A.2.1 Identification of the physically smallest non-metallic mechanical treatment fraction A.2.2 Population A.2.3 Number of samples A.2.4 Size of samples |
21 | A.2.5 Principles of sampling A.2.5.1 Sampling during a treatment process A.2.5.2 Sampling after the treatment process |
22 | A.2.6 Mixed sample preparation A.2.7 Mixed sample reduction A.2.8 Sample sieving |
23 | A.2.9 Packaging of samples |
24 | Annex B (normative) Sampling protocol for plastics B.1 Introduction B.2 Sampling B.2.1 Population B.2.2 Number of samples B.2.3 Size of samples B.2.4 Principle of sampling B.2.4.1 Sampling during a treatment process |
25 | B.2.4.2 Sampling after the treatment process |
26 | B.2.5 Mixed sample preparation B.2.6 Mixed sample reduction B.2.7 Packaging and sending of samples |
27 | Annex C (normative) Targets |
28 | Annex D (informative) Target calculation example — Calculation example for large appliance |