{"id":29300,"date":"2024-10-17T03:14:06","date_gmt":"2024-10-17T03:14:06","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d1676\/"},"modified":"2024-10-24T14:09:55","modified_gmt":"2024-10-24T14:09:55","slug":"astm-d1676","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d1676\/","title":{"rendered":"ASTM-D1676"},"content":{"rendered":"<\/p>\n

1.1 These test methods cover procedures for testing film-insulated magnet wire that is used in electrical apparatus. These test methods are intended primarily for the evaluation of the electrical insulating materials used. The intent is that these test methods be used, except where modified, by individual specifications for particular applications.<\/p>\n

1.2 These test methods present different procedures for evaluating given properties of round, rectangular or square, copper or aluminum film-insulated magnet wire.<\/p>\n

1.3 The values stated in inch-pound units are the standard. The SI units in parentheses are provided for information only.<\/p>\n

1.4 The test methods appear in the following sections:<\/p>\n

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in 9.5, 19.1, 19.3, 19.8, 52.1, 58, 59.1, 74.1, 112.1, 135.4, and 182.3.<\/span><\/span><\/p>\n

Note<\/span> 1This test method is related to IEC 60851. Since both methods contain multiple test procedures, many procedures are technically equivalent while others differ significantly.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents <\/td>\n<\/tr>\n
2<\/td>\nTerminology
Scope
Terminology
Summary of Test Method
Significance and Use
Apparatus
TABLE 1 <\/td>\n<\/tr>\n
3<\/td>\nTest Specimen Preparation
Procedure
Report
Precision and Bias
Scope
TABLE 2 <\/td>\n<\/tr>\n
4<\/td>\nTerminology
Summary of Test Method
Significance and Use
Apparatus
Test Specimen Preparation
FIG. 1 <\/td>\n<\/tr>\n
5<\/td>\nProcedure
FIG. 2 <\/td>\n<\/tr>\n
6<\/td>\nReport
Precision and Bias
Scope
Significance and Use
Apparatus
TABLE 3
FIG. 3 <\/td>\n<\/tr>\n
7<\/td>\nTest Specimen Preparation
Procedure
Report
Precision and Bias
Scope
Terminology
Summary of Test Method
Significance and Use
Apparatus
FIG. 4 <\/td>\n<\/tr>\n
8<\/td>\nTest Specimen
Procedure
FIG. 5
FIG. 6
TABLE 4 <\/td>\n<\/tr>\n
9<\/td>\nCalculation
Report
Precision and Bias
Scope
Terminology
Significance and Use
Apparatus
TABLE 5
TABLE 6 <\/td>\n<\/tr>\n
10<\/td>\nTest Specimen
Procedure
Report
FIG. 7
FIG. 8 <\/td>\n<\/tr>\n
11<\/td>\nPrecision and Bias
Scope
Terminology
Significance and Use
Apparatus
Test Specimen
Procedure
Report
Precision and Bias
TABLE 7 <\/td>\n<\/tr>\n
12<\/td>\nScope
Significance and Use
Reagents and Materials
Test Specimen
Procedure
Report
Precision and Bias
Scope
Terminology
Significance and Use
Apparatus
Test Specimen
Procedure <\/td>\n<\/tr>\n
13<\/td>\nReport
Precision and Bias
Scope
Apparatus
Test Specimen
Conditioning
Procedure
TABLE 8 <\/td>\n<\/tr>\n
14<\/td>\nReport
Precision and Bias
Scope
Apparatus
TABLE 9
FIG. 9 <\/td>\n<\/tr>\n
15<\/td>\nTest Specimen
Conditioning
Procedure
Report
Precision and Bias
Scope
Significance and Use
Apparatus
Test Specimen
Procedure
TABLE 10 <\/td>\n<\/tr>\n
16<\/td>\nReport
Precision and Bias
Scope
Summary of Test Method
Significance and Use
Apparatus
Reagent
Test Specimen
Procedure
Report
Precision and Bias
TABLE 11 <\/td>\n<\/tr>\n
17<\/td>\nScope
Significance and Use
Apparatus
Test Specimen
Procedure <\/td>\n<\/tr>\n
18<\/td>\nReport
Precision and Bias
Scope
Terminology
Significance and Use
Apparatus
TABLE 12 <\/td>\n<\/tr>\n
19<\/td>\nTest Specimen
Procedure
Report
Precision and Bias
Scope <\/td>\n<\/tr>\n
20<\/td>\nSignificance and Use
Apparatus
Test Specimen
Procedure
Report
Precision and Bias
Scope
Significance and Use
Apparatus
Test Specimen
Procedure
Calculation
Report <\/td>\n<\/tr>\n
21<\/td>\nPrecision and Bias
Scope
Terminology
Summary of Test Method
Significance and Use
Apparatus
TABLE 13
FIG. 10 <\/td>\n<\/tr>\n
22<\/td>\nReagents
Test Specimen Preparation
Procedure <\/td>\n<\/tr>\n
23<\/td>\nCalculation
Report
Precision and Bias
Scope
Terminology
Significance and Use
Apparatus
Procedure (Round Wire, 4 AWG and Finer)
TABLE 14 <\/td>\n<\/tr>\n
24<\/td>\nProcedure (Rectangular, Square, and Round Wire Larger Than 4 AWG)
Report
Precision and Bias
Scope
Terminology
Significance and Use
Elastic Ratio Method <\/td>\n<\/tr>\n
25<\/td>\nLow Stress Elongation (LSE)
Springback Test (AWG 14-30) <\/td>\n<\/tr>\n
26<\/td>\nTABLE 15
FIG. 11
FIG. 12 <\/td>\n<\/tr>\n
27<\/td>\nSpringback Test for Rectangular, Square and Round Wire Larger than AWG 14 Film-Insulated Magnet Wires
FIG. 13
TABLE 16
FIG. 14 <\/td>\n<\/tr>\n
28<\/td>\nScope
Terminology
Significance and Use
Apparatus
Test Specimen
Report
Precision and Bias
Scope
Significance and Use <\/td>\n<\/tr>\n
29<\/td>\nApparatus
Test Specimen
Procedure
Report
Precision and Bias
FIG. 15
TABLE 17 <\/td>\n<\/tr>\n
30<\/td>\nScope
Terminology
Significance and Use
Apparatus
Test Specimen Preparation
Procedure
Report
Precision and Bias
Scope
Terminology
Significance and Use <\/td>\n<\/tr>\n
31<\/td>\nApparatus
Procedure
Evaluation
Report
Precision and Bias
Scope
Significance and Use
FIG. 16 <\/td>\n<\/tr>\n
32<\/td>\nApparatus
Reagents and Materials
Components
Transformer Oil Conditioning
Round Wire Smaller Than 9 AWG, Test Specimens
Round Wire Larger than 10 AWG, Rectangular and Square Wire Test Specimens
Procedure
TABLE 18 <\/td>\n<\/tr>\n
33<\/td>\nReport
TABLE 19
Precision and Bias
Keywords <\/td>\n<\/tr>\n
34<\/td>\nX1. SIPHON CUP
X1.1
X1.2
X1.3 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

D1676-03(2011) Standard Test Methods for Film-Insulated Magnet Wire<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2011<\/td>\n34<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":29301,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[492,2637],"product_tag":[],"class_list":{"0":"post-29300","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-060-10","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/29300","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/29301"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=29300"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=29300"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=29300"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}