{"id":226170,"date":"2024-10-19T14:41:56","date_gmt":"2024-10-19T14:41:56","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-609682015\/"},"modified":"2024-10-25T08:36:41","modified_gmt":"2024-10-25T08:36:41","slug":"bs-en-609682015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-609682015\/","title":{"rendered":"BS EN 60968:2015"},"content":{"rendered":"
This International Standard specifies the safety and interchangeability requirements, together with the test methods and conditions required to show compliance of tubular fluorescent lamps with integrated means for controlling starting and stable operation (self-ballasted fluorescent lamps).<\/p>\n
These lamps are intended for domestic and similar general lighting purposes, having a rated voltage of 50 V to 250 V, having a rated frequency of 50 Hz or 60Hz and having IEC 60061\u20111<\/span> <\/span> compliant caps.<\/p>\n For a cap-holder system not specifically mentioned in this standard, the relevant information on safety related tests provided by the manufacturer will apply.<\/p>\n The requirements of this standard relate only to type testing.<\/p>\n Recommendations for whole product testing or batch testing are given in Annex A<\/span>.<\/p>\n This part of the standard covers photobiological safety according to IEC 62471<\/span> <\/span> and IEC TR 62471\u20112<\/span> <\/span>. Blue light and infrared hazards are below the level which requires marking.<\/p>\n Self-ballasted fluorescent lamps for general lighting services. Safety requirements<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 6<\/td>\n English
\n
CONTENTS <\/td>\n<\/tr>\n\n 8<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 10<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 11<\/td>\n 3 Terms and definitions <\/td>\n<\/tr>\n \n 12<\/td>\n 4 General requirements and general test requirements
5 Marking
5.1 Lamp marking
5.2 Additional marking <\/td>\n<\/tr>\n\n 13<\/td>\n 5.3 Compliance of marking
Figures
\n
Figure 1 \u2013 Dimming not allowed
Figure 2 \u2013 Lamp to be used in dry conditions or in a luminaire that provides protection <\/td>\n<\/tr>\n\n 14<\/td>\n 5.4 Locations where marking is required (See Table 1)
6 Interchangeability, mass and bending moment
6.1 Interchangeability
6.2 Bending moment and mass imparted by the lamp at the lampholder
Tables
\n
Table 1 \u2013 Locations where marking is required <\/td>\n<\/tr>\n\n 15<\/td>\n Figure 3 \u2013 Sample test arrangement for bending moment impartedby the lamp at the lampholder
Table 2 \u2013 Bending moments and masses <\/td>\n<\/tr>\n\n 16<\/td>\n 7 Protection against electric shock
Figure 4 \u2013 Standard test finger (according to IEC\u00a060529) <\/td>\n<\/tr>\n\n 17<\/td>\n 8 Insulation resistance and electric strength
8.1 General
8.2 Insulation resistance
8.3 Electric strength
9 Mechanical strength
9.1 General <\/td>\n<\/tr>\n\n 18<\/td>\n 9.2 Torsion resistance
9.2.1 Torsion resistance of unused lamps <\/td>\n<\/tr>\n\n 19<\/td>\n Figure 5 \u2013 Holder for torsion test on lamps with screw caps
Figure 6 \u2013 Holder for torsion test on lamps with bayonet caps <\/td>\n<\/tr>\n\n 20<\/td>\n 9.2.2 Torsion resistance of lamps after a defined time of usage
9.3 Axial strength of Edison caps
Table 3 \u2013 Torsion test values for unused lamps <\/td>\n<\/tr>\n\n 21<\/td>\n 10 Cap temperature rise
Figure 7 \u2013 Test equipment for applying an axial force
Table 4 \u2013 Values for axial force <\/td>\n<\/tr>\n\n 22<\/td>\n 11 Resistance to heat
Figure 8 \u2013 Ball-pressure apparatus
Table 5 \u2013 Maximum cap temperature rise <\/td>\n<\/tr>\n\n 23<\/td>\n 12 Resistance to flame and ignition <\/td>\n<\/tr>\n \n 24<\/td>\n 13 Fault conditions
13.1 General requirements
13.2 Test conditions <\/td>\n<\/tr>\n\n 25<\/td>\n 13.3 Test setup for non-starting lamp
14 Creepage distances and clearances
15 Lamp end of life
15.1 General requirements
15.2 Test setup
Figure 9 \u2013 Schematic diagram for non-starting lamp test <\/td>\n<\/tr>\n\n 26<\/td>\n 15.3 Compliance
16 Photobiological safety
16.1 UV radiation
16.2 Other photobiological effects
17 Abnormal operation <\/td>\n<\/tr>\n\n 27<\/td>\n 18 Test conditions for dimmable and three-way lamps
Figure 10 \u2013 Test circuit for testing a non-dimmable lampat a dimmer or electronic switch <\/td>\n<\/tr>\n\n 28<\/td>\n 19 Whole production assessment
20 Collation of type test verification
Table 6 \u2013 Sampling sizes for type test <\/td>\n<\/tr>\n\n 29<\/td>\n 21 Information for luminaire design <\/td>\n<\/tr>\n \n 30<\/td>\n Annex A (informative) Whole production assessment
A.1 Assessment \u2013 General
A.2 Whole production assessment by means of the manufacturer\u2019s records
Table A.1 \u2013 Production assessment <\/td>\n<\/tr>\n\n 32<\/td>\n Annex B (informative) Information for luminaire design
B.1 Water contact <\/td>\n<\/tr>\n\n 33<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2015<\/td>\n 36<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":226173,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[523,2641],"product_tag":[],"class_list":{"0":"post-226170","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-140-30","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/226170","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/226173"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=226170"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=226170"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=226170"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}