{"id":294238,"date":"2024-10-19T20:00:07","date_gmt":"2024-10-19T20:00:07","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-67442016-tc\/"},"modified":"2024-10-25T17:13:27","modified_gmt":"2024-10-25T17:13:27","slug":"bs-67442016-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-67442016-tc\/","title":{"rendered":"BS 6744:2016 – TC"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\ncompares BS 6744:2016 <\/td>\n<\/tr>\n
2<\/td>\nTRACKED CHANGES
Text example 1 \u2014 indicates added text (in green) <\/td>\n<\/tr>\n
4<\/td>\nPublishing and copyright information
Publication history
Amendments issued since publication <\/td>\n<\/tr>\n
5<\/td>\nList of figures
List of tables <\/td>\n<\/tr>\n
6<\/td>\nSummary of pages <\/td>\n<\/tr>\n
7<\/td>\nIntroduction by Lee Brankley, CEO, CARES <\/td>\n<\/tr>\n
8<\/td>\nForeword
Publishing information
Supersession
Information about this document <\/td>\n<\/tr>\n
9<\/td>\nUse of this document
Presentational conventions
Contractual and legal considerations
Compliance with a British Standard cannot confer immunity from legal obligations. <\/td>\n<\/tr>\n
10<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
11<\/td>\n3 Terms, definitions and symbols
3.1 Terms and definitions
3.1.1 0.2% proof strength, Rp0.2
Key <\/td>\n<\/tr>\n
12<\/td>\n3.1.2 bar
3.1.2 cold worked ribbed bar
ribbed bar that has been cold worked to meet the property andgeometrical requirements of this British Standard
3.1.3 batch
3.1.4 bundle
3.1.5 cast (heat) analysis
3.1.6 characteristic value, Cv
3.1.7 characteristic yield strength, fyk
3.1.8 coil
3.1.9 cold worked ribbed stainless reinforcing steel bar
3.1.10 critical chloride threshold value
3.1.11 decoiled product <\/td>\n<\/tr>\n
13<\/td>\n3.1.3 hot rolled ribbed bar
3.1. 12 hot rolled ribbed stainless reinforcing steel bar
3.1.4 nominal diameter, d
3.1.13 length
3.1.14 longitudinal rib
3.1.15 manufacturer
3.1.16 maximum value
3.1.17 minimum value
3.1.18 nominal cross-sectional area, An
3.1.19 nominal diameter, d
3.1.53.1.20 coil product analysis
3.1.7 bundle
3.1.21 purchaser <\/td>\n<\/tr>\n
14<\/td>\n3.1.22 reinforcing steel
3.1.23 reinforcing steel designation
3.1.24 reinforcing steel grade
3.1.9
3.1.10 transverse rib
3.1.113.1. 26 rib height, a\u03b1max
3.1.133.1.28 relative rib area, fR stress ratio, \u03c3f
area of the projections of all ribs on a plane perpendicular to the longitudinal axis of the wire, or bar, or rod, divided by the wire length and the nominal circumference
3.1.1929 supplier
3.1.203.1.30 purchasertransverse rib
3.1.21 0.2 % proof strength, Rp0.2 <\/td>\n<\/tr>\n
15<\/td>\n3.1.14
3.1.15
transverse rib flank inclination, !
angle between the rib flank and the longitudinal axis of the bar (see Figure C.2)
3.1.16 cast (heat) analysis
3.1.17 product analysis
3.1.18 manufacturer
3.1.22 characteristic strength <\/td>\n<\/tr>\n
17<\/td>\n3.1.31 transverse rib flank inclination, \u03b1
3.1.32 transverse rib inclination, \u03b2
Figure 2 Typical stress-strain curve (relation) for stainless reinforcing <\/td>\n<\/tr>\n
20<\/td>\n4 Designation
EXAMPLE
5 Standard sizesdiameters <\/td>\n<\/tr>\n
21<\/td>\n6 Dimensions, mass and tolerances
6.1 EffectiveNominal cross-sectional area and mass per metre run <\/td>\n<\/tr>\n
22<\/td>\nTable 3 \u2014 Nominal cross-sectional area of reinforcing steel and nominal mass per metre run
Table 4 \u2014 Tolerances on mass per metre run <\/td>\n<\/tr>\n
23<\/td>\nTable 4 \u2014 Tolerances on mass per metre run
Table 4 Tolerances on mass per metre run
7 Steelmaking process
8 Chemical composition
8.1 Cast analysis <\/td>\n<\/tr>\n
24<\/td>\nTable 5 \u2014 Stainless steel bar chemical composition (cast analysis) % by mass <\/td>\n<\/tr>\n
25<\/td>\n8.2 Product analysis
9 Surface quality
10 Surface geometry
10.1 General <\/td>\n<\/tr>\n
26<\/td>\nTable 5 Chemical composition (cast analysis)% by mass of typical, commercially available BS EN 10088 stainless reinforcing steel designationsA)
10.2 Relative rib area <\/td>\n<\/tr>\n
27<\/td>\n10.3 Geometry of rib
10.3.1 General
10.3.2 Transverse ribs <\/td>\n<\/tr>\n
28<\/td>\n11 Conditions of supply
12 Mechanical and physical properties
12.1 Selection of test samples for conformity testing
12.2 Test reports
12.3 Test certificate <\/td>\n<\/tr>\n
29<\/td>\n12.4 Retests
12.5 Tensile properties
12.5.1 0.2% proof strength, Rp0.2
12.5.2 Tensile strength, Rm
12.5.3 Stress ratio, \u03c3f
12.5.4 Elongation at maximum force <\/td>\n<\/tr>\n
30<\/td>\n12.5.5 Percentage elongation after fracture, A5 <\/td>\n<\/tr>\n
31<\/td>\n12.1 Tensile properties
Table 8 Strength and ductility properties <\/td>\n<\/tr>\n
32<\/td>\n12.2 Total elongation at maximum force, Agt
12.6 Bendability
12.7 Bonding strength (surface geometry)
12.4 12. 8 Fatigue testcharacteristics <\/td>\n<\/tr>\n
33<\/td>\n12.9 Strength at elevated temperature (tensile strength)
12.10 Chemical composition and durability
12.11 Weldability
12.512.12 Additional test requirements
12.5.112.12.1 General
12.5.212.12.2 Charpy impact test
12.5.312.12.3 Intergranular corrosion test <\/td>\n<\/tr>\n
34<\/td>\nRetests
1413 Product identification
14.113.1 Product marking
14.213.2 Product labelling <\/td>\n<\/tr>\n
35<\/td>\nAnnex A
(normative)
A.1 Uniform cross-sectional area
A.2 Variable cross-sectional area <\/td>\n<\/tr>\n
36<\/td>\nAnnex B(informative)
Table B.1 \u2014 Guidance on the use of stainless steel reinforcement for different service conditions <\/td>\n<\/tr>\n
37<\/td>\nC.2 Test procedure (see Figure C.1 and Figure C.2)
C.2.1 Heights of transverse ribs
C.2.2 Height of longitudinal ribs, a\u00b4
C.2.3 Transverse rib or indentation spacing, c
C.2.4 Pitch, P
C.2.5 Transverse ribless perimeter, Cfi
C.2.6 Transverse rib angle,
C.2.7 Transverse rib flank inclination, !
C.3 Determination of the relative rib area, fR
C.3.1 General <\/td>\n<\/tr>\n
38<\/td>\nC.3.2 Calculation of fR (see Figure C.3)
C.3.3 Simplified formulae <\/td>\n<\/tr>\n
39<\/td>\nC.3.4 Formula used for the calculation of fR
Key <\/td>\n<\/tr>\n
40<\/td>\nFigure C.2 \u2014 Rib flank inclination, !, and rib height, a (section A-A from Figure C.1)
Figure C.3 \u2014 Determining the area of the longitudinal section of a rib <\/td>\n<\/tr>\n
41<\/td>\nA.1 Principle
A.2 Materials
A.2.1 Ribbed stainless reinforcing steel
A.2.2 Mortar
A.2.3 Specimens <\/td>\n<\/tr>\n
42<\/td>\nKey
A .2.4 Test procedure
A.2.5 Test results <\/td>\n<\/tr>\n
43<\/td>\nA.2.6 Test report <\/td>\n<\/tr>\n
44<\/td>\n(informative) D.1.1 Manufacturer’s inspection B.1 General
D.1.2 Selection of test samples
D.1.3 Condition of test samples
D.1.4 Tensile test
D.1.5 Test records
D.1.6 Test certificate <\/td>\n<\/tr>\n
46<\/td>\nB.2 Terminology
B.3 Prescriptive guidance
B.4 Performance guidance
B.4.1 General <\/td>\n<\/tr>\n
47<\/td>\nB.4.2 Performance guidance for carbonation induced corrosion. <\/td>\n<\/tr>\n
49<\/td>\nB.4.3 Performance guidance for chloride-induced corrosion
B.4.4 Performance guidance for chloride induced corrosion in carbonated concrete <\/td>\n<\/tr>\n
50<\/td>\nFigure B.1 Example predictive model indicating where carbon steel reinforcement can be replaced by stainless steel reinforcement for a given chloride surface content, design life and reinforcement depth <\/td>\n<\/tr>\n
51<\/td>\nB.5 Adaptations and limitations <\/td>\n<\/tr>\n
52<\/td>\nAnnex E (normative)
Bend test <\/td>\n<\/tr>\n
53<\/td>\nTable F.1 \u2014 Fatigue test stress ranges
F.3 Test procedure
F.4 Retests <\/td>\n<\/tr>\n
54<\/td>\nTable G.1 \u2014 Comparison between the designation systems used in current and former British Standards and American steel specifications <\/td>\n<\/tr>\n
56<\/td>\nAnnex I (informative)
Third party certification
I.1 Material covered by a third party product certification schemeI
I.1.2.1 Extent of testing
I.1.2.2 Evaluation <\/td>\n<\/tr>\n
57<\/td>\nAnnex D
Table D.1 Comparative thermal coefficient of expansion data <\/td>\n<\/tr>\n
58<\/td>\nFigure E.1 Idealized design curve from BS EN 1992-1-1:2004+A1:2014
Table E.1 Young\u2019s modulus for stainless reinforcing steel <\/td>\n<\/tr>\n
59<\/td>\nFigure E.2 The constitutive law of stainless reinforcing steel
E.2 Steps for using the full properties of higher strength and ductility of stainless reinforcing steel <\/td>\n<\/tr>\n
60<\/td>\nFigure E.3 Example of design model for stainless reinforcing steel <\/td>\n<\/tr>\n
61<\/td>\nF.2 Duplex stainless reinforcing steel
F.3 Welding stainless reinforcing steels to carbon steels
F.4 Handling and processing <\/td>\n<\/tr>\n
62<\/td>\n(normative) For N values for performance retention at elevated temperatures the relevant designation shall be selected from BS EN 1993-1-2:2005, Table C.1. <\/td>\n<\/tr>\n
63<\/td>\nH.1.2.1 Extent of testing
H.1.2.2 Evaluation <\/td>\n<\/tr>\n
64<\/td>\nTable H.1 Acceptability number of test results, n, for a reliable failure rate of 5% (pass = 0.95) at a probability of 90% (1 \u2013 \u03b1 = 0.90) <\/td>\n<\/tr>\n
66<\/td>\nI.2.2H.2.2 Extent of sampling and testing
I.2.3H.2.3 Properties to be tested <\/td>\n<\/tr>\n
67<\/td>\nc) Chemical composition according to product analysis:
d) Fatigue properties:
I.2.4H.2.4 Evaluation of results <\/td>\n<\/tr>\n
68<\/td>\nI .2.4.2H.2.4.2 Inspection by attributes
H.3 Corrosion testing <\/td>\n<\/tr>\n
69<\/td>\nAnnex JI (informative)
Table J.1 \u2014 Comparative thermal coefficient of expansion data <\/td>\n<\/tr>\n
70<\/td>\nBibliography
Standards publications
Other publications <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Tracked Changes. Stainless steel bars. Reinforcement of concrete. Requirements and test methods<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2020<\/td>\n117<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":294242,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1111,2641],"product_tag":[],"class_list":{"0":"post-294238","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-77-140-15","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/294238","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/294242"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=294238"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=294238"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=294238"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}