{"id":135917,"date":"2024-10-19T07:50:04","date_gmt":"2024-10-19T07:50:04","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/or-energycode-2014\/"},"modified":"2024-10-25T00:00:25","modified_gmt":"2024-10-25T00:00:25","slug":"or-energycode-2014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/or\/or-energycode-2014\/","title":{"rendered":"OR EnergyCode 2014"},"content":{"rendered":"

This is a fully integrated custom code based on the 2009 International Energy Conservation Code\u00c2\u00ae. The 2014 Oregon Energy Efficiency Specialty Code is also referred to as Chapter 13 of the 2014 Oregon Structural Specialty Code. Effective date: July 1, 2014.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\n2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE BASED ON THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE\u00ae <\/td>\n<\/tr>\n
2<\/td>\nCOPYRIGHT <\/td>\n<\/tr>\n
3<\/td>\nPREFACE <\/td>\n<\/tr>\n
5<\/td>\nEFFECTIVE USE OF THE INTERNATIONAL ENERGY CONSERVATION CODE <\/td>\n<\/tr>\n
7<\/td>\nORDINANCE <\/td>\n<\/tr>\n
9<\/td>\nTABLE OF CONTENTS <\/td>\n<\/tr>\n
11<\/td>\nCHAPTER 1 ADMINISTRATION
PART 1\u2014SCOPE AND APPLICATION
SECTION 101 SCOPE AND GENERAL REQUIREMENTS <\/td>\n<\/tr>\n
12<\/td>\nSECTION 102 ALTERNATE MATERIALS\u2014METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS
PART 2\u2014ADMINISTRATION AND ENFORCEMENT
SECTION 103 CONSTRUCTION DOCUMENTS
SECTION 104 INSPECTIONS
SECTION 105 VALIDITY
SECTION 106 REFERENCED STANDARDS
SECTION 107 FEES
SECTION 108 STOP WORK ORDER
SECTION 109 BOARD OF APPEALS <\/td>\n<\/tr>\n
13<\/td>\nCHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n
17<\/td>\nCHAPTER 3 CLIMATE ZONES
SECTION 301 CLIMATE ZONES
TABLE 301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY COUNTY
SECTION 302 DESIGN CONDITIONS
SECTION 303 MATERIALS, SYSTEMS AND EQUIPMENT <\/td>\n<\/tr>\n
18<\/td>\nFIGURE 301.1 CLIMATE ZONES <\/td>\n<\/tr>\n
21<\/td>\nCHAPTER 4 RESIDENTIAL ENERGY
PART I\u2014ENERGY CONSERVATION
SECTION 401 SCOPE <\/td>\n<\/tr>\n
23<\/td>\nCHAPTER 5 COMMERCIAL ENERGY EFFICIENCY
SECTION 501 GENERAL
SECTION 502 BUILDING ENVELOPE REQUIREMENTS
TABLE 502.1.1 BUILDING ENVELOPE REQUIREMENTS – OPAQUE ASSEMBLIES <\/td>\n<\/tr>\n
24<\/td>\nTABLE 502.1.2 BUILDING ENVELOPE REQUIREMENTS OPAQUE ELEMENT, MAXIMUM U-FACTORS <\/td>\n<\/tr>\n
25<\/td>\nTABLE 502.2(2) METAL BUILDING ASSEMBLY DESCRIPTIONSa
TABLE 502.3 BUILDING ENVELOPE REQUIREMENTS: FENESTRATION <\/td>\n<\/tr>\n
27<\/td>\nTABLE 502.4.3 MAXIMUM AIR INFILTRATION RATEF OR FENESTRATION ASSEMBLIES
SECTION 503 BUILDING MECHANICAL SYSTEMS <\/td>\n<\/tr>\n
28<\/td>\nEQUATION 5-1
EQUATION 5-2 <\/td>\n<\/tr>\n
29<\/td>\nTABLE 503.2.3(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS <\/td>\n<\/tr>\n
30<\/td>\nTABLE 503.2.3(1)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS <\/td>\n<\/tr>\n
31<\/td>\nTABLE 503.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS <\/td>\n<\/tr>\n
32<\/td>\nTABLE 503.2.3(2)\u2014continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS <\/td>\n<\/tr>\n
33<\/td>\nTABLE 503.2.3(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS <\/td>\n<\/tr>\n
34<\/td>\nTABLE 503.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES\/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS <\/td>\n<\/tr>\n
35<\/td>\nTABLE 503.2.3(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS
TABLE 503.2.3(6) CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS <\/td>\n<\/tr>\n
36<\/td>\nTABLE 503.2.3(7) WATER CHILLING PACAKAGES \u2013 EFFICIENCY REQUIREMENTSa, b, c <\/td>\n<\/tr>\n
37<\/td>\nTABLE 503.2.3(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT <\/td>\n<\/tr>\n
38<\/td>\nTABLE 503.2.3(9) MINIMUM EFFICIENCY AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS <\/td>\n<\/tr>\n
39<\/td>\nTABLE 503.2.3(10) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED VARIABLE REFRIGERANT FLOW AIR-TO-AIR AND APPLIED HEAT PUMP <\/td>\n<\/tr>\n
41<\/td>\nEQUATION 5-3 <\/td>\n<\/tr>\n
42<\/td>\nTABLE 503.2.8 MINIMUM PIPE INSULATION THICKNESS (thickness in inches)a, b, c <\/td>\n<\/tr>\n
43<\/td>\nTABLE 503.2.10.1(1) FAN POWER LIMITATION <\/td>\n<\/tr>\n
44<\/td>\nTABLE 503.2.10.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
TABLE 503.2.12 MAXIMUM HOT GAS BYPASS CAPACITY <\/td>\n<\/tr>\n
48<\/td>\nSECTION 504 SERVICE WATER HEATING <\/td>\n<\/tr>\n
49<\/td>\nTABLE 504.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT <\/td>\n<\/tr>\n
50<\/td>\nSECTION 505 ELECTRICAL POWER AND LIGHTING SYSTEMS (MANDATORY) <\/td>\n<\/tr>\n
52<\/td>\nTABLE 505.5.2(a) INTERIOR LIGHTING POWER ALLOWANCES <\/td>\n<\/tr>\n
53<\/td>\nTABLE 505.5.2(b) SPACE-BY-SPACE METHOD MAXIMUM ALLOWABLE LIGHTING POWER DENSITY (LPD)
TABLE 505.5.2(b)\u2014continued SPACE-BY-SPACE METHOD MAXIMUM ALLOWABLE LIGHTING POWER DENSITY (LPD) <\/td>\n<\/tr>\n
54<\/td>\nSECTION 506 WHOLE BUILDING APPROACH <\/td>\n<\/tr>\n
55<\/td>\nTABLE 505.6.2(1) EXTERIOR LIGHTING ZONES
TABLE 505.6.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS <\/td>\n<\/tr>\n
56<\/td>\nSECTION 507 OTHER EQUIPMENT
TABLE 507.1 NEMA CLASS 1 EFFICIENCY LEVELS FOR LIQUID-FILLED DISTRIBUTION TRANSFORMERS1 <\/td>\n<\/tr>\n
57<\/td>\nTABLE 507.2 NEMA CLASS 1 EFFICIENCY LEVELS FOR DRY-TYPE DISTRIBUTION TRANSFORMERS1 <\/td>\n<\/tr>\n
59<\/td>\nCHAPTER 6 REFERENCED STANDARDS
AAMA
AHRI
AMCA
ANSI <\/td>\n<\/tr>\n
60<\/td>\nASHRAE
ASTM
CSA
DOE
IESNA <\/td>\n<\/tr>\n
61<\/td>\nISO
NFRC
SMACNA
UL
US\u2014FTC
WDMA <\/td>\n<\/tr>\n
63<\/td>\nINDEX <\/td>\n<\/tr>\n
69<\/td>\nIECC TOOLS <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Oregon Energy Efficiency Specialty Code<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
OR<\/b><\/a><\/td>\n2014<\/td>\n70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":135918,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2730],"product_tag":[],"class_list":{"0":"post-135917","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-or","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/135917","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/135918"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=135917"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=135917"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=135917"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}