{"id":236504,"date":"2024-10-19T15:26:15","date_gmt":"2024-10-19T15:26:15","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60130-92011\/"},"modified":"2024-10-25T10:03:24","modified_gmt":"2024-10-25T10:03:24","slug":"bs-en-60130-92011","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60130-92011\/","title":{"rendered":"BS EN 60130-9:2011"},"content":{"rendered":"
IEC 60139-9:2011 relates to circular connectors for radio and associated sound equipment. This fourth edition cancels and replaces the third edition of IEC 60130-9, published in 2000, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – the scope has been amended to clarify its separation through its field of application, from IEC 61076-2-106; – 8-pole connector styles 60130-9 IEC-22 through 60130-9 IEC-25 with screw locking have been deleted as obsolete and overlapping with some styles of IEC 61076-2-106; – application and connections in Table 1 have been deleted because of referencing obsolete sound equipment. Titles of the dimension sheets and the clause headlines of Annex A have been amended accordingly; – the reference to safety requirements according to IEC 60065 has been deleted.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
7<\/td>\n | English \n CONTENTS <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 3 Technical information 3.1 IEC type designation <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Tables \n Table 1 \u2013 Type designation <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 3.2 Contact arrangements and connections 4 Dimensional information <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Figures \n Figure 1 \u2013 Free connector 60130-9 IEC-01 Table 2 \u2013 Free connector 60130-9 IEC-01 <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Figure 2 \u2013 Fixed connector 60130-9 IEC-02 Table 3 \u2013 Fixed connector 60130-9 IEC-02 <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Figure 3 \u2013 Free connector 60130-9 IEC-03 Table 4 \u2013 Free connector 60130-9 IEC-03 <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Figure 4 \u2013 Fixed connector 60130-9 IEC-04 Table 5 \u2013 Fixed connector 60130-9 IEC-04 <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Figure 5 \u2013 Free connector 60130-9 IEC-05 Table 6 \u2013 Free connector 60130-9 IEC-05 <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Figure 6 \u2013 Fixed connector 60130-9 IEC-06 Table 7 \u2013 Fixed connector 60130-9 IEC-06 <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Figure 7 \u2013 Fixed connector 60130-9 IEC-07 Table 8 \u2013 Fixed connector 60130-9 IEC-07 <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Figure 8 \u2013 Fixed connector 60130-9 IEC-08 Table 9 \u2013 Fixed connector 60130-9 IEC-08 <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Figure 9 \u2013 Free connector 60130-9 IEC-09 Table 10 \u2013 Free connector 60130-9 IEC-09 <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Figure 10 \u2013 Free connector 60130-9 IEC-10 Table 11\u2013 Free connector 60130-9 IEC-10 <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Figure 11 \u2013 Fixed connector 60130-9 IEC-11 Table 12 \u2013 Fixed connector 60130-9 IEC-11 <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Figure 12 \u2013 Free connector 60130-9 IEC-12 Table 13 \u2013 Free connector 60130-9 IEC-12 <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Figure 13 \u2013 Fixed connector 60130-9 IEC-13 Table 14 \u2013 Fixed connector 60130-9 IEC-13 <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Figure 14 \u2013 Free connector 60130-9 IEC-14 Table 15 \u2013 Free connector 60130-9 IEC-14 <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Figure 15 \u2013 Fixed connector 60130-9 IEC-15 Table 16 \u2013 Fixed connector 60130-9 IEC-15 <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Figure 16 \u2013 Fixed connector 60130-9 IEC-15a Table 17 \u2013 Fixed connector 60130-9 IEC-15a <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Figure 17\u2013 Free connector 60130-9 IEC-16 Table 18\u2013 Free connector 60130-9 IEC-16 <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Figure 18 \u2013 Fixed connector 60130-9 IEC-17 Table 19 \u2013 Fixed connector 60130-9 IEC-17 <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Figure 19 \u2013 Free connector 60130-9 IEC-18 Table 20 \u2013 Free connector 60130-9 IEC-18 <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Figure 20 \u2013 Fixed connector 60130-9 IEC-19 Table 21 \u2013 Fixed connector 60130-9 IEC-19 <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Figure 21 \u2013 Free connector 60130-9 IEC-20 Table 22 \u2013 Free connector 60130-9 IEC-20 <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Figure 22 \u2013 Fixed connector 60130-9 IEC-21 Table 23 \u2013 Fixed connector 60130-9 IEC-21 <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Figure 23 \u2013 Fixed connector 60130-9 IEC-26 Table 24 \u2013 Fixed connector 60130-9 IEC-26 <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | Figure 24 \u2013 Free connector 60130-9 IEC-27 Table 25 \u2013 Free connector 60130-9 IEC-27 <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Figure 25 \u2013 Free connector 60130-9 IEC-28 Table 26 \u2013 Free connector 60130-9 IEC-28 <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | Figure 26 \u2013 Fixed connector 60130-9 IEC-29 Table 27 \u2013 Fixed connector 60130-9 IEC-29 <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | Figure 27 \u2013 Fixed connector 60130-9 IEC-30 Table 28 \u2013 Fixed connector 60130-9 IEC-30 <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | Figure 28 \u2013 Free connector 60130-9 IEC-31 Table 29 \u2013 Free connector 60130-9 IEC-31 <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 5 Gauges 5.1 Gauges for checking dimensions Figure 29 \u2013 Gauge for connector types 60130-9 IEC-02, 04, 07, 08, 09, 11, 13, 15, 17, 18, 21 Figure 30 \u2013 Gauge for connector types60130-9 IEC-07, 08 and 09 Table 30 \u2013 Dimensions of gauges for checking dimensions <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 5.2 Gauges for measuring contact resistance 5.3 Gauges for measuring retention force Figure 31 \u2013 Gauge for connectortypes 60130-9 IEC-02, 04, 07, 08, 09, 11, 13, 15, 17, 18, 21 Figure 32 \u2013 Gauge for connector types 60130-9 IEC-07, 08 and 09 Table 31 \u2013 Dimensions of gauges for measuring retention force <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 5.4 Gauge for voltage proof and insulation resistance testsof connectors 60130-9 IEC-08 Figure 33 \u2013 Gauge for voltage proof and insulation resistance testsof connectors 60130-9 IEC-08 Table 32 \u2013 Dimensions of gauge for voltage proof and insulation resistance tests of connectors 60130-9 IEC-08 <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 5.5 Gauge for voltage proof and contact resistance tests of connectors 60130-9 IEC-08 Figure 34 \u2013 Gauge for voltage proof and contact resistance testsof connectors 60130-9 IEC-08 Table 33 \u2013 Dimensions of gauge for voltage proof and contact resistance tests of connectors 601309 IEC08 <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 6 Characteristics 6.1 Rated values 6.2 Climatic category 7 Schedule for type tests Table 34 \u2013 Climatic category Table 35 \u2013 Test group for all specimens <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | Table 36 \u2013 Test group for the first lot <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Table 37 \u2013 Test group for the second and third lot <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | Table 38 \u2013 Test group for the fourth lot Table 39 \u2013 Test group for switches in 60130-9 IEC-08 <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Annex A (normative) \nDescription of the connectors <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Annex B (normative) \nMeasurement of individual contacts (resilient contacts only) <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Annex C (informative) \nExamples of circuitry of connector with switch Figure C.1 \u2013 Free connector 60130-9 IEC-05 inserted in position A Figure C.2 \u2013 Free connector 60130-9 IEC-05 inserted in position B <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Connectors for frequencies below 3 MHz – Circular connectors for radio and associated sound equipment<\/b><\/p>\n |