{"id":252839,"date":"2024-10-19T16:41:53","date_gmt":"2024-10-19T16:41:53","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-62056-7-32017\/"},"modified":"2024-10-25T12:02:02","modified_gmt":"2024-10-25T12:02:02","slug":"bs-en-62056-7-32017","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-62056-7-32017\/","title":{"rendered":"BS EN 62056-7-3:2017"},"content":{"rendered":"
This International Standard specifies DLMS\/COSEM wired and wireless M-Bus communication profiles for local and neighbourhood networks.<\/p>\n
Setting up and managing the M-Bus communication channels of M-Bus devices, the M-Bus network, registering slave devices and \u2013 when required \u2013 repeaters is out of the scope of this International Standard.<\/p>\n
The scope of this communication profile standard is restricted to aspects concerning the use of communication protocols in conjunction with the COSEM data model and the DLMS\/COSEM application layer. Data structures specific to a communication protocol are out of the scope of this standard. Any project-specific definitions of data structures and data contents may be provided in project-specific companion specifications.<\/p>\n
Annex A (informative) provides information on M-Bus frame structures, addressing schemes and an encoding example.<\/p>\n
Annex B (normative) points to COSEM interface classes to set up and manage the wired and wireless M-Bus communication channel.<\/p>\n
Annex C (informative) provides MSCs for representative instances of communication.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 3 Terms, definitions and abbreviated terms 3.1 Terms and definitions 3.2 Abbreviated terms <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4 Targeted communication environments 5 Use of the communication layers for this profile 5.1 Information related to the use of the standard specifying the lower layers 5.2 Structure of the communication profiles Figures Figure 1 \u2013 Entities and interfaces of a smart metering system using the terminology of IEC\u00a062056-1-0 <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.3 Lower protocol layers and their use 5.3.1 Physical layer 5.3.2 Link layer Figure 2 \u2013 The DLMS\/COSEM wired and wireless M-Bus communication profiles <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.3.3 Transport layer 5.4 Service mapping and adaptation layers 5.4.1 Overview <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.4.2 MBUS-DATA service primitives Figure 3 \u2013 Summary of DLMS\/COSEM M-Bus-based TL services <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.4.3 MBUS-DATA protocol specification <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.5 Registration and connection management 6 Identification and addressing scheme 6.1 Overview <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 6.2 Link Layer Address for wired M-Bus Figure 4 \u2013 Identification and addressing scheme in the wired M-Bus profile <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 6.3 Link Layer Address for wireless M-Bus 6.4 Link Layer Address for M-Bus broadcast Figure 5 \u2013 Link Layer Address for wireless M-Bus Tables Table 1 \u2013 Wired M-Bus Link Layer Addresses <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 6.5 Transport layer address Table 2 \u2013 DLMS\/COSEM M-Bus-based TL CITL values <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Figure 6 \u2013 M-Bus TPDU formats Figure 7 \u2013 CITL without M-Bus data header <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 6.6 Application addressing extension \u2013 M-Bus wrapper Table 3 \u2013 CI fields used for link management purposes Table 4 \u2013 Client and server SAPs <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 7 Specific considerations and constraints for using certain services within profile 7.1 Overview 7.2 Application association establishment and release: ACSE services Table 5 \u2013 Application associations and data exchange in the M-Bus-based profiles <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 7.3 xDLMS services 7.3.1 Request \u2013 response type services 7.3.2 Unsolicited services 7.3.3 Broadcast messages <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 7.4 Security mechanisms 7.5 Transporting long application messages 7.6 Media access, bandwidth and timing considerations 8 Communication configuration and management <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Annex\u00a0A (informative)M-Bus frame structures, addressing schemes and examples A.1 General Figure A.1 \u2013 M-Bus communication paths direct or cascaded <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | A.2 None, short or long M-Bus data header <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Figure A.2 \u2013 Wired M-Bus frame structure, none M-Bus data header Figure A.3 \u2013 Wired M-Bus frame structure with long M-Bus data header <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Figure A.4 \u2013 Wireless M-Bus frame structure with short ELL, no M-Bus data header Figure A.5 \u2013 Wireless M-Bus frame structure with long ELL, no M-Bus data header <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | A.3 Encoding example: Data-Notification carrying daily billing data Figure A.6 \u2013 Wireless M-Bus frame structure with long ELL and long M-Bus data header <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Table A.1 \u2013 Example: Daily billing data <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | Figure A.7 \u2013 Daily billing data without \/ with DLMS\/COSEM security applied <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | Annex\u00a0B (normative) New COSEM interface classes related to the M-Bus communication profiles <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Annex\u00a0C (informative)Message sequence charts <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Electricity metering data exchange. The DLMS\/COSEM suite – Wired and wireless M-Bus communication profiles for local and neighbourhood networks<\/b><\/p>\n |