Shopping Cart

No products in the cart.

IEEE P741:2022 Edition

$44.96

IEEE Draft Standard for Criteria for the Protection of Class 1E Power Systems and Equipment in Nuclear Power Generating Stations

Published By Publication Date Number of Pages
IEEE 2022 67
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

Revision Standard – Active – Draft. Criteria that establish protection requirements for Class 1E power systems and equipment are prescribed in this standard. The purpose of and the means for obtaining protection from electrical and mechanical damage, or failures that can occur within a time period that is shorter than that required for operator action, are described. Testing and surveillance requirements are included. Plant physical design requirements to protect against events such as pipe whip, fire, dropped load, etc., are not included.

PDF Catalog

PDF Pages PDF Title
1 IEEE Std 741ā„¢-2022 Front cover
2 Title page
4 Important Notices and Disclaimers Concerning IEEE Standards Documents
8 Participants
10 Introduction
11 Contents
12 1.ā€‚Overview
1.1ā€‚Scope
1.2ā€‚Word usage
2.ā€‚Normative references
14 3.ā€‚Definitions, acronyms, and abbreviations
3.1ā€‚Definitions
15 3.2ā€‚Acronyms and abbreviations
16 4.ā€‚General design criteria
4.1ā€‚Criteria
17 5.ā€‚Principal design criteria and requirements
5.1ā€‚AC power distribution systems
19 5.2ā€‚DC power system
5.3ā€‚Instrumentation and control power system
5.4ā€‚Primary containment electrical penetration assemblies
20 5.5ā€‚Valve actuator motors (direct gear driven)
21 6.ā€‚Testing and surveillance
6.1ā€‚Device testing
6.2ā€‚Preoperational tests
6.3ā€‚Surveillance
23 AnnexĀ A (normative) Illustration of concepts associated with degraded voltage protection
A.1ā€‚Purpose
A.2ā€‚Discussion
26 A.3ā€‚Degraded voltage relay settings
27 A.4ā€‚Degraded voltage relay analysis
32 A.5ā€‚Loss of voltage relay settings
A.6ā€‚High-voltage conditions
A.7ā€‚Off-site system voltage considerations
33 A.8ā€‚Tolerances
A.9ā€‚Summary
34 AnnexĀ B (informative) Guidelines for selection of overload protection for valve actuator motor (VAM) circuits
B.1ā€‚Purpose
B.2ā€‚Discussion
B.3ā€‚Overload protection devices
37 B.4ā€‚Typical procedures for selection of TORs
55 AnnexĀ C (informative) Auxiliary system automatic bus transferā€”protection concerns
C.1ā€‚Purpose
C.2ā€‚Discussion
57 C.3ā€‚Bus transfer analysis
59 C.4ā€‚Bus transfer protection issues
60 C.5ā€‚Implementation of a bus transfer scheme using dynamic modeling
62 AnnexĀ D (informative) Use of high-speed magnetic circuit breakers for special applications
D.1ā€‚Purpose
D.2ā€‚Discussion
65 AnnexĀ E (informative) Bibliography
67 Back cover
IEEE P741
$44.96