{"id":414112,"date":"2024-10-20T05:58:54","date_gmt":"2024-10-20T05:58:54","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d7215-6\/"},"modified":"2024-10-26T11:09:07","modified_gmt":"2024-10-26T11:09:07","slug":"astm-d7215-6","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d7215-6\/","title":{"rendered":"ASTM-D7215"},"content":{"rendered":"
Scope<\/strong><\/p>\n 1.1<\/span> This test method covers the calculated flash point formula, which represents a means for directly estimating the flash point temperature of distillate fuels from Test Method D2887<\/span> data. The value computed from the equation is termed the \u201ccalculated flash point.\u201d The calculated flash point formula is applicable to diesel fuel samples based on a correlation to Test Method D93<\/span> over the range from 47\u2009\u00b0C to 99\u2009\u00b0C, and to jet fuel samples based on a correlation to Test Method D56<\/span> and Test Method D3828<\/span> over the range from 35\u2009\u00b0C to 67\u2009\u00b0C.<\/p>\n<\/p><\/div>\n 1.2<\/span> The calculated flash point formula is valid for diesel and jet fuels with an IBP between 90\u2009\u00b0C and 162\u2009\u00b0C (194\u2009\u00b0F and 324\u2009\u00b0F), Test Method D2887<\/span> 5\u2009% recovery temperature between 136\u2009\u00b0C and 207\u2009\u00b0C (277\u2009\u00b0F and 405\u2009\u00b0F), and Test Method D2887<\/span> 10\u2009% recovery temperature between 142\u2009\u00b0C and 222\u2009\u00b0C (288\u2009\u00b0F and 432\u2009\u00b0F). For each flash point test method (Test Method D56<\/span>, Test Method D93<\/span>, and Test Method D3828<\/span>) a separate equation has been established. See 4.4<\/span> for a detailed overview of the simulated distillation IBP, 5\u2009%, and 10\u2009% ranges per equation.<\/p>\n<\/p><\/div>\n 1.3<\/span> A calculated diagnostic parameter, not exceeding a given threshold value, is a prerequisite for acceptance of the calculated flash point.<\/p>\n<\/p><\/div>\n 1.4<\/span> The diagnostic parameter MSPEX<\/span><\/sub>\u2009 (Mean Summed Prediction Error) checks the sample compliance, based on reconstruction of TIBP<\/span><\/sub>, T5\u2009%<\/span><\/sub>, and T10\u2009%<\/span><\/sub> of the sample, via a calculation procedure. A value for MSPEX<\/span><\/sub> not exceeding the threshold level of 1.9\u2009\u00b0C is a prerequisite for accepting the calculated flash point, CFP.<\/p>\n Note 1:<\/span> It is important to note that calculated flash point results, at this time, are not recognized by regulatory organizations in verifying conformance to applicable regulations.<\/span><\/p>\n<\/p><\/div>\n Note 2:<\/span> The calculated flash point derived from simulated distillation data depends upon the accuracy of determination of the IBP temperature and the 5\u2009% and 10\u2009% recovery temperatures.<\/span><\/p>\n<\/p><\/div>\n Note 3:<\/span> If the user’s specification requires a defined flash point test method other than this test method, neither this test method nor any other test method should be substituted for the prescribed test method without obtaining comparative data and an agreement from the specifier.<\/span><\/p>\n<\/p><\/div>\n<\/p><\/div>\n 1.5<\/span> The values stated in SI units are to be regarded as the standard.<\/p>\n 1.5.1<\/span> Exception\u2014<\/span>The values given in parentheses are for information only.<\/p>\n<\/p><\/div>\n<\/p><\/div>\n 1.6<\/span> This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.<\/i><\/p>\n<\/p><\/div>\n 1.7<\/span> This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.<\/i><\/p>\n<\/p><\/div>\n Keywords<\/strong><\/p>\n calculated flash point; diesel fuel; flash point; jet fuel; MSPEX; PLS; simulated distillation;<\/p>\n ICS Code<\/strong><\/p>\n ICS Number Code 75.160.20 (Liquid fuels)<\/p>\n DOI:<\/strong> 10.1520\/D7215-22<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":" D7215-22 Standard Test Method for Calculated Flash Point from Simulated Distillation Analysis of Distillate Fuels<\/b><\/p>\n\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2022<\/td>\n <\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":414119,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1074,2637],"product_tag":[],"class_list":{"0":"post-414112","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-75-160-20","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/414112","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/414119"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=414112"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=414112"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=414112"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}