{"id":449509,"date":"2024-10-20T09:03:17","date_gmt":"2024-10-20T09:03:17","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ashrae-designing-for-operational-excellence-2022\/"},"modified":"2024-10-26T16:55:27","modified_gmt":"2024-10-26T16:55:27","slug":"ashrae-designing-for-operational-excellence-2022","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ashrae\/ashrae-designing-for-operational-excellence-2022\/","title":{"rendered":"ASHRAE Designing For Operational Excellence 2022"},"content":{"rendered":"

Operational excellence is the result of consistent and reliable building performance that optimizes the total cost of ownership, minimizes environmental impact, and yields maximum beneficial use to both the building\u2019s owner and its occupants. In application, operational excellence is the culmination of an effectively operated building environment, yielding the utmost efficiencies of well-designed and well-constructed systems that result in the maximized use of a building at the minimum level of wasted resources. Design enables operational excellence by providing the foundational structure and systems to effectively serve a building\u2019s needs. Designers have the unique ability to impact the long-term operation of a building through integrated and thoughtfully designed systems. As the planning, design, and construction of any particular structure represents only a fraction of the life-cycle cost of a building, it is critical that the design is informed and intentional to provide adequate maintenance capabilities and operational efficiencies over the entire life of the building systems. Major advances have been made in the technology related to building equipment and control systems, but there is still a large gap between the designed, expected operation and the actual operation of a building. This gap impacts the indoor environmental quality and the energy use of many buildings around the world. Designing for Operational Excellence helps bring operations to the forefront of the design process, enabling designers to design buildings and systems that focus on long-term operational excellence and detailing the process and considerations for incorporating operational excellence into any building\u2019s design. The guide gives building owners, designers, commissioning providers, and building operators the guidance they need to understand the operational needs of buildings, to design and operate systems in this environment, and to provide safe, comfortable, efficient, and affordable conditions in the built environment.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
6<\/td>\nABOUT THE AUTHORS <\/td>\n<\/tr>\n
8<\/td>\nCONTENTS <\/td>\n<\/tr>\n
9<\/td>\nLIST OF CASE STUDIES <\/td>\n<\/tr>\n
10<\/td>\nFOREWORD <\/td>\n<\/tr>\n
12<\/td>\nPREFACE AND ACKNOWLEDGMENTS <\/td>\n<\/tr>\n
14<\/td>\n1 – INTRODUCTION
OPERATIONAL EXCELLENCE DEFINED
THE IMPACT OF DESIGN ON OPERATIONAL EXCELLENCE <\/td>\n<\/tr>\n
15<\/td>\nMEASURING OPERATIONAL EXCELLENCE WITH KEY PERFORMANCE INDICATORS
GLOSSARY <\/td>\n<\/tr>\n
16<\/td>\n2 – SETTING PROJECT GOALS <\/td>\n<\/tr>\n
17<\/td>\nOWNER\u2019S PROJECT REQUIREMENTS <\/td>\n<\/tr>\n
19<\/td>\nKEY PERFORMANCE INDICATORS <\/td>\n<\/tr>\n
20<\/td>\n3 – DECISION MAKING BASED ON TOTAL COST OF OWNERSHIP
TOTAL COST OF OWNERSHIP
LIFE-CYCLE COST ANALYSIS <\/td>\n<\/tr>\n
21<\/td>\nCOSTS INCLUDED IN LCCA <\/td>\n<\/tr>\n
22<\/td>\nSCALING LCCA TO THE PROJECT <\/td>\n<\/tr>\n
23<\/td>\nLCCA EXAMPLES <\/td>\n<\/tr>\n
26<\/td>\n4 – CONSTRUCTION BUDGETING AND PROJECT FUNDING <\/td>\n<\/tr>\n
27<\/td>\nCONTINUOUS BUDGETING PROCESS <\/td>\n<\/tr>\n
28<\/td>\nOPERATIONAL BUDGET ESTIMATE
PROJECT FUNDING AND FINANCING
ENERGY EFFICIENCY MEASURES <\/td>\n<\/tr>\n
30<\/td>\n5 – EVALUATING THE APPLICATION OF INNOVATIVE TECHNOLOGIES
APPLICABILITY <\/td>\n<\/tr>\n
31<\/td>\nCOST IMPACT
CONSTRUCTION IMPACT <\/td>\n<\/tr>\n
32<\/td>\nRELIABILITY <\/td>\n<\/tr>\n
33<\/td>\nOPERATIONAL KNOWLEDGE
QUESTIONS TO ASK <\/td>\n<\/tr>\n
34<\/td>\n6 – COLLABORATION AND COORDINATION
CONSTRUCTABILITY <\/td>\n<\/tr>\n
35<\/td>\nCONSIDERATIONS FOR CONSTRUCTABILITY
MAINTAINABILITY <\/td>\n<\/tr>\n
36<\/td>\nDESIGN PRINCIPLES FOR MAINTAINABILITY <\/td>\n<\/tr>\n
38<\/td>\nBUILDING INFORMATION MODELING <\/td>\n<\/tr>\n
39<\/td>\nCOORDINATION <\/td>\n<\/tr>\n
40<\/td>\nCLOUD-BASED COLLABORATION <\/td>\n<\/tr>\n
41<\/td>\nDIGITAL TWIN
BIM FOR OPERATIONS <\/td>\n<\/tr>\n
42<\/td>\nAUGMENTED REALITY <\/td>\n<\/tr>\n
44<\/td>\n7 – BENCHMARKING
OPERATIONS AND MAINTENANCE BENCHMARKING
METRICS TO BENCHMARK <\/td>\n<\/tr>\n
46<\/td>\nHOW TO BENCHMARK
ENERGY BENCHMARKING <\/td>\n<\/tr>\n
48<\/td>\n8 – COMMISSIONING
TYPES OF COMMISSIONING <\/td>\n<\/tr>\n
49<\/td>\nSTANDARDS AND BEST PRACTICES <\/td>\n<\/tr>\n
50<\/td>\nWORKING WITH THE NEW CONSTRUCTIONCOMMISSIONING PROVIDER <\/td>\n<\/tr>\n
54<\/td>\n9 – TRANSITION TO OPERATIONS
OPERATOR TRAINING <\/td>\n<\/tr>\n
56<\/td>\nCOMPUTERIZED MAINTENANCEMANAGEMENT SYSTEM <\/td>\n<\/tr>\n
58<\/td>\nRESOLVING CONSTRUCTION ISSUES <\/td>\n<\/tr>\n
60<\/td>\n10 – ENVIRONMENTAL IMPACT
EFFORTS TO MINIMIZE ENERGYAND POWER NEEDS <\/td>\n<\/tr>\n
61<\/td>\nREDUCING ATMOSPHERIC EMISSIONSDUE TO ENERGY PRODUCTION <\/td>\n<\/tr>\n
62<\/td>\nWATER CONSERVATION <\/td>\n<\/tr>\n
64<\/td>\nSOLID AND LIQUID WASTE DISPOSAL
REFRIGERANTS <\/td>\n<\/tr>\n
65<\/td>\nSUMMARY <\/td>\n<\/tr>\n
66<\/td>\n11 – OCCUPANT SATISFACTION
THERMAL COMFORT <\/td>\n<\/tr>\n
67<\/td>\nAIR TEMPERATURE (DRY BULB) <\/td>\n<\/tr>\n
68<\/td>\nRELATIVE HUMIDITY <\/td>\n<\/tr>\n
69<\/td>\nINDOOR ENVIRONMENTAL QUALITY <\/td>\n<\/tr>\n
70<\/td>\nOTHER CONSIDERATIONS <\/td>\n<\/tr>\n
73<\/td>\nMEASURING OCCUPANT SATISFACTION <\/td>\n<\/tr>\n
76<\/td>\n12 – FIRE SAFETY AND REGULATORY COMPLIANCE
PATHS OF EGRESS
FIRE SAFETY DESIGN <\/td>\n<\/tr>\n
79<\/td>\nELEVATOR SYSTEMS <\/td>\n<\/tr>\n
80<\/td>\n13 – RESILIENCY AND REDUNDANCY
RESILIENCY <\/td>\n<\/tr>\n
81<\/td>\nREDUNDANCY <\/td>\n<\/tr>\n
83<\/td>\nDATA CENTERS <\/td>\n<\/tr>\n
85<\/td>\nSUMMARY <\/td>\n<\/tr>\n
86<\/td>\n14 – ENERGY EFFICIENCY
MECHANICAL SYSTEM CONSIDERATIONS <\/td>\n<\/tr>\n
89<\/td>\nEXISTING BUILDING CONSIDERATIONS <\/td>\n<\/tr>\n
90<\/td>\n15 – BUILDING AUTOMATION SYSTEM <\/td>\n<\/tr>\n
91<\/td>\nSYSTEM ARCHITECTURE
SEQUENCES OF OPERATION
POINT NAMING <\/td>\n<\/tr>\n
92<\/td>\nGRAPHIC USER INTERFACE
POINT TO POINT CHECKOUT <\/td>\n<\/tr>\n
94<\/td>\n16 – MEASUREMENT AND VERIFICATION
ASHRAE GUIDELINE 14 <\/td>\n<\/tr>\n
95<\/td>\nINTERNATIONAL PERFORMANCE MEASUREMENTAND VERIFICATION PROTOCOL <\/td>\n<\/tr>\n
96<\/td>\nM&V PLAN
ACCURACY
EXECUTION <\/td>\n<\/tr>\n
98<\/td>\n17 – FAULT DETECTION AND DIAGNOSTICS <\/td>\n<\/tr>\n
99<\/td>\nFAULTS DEFINED <\/td>\n<\/tr>\n
100<\/td>\nMETHODS FOR IMPLEMENTING FDD <\/td>\n<\/tr>\n
101<\/td>\nCONSIDERATIONS <\/td>\n<\/tr>\n
102<\/td>\n18 – CONCLUSION <\/td>\n<\/tr>\n
104<\/td>\nREFERENCES AND BIBLIOGRAPHY
REFERENCES <\/td>\n<\/tr>\n
107<\/td>\nBIBLIOGRAPHY <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Designing for Operational Excellence — Intentional Design for Effective Operation and Maintenance<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASHRAE<\/b><\/a><\/td>\n2022<\/td>\n110<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":449510,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2719],"product_tag":[],"class_list":{"0":"post-449509","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ashrae","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/449509","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/449510"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=449509"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=449509"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=449509"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}